Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Karry Zhuang on 2025/03/06 16:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -585,7 +585,6 @@ 585 585 **AT+PAYVER: Set PAYVER field = 1** 586 586 ))) 587 587 588 - 589 589 * **Downlink Payload:** 590 590 591 591 **0xAE 01** ~-~-> Set PAYVER field = 0x01 ... ... @@ -596,9 +596,9 @@ 596 596 597 597 ==== **Set RS485 Sampling Commands** ==== 598 598 599 -AT+COMMANDx ,AT+DATACUTxand AT+SEARCHx598 +AT+COMMANDx or AT+DATACUTx 600 600 601 -These three commands are used to configure how the RS485- BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].600 +These three commands are used to configure how the RS485-LN polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 602 602 603 603 604 604 * **AT Command:** ... ... @@ -613,12 +613,7 @@ 613 613 **AT+DATACUTx: Configure how to handle return from RS485 devices.** 614 614 ))) 615 615 616 -(% class="box infomessage" %) 617 -((( 618 -**AT+SEARCHx: Configure search command** 619 -))) 620 620 621 - 622 622 * **Downlink Payload:** 623 623 624 624 **0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx. ... ... @@ -633,7 +633,7 @@ 633 633 * NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 634 634 * LL: The length of AT+COMMAND or AT+DATACUT command 635 635 * XX XX XX XX: AT+COMMAND or AT+DATACUT command 636 -* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485- BL will execute an uplink after got this command.630 +* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-LN will execute an uplink after got this command. 637 637 638 638 **Example:** 639 639 ... ... @@ -644,17 +644,7 @@ 644 644 (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10** 645 645 646 646 647 -**0xAB** downlink command can be used for set AT+SEARCHx 648 648 649 -**Example:** **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So 650 - 651 -* AB aa 01 03 xx xx xx same as AT+SEARCHaa=1,xx xx xx 652 -* AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands 653 - 654 -**AB aa 02 03 xx xx xx 02 yy yy** same as **AT+SEARCHaa=2,xx xx xx+yy yy** 655 - 656 - 657 - 658 658 ==== **Fast command to handle MODBUS device** ==== 659 659 660 660 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. ... ... @@ -661,45 +661,32 @@ 661 661 662 662 This command is valid since v1.3 firmware version 663 663 648 +AT+MBFUN can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 664 664 665 -**AT+MBFUN has only two value:** 666 666 667 -* **AT+MBFUN=1**: Enable Modbus reading. And get response base on the MODBUS return 668 - 669 -AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 670 - 671 -* **AT+MBFUN=0**: Disable Modbus fast reading. 672 - 673 673 **Example:** 674 674 675 -* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). 653 +* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). So RS485-LN. 676 676 * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 677 677 * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 678 678 679 -[[image:165 4133913295-597.png]]657 +[[image:image-20220602165351-6.png]] 680 680 659 +[[image:image-20220602165351-7.png]] 681 681 682 -[[image:1654133954153-643.png]] 683 683 684 684 685 -* **Downlink Commands:** 686 - 687 -**A9 aa** ~-~-> Same as AT+MBFUN=aa 688 - 689 - 690 - 691 691 ==== **RS485 command timeout** ==== 692 692 693 -Some Modbus device has slow action to send replies. This command is used to configure the RS485- BL to use longer time to wait for their action.665 +Some Modbus device has slow action to send replies. This command is used to configure the RS485-LN to use longer time to wait for their action. 694 694 695 -Default value: 0, range: 0 ~~ 5 seconds 667 +Default value: 0, range: 0 ~~ 65 seconds 696 696 697 - 698 698 * **AT Command:** 699 699 700 700 (% class="box infomessage" %) 701 701 ((( 702 -**AT+CMDDLaa=hex(bb cc)** 673 +**AT+CMDDLaa=hex(bb cc)*1000** 703 703 ))) 704 704 705 705 **Example:** ... ... @@ -709,13 +709,13 @@ 709 709 710 710 * **Downlink Payload:** 711 711 712 -0x AA aa bb cc 683 +**0x AA aa bb cc** 713 713 714 -Same as: AT+CMDDLaa=hex(bb cc) 685 +Same as: AT+CMDDLaa=hex(bb cc)*1000 715 715 716 716 **Example:** 717 717 718 - **0xAA 01 03E8**~-~-> Same as **AT+CMDDL1=1000 ms**689 + 0xAA 01 00 01 ~-~-> Same as **AT+CMDDL1=1000 ms** 719 719 720 720 721 721 ... ... @@ -750,17 +750,47 @@ 750 750 751 751 Ask device to send an uplink immediately. 752 752 724 +* **AT Command:** 725 + 726 +No AT Command for this, user can press the [[ACT button>>path:#Button]] for 1 second for the same. 727 + 728 + 753 753 * **Downlink Payload:** 754 754 755 -**0x08 FF**, RS485- BL will immediately send an uplink.731 +**0x08 FF**, RS485-LN will immediately send an uplink. 756 756 757 757 734 +==== ==== 758 758 759 759 ==== **Clear RS485 Command** ==== 760 760 761 761 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 762 762 740 +* **AT Command:** 763 763 742 +**AT+CMDEAR=mm,nn** mm: start position of erase ,nn: stop position of erase 743 + 744 +Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 745 + 746 +Example screen shot after clear all RS485 commands. 747 + 748 + 749 +The uplink screen shot is: 750 + 751 +[[image:1654160691922-496.png]][[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]] 752 + 753 + 754 +* **Downlink Payload:** 755 + 756 +**0x09 aa bb** same as AT+CMDEAR=aa,bb 757 + 758 + 759 + 760 +==== **Clear RS485 Command** ==== 761 + 762 +The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 763 + 764 + 764 764 * **AT Command:** 765 765 766 766 (% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
- 1654160691922-496.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +109.3 KB - Content
- image-20220602165351-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.6 KB - Content
- image-20220602165351-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +19.3 KB - Content