Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Karry Zhuang on 2025/03/06 16:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -662,16 +662,15 @@ 662 662 663 663 ==== **RS485 command timeout** ==== 664 664 665 -Some Modbus device has slow action to send replies. This command is used to configure the RS485- BL to use longer time to wait for their action.665 +Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action. 666 666 667 -Default value: 0, range: 0 ~~ 5 seconds 667 +Default value: 0, range: 0 ~~ 65 seconds 668 668 669 - 670 670 * **AT Command:** 671 671 672 672 (% class="box infomessage" %) 673 673 ((( 674 -**AT+CMDDLaa=hex(bb cc)** 673 +**AT+CMDDLaa=hex(bb cc)*1000** 675 675 ))) 676 676 677 677 **Example:** ... ... @@ -681,13 +681,13 @@ 681 681 682 682 * **Downlink Payload:** 683 683 684 -0x AA aa bb cc 683 +**0x AA aa bb cc** 685 685 686 -Same as: AT+CMDDLaa=hex(bb cc) 685 +Same as: AT+CMDDLaa=hex(bb cc)*1000 687 687 688 688 **Example:** 689 689 690 - **0xAA 01 03E8**~-~-> Same as **AT+CMDDL1=1000 ms**689 + 0xAA 01 00 01 ~-~-> Same as **AT+CMDDL1=1000 ms** 691 691 692 692 693 693 ... ... @@ -722,17 +722,47 @@ 722 722 723 723 Ask device to send an uplink immediately. 724 724 724 +* **AT Command:** 725 + 726 +No AT Command for this, user can press the [[ACT button>>path:#Button]] for 1 second for the same. 727 + 728 + 725 725 * **Downlink Payload:** 726 726 727 -**0x08 FF**, RS485- BL will immediately send an uplink.731 +**0x08 FF**, RS485-LN will immediately send an uplink. 728 728 729 729 734 +==== ==== 730 730 731 731 ==== **Clear RS485 Command** ==== 732 732 733 733 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 734 734 740 +* **AT Command:** 735 735 742 +**AT+CMDEAR=mm,nn** mm: start position of erase ,nn: stop position of erase 743 + 744 +Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 745 + 746 +Example screen shot after clear all RS485 commands. 747 + 748 + 749 +The uplink screen shot is: 750 + 751 +[[image:1654160691922-496.png]][[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]] 752 + 753 + 754 +* **Downlink Payload:** 755 + 756 +**0x09 aa bb** same as AT+CMDEAR=aa,bb 757 + 758 + 759 + 760 +==== **Clear RS485 Command** ==== 761 + 762 +The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 763 + 764 + 736 736 * **AT Command:** 737 737 738 738 (% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
- 1654160691922-496.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +109.3 KB - Content