663 663  ==== **RS485 command timeout** ====
664 664  
665 -Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action.
665 +Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action.
666 666  
667 -Default value: 0, range:  0 ~~ 5 seconds
667 +Default value: 0, range:  0 ~~ 65 seconds
668 668  
669 -
670 670  * **AT Command:**
671 671  
672 672  (% class="box infomessage" %)
673 673  (((
674 -**AT+CMDDLaa=hex(bb cc)**
673 +**AT+CMDDLaa=hex(bb cc)*1000**
675 675  )))
676 676  
677 677  **Example:**
... ... @@ -681,13 +681,13 @@
681 681  
682 682  * **Downlink Payload:**
683 683  
684 -0x AA aa bb cc
683 +**0x AA aa bb cc**
685 685  
686 -Same as: AT+CMDDLaa=hex(bb cc)
685 +Same as: AT+CMDDLaa=hex(bb cc)*1000
687 687  
688 688   **Example:**
689 689  
690 - **0xAA 01 03 E8**  ~-~-> Same as **AT+CMDDL1=1000 ms**
689 + 0xAA 01 00 01  ~-~-> Same as **AT+CMDDL1=1000 ms**
691 691  
692 692  
693 693  