... ... @@ -662,16 +662,15 @@
662 662  
663 663  ==== **RS485 command timeout** ====
664 664  
665 -Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action.
665 +Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action.
666 666  
667 -Default value: 0, range:  0 ~~ 5 seconds
667 +Default value: 0, range:  0 ~~ 65 seconds
668 668  
669 -
670 670  * **AT Command:**
671 671  
672 672  (% class="box infomessage" %)
673 673  (((
674 -**AT+CMDDLaa=hex(bb cc)**
673 +**AT+CMDDLaa=hex(bb cc)*1000**
675 675  )))
676 676  
677 677  **Example:**
... ... @@ -681,13 +681,13 @@
681 681  
682 682  * **Downlink Payload:**
683 683  
684 -0x AA aa bb cc
683 +**0x AA aa bb cc**
685 685  
686 -Same as: AT+CMDDLaa=hex(bb cc)
685 +Same as: AT+CMDDLaa=hex(bb cc)*1000
687 687  
688 688   **Example:**
689 689  
690 - **0xAA 01 03 E8**  ~-~-> Same as **AT+CMDDL1=1000 ms**
689 + 0xAA 01 00 01  ~-~-> Same as **AT+CMDDL1=1000 ms**
691 691  
692 692  
693 693  
... ... @@ -722,27 +722,34 @@
722 722  
723 723  Ask device to send an uplink immediately.
724 724  
724 +* **AT Command:**
725 +
726 +No AT Command for this, user can press the [[ACT button>>path:#Button]] for 1 second for the same.
727 +
728 +
725 725  * **Downlink Payload:**
726 726  
727 -**0x08 FF**, RS485-BL will immediately send an uplink.
731 +**0x08 FF**, RS485-LN will immediately send an uplink.
728 728  
729 729  
734 +==== ====
730 730  
731 731  ==== **Clear RS485 Command** ====
732 732  
733 733  The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
734 734  
735 -
736 736  * **AT Command:**
737 737  
738 -(% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
742 +**AT+CMDEAR=mm,nn**   mm: start position of erase ,nn: stop position of erase
739 739  
740 -Example screen shot after clear all RS485 commands. 
744 +Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
741 741  
746 +Example screen shot after clear all RS485 commands.
742 742  
748 +
743 743  The uplink screen shot is:
744 744  
745 -[[image:1654134704555-320.png]]
751 +[[image:1654160691922-496.png]][[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]]
746 746  
747 747  
748 748  * **Downlink Payload:**
... ... @@ -794,21 +794,4 @@
794 794  
795 795  
796 796  
797 -==== **Control output power duration** ====
798 -
799 -User can set the output power duration before each sampling.
800 -
801 -* **AT Command:**
802 -
803 -**Example:**
804 -
805 -**AT+3V3T=1000**  ~/~/ 3V3 output power will open 1s before each sampling.
806 -
807 -**AT+5VT=1000**  ~/~/ +5V output power will open 1s before each sampling.
808 -
809 -
810 -* **LoRaWAN Downlink Command:**
811 -
812 -**07 01 aa bb**  Same as AT+5VT=(aa bb)
813 -
814 -**07 02 aa bb**  Same as AT+3V3T=(aa bb)
803 +==== ====
1654160691922-496.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +109.3 KB
Content
image-20220602171200-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +276.1 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0