Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Karry Zhuang on 2025/03/06 16:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 8 removed)
Details
- Page properties
-
- Content
-
... ... @@ -76,6 +76,8 @@ 76 76 * Automatic RF Sense and CAD with ultra-fast AFC. 77 77 * Packet engine up to 256 bytes with CRC. 78 78 79 + 80 + 79 79 == 1.3 Features == 80 80 81 81 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -87,6 +87,8 @@ 87 87 * Support Modbus protocol 88 88 * Support Interrupt uplink (Since hardware version v1.2) 89 89 92 + 93 + 90 90 == 1.4 Applications == 91 91 92 92 * Smart Buildings & Home Automation ... ... @@ -96,6 +96,8 @@ 96 96 * Smart Cities 97 97 * Smart Factory 98 98 103 + 104 + 99 99 == 1.5 Firmware Change log == 100 100 101 101 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] ... ... @@ -216,8 +216,6 @@ 216 216 217 217 ((( 218 218 (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1 219 - 220 - 221 221 ))) 222 222 ))) 223 223 ... ... @@ -225,19 +225,19 @@ 225 225 226 226 To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are: 227 227 228 -(% border="1" style="background-color:#ffffcc; color:green; width:7 82px" %)229 -|( % style="width:128px" %)(((232 +(% border="1" style="background-color:#ffffcc; color:green; width:795px" %) 233 +|((( 230 230 **AT Commands** 231 -)))|(% style="width: 305px" %)(((235 +)))|(% style="width:285px" %)((( 232 232 **Description** 233 -)))|(% style="width:34 6px" %)(((237 +)))|(% style="width:347px" %)((( 234 234 **Example** 235 235 ))) 236 -|( % style="width:128px" %)(((240 +|((( 237 237 AT+BAUDR 238 -)))|(% style="width: 305px" %)(((242 +)))|(% style="width:285px" %)((( 239 239 Set the baud rate (for RS485 connection). Default Value is: 9600. 240 -)))|(% style="width:34 6px" %)(((244 +)))|(% style="width:347px" %)((( 241 241 ((( 242 242 AT+BAUDR=9600 243 243 ))) ... ... @@ -246,11 +246,11 @@ 246 246 Options: (1200,2400,4800,14400,19200,115200) 247 247 ))) 248 248 ))) 249 -|( % style="width:128px" %)(((253 +|((( 250 250 AT+PARITY 251 -)))|(% style="width: 305px" %)(((255 +)))|(% style="width:285px" %)((( 252 252 Set UART parity (for RS485 connection) 253 -)))|(% style="width:34 6px" %)(((257 +)))|(% style="width:347px" %)((( 254 254 ((( 255 255 AT+PARITY=0 256 256 ))) ... ... @@ -259,9 +259,9 @@ 259 259 Option: 0: no parity, 1: odd parity, 2: even parity 260 260 ))) 261 261 ))) 262 -|( % style="width:128px" %)(((266 +|((( 263 263 AT+STOPBIT 264 -)))|(% style="width: 305px" %)(((268 +)))|(% style="width:285px" %)((( 265 265 ((( 266 266 Set serial stopbit (for RS485 connection) 267 267 ))) ... ... @@ -269,7 +269,7 @@ 269 269 ((( 270 270 271 271 ))) 272 -)))|(% style="width:34 6px" %)(((276 +)))|(% style="width:347px" %)((( 273 273 ((( 274 274 AT+STOPBIT=0 for 1bit 275 275 ))) ... ... @@ -304,34 +304,77 @@ 304 304 === 3.3.3 Configure read commands for each sampling === 305 305 306 306 ((( 307 -During each sampling, we need confirm what commands we need to send to the RS485 sensors to read data. After the RS485 sensors send back the value, it normally include some bytes and we only need a few from them for a shorten payload. 311 +RS485-BL is a battery powered device; it will sleep most of time. And wake up on each period and read RS485 / TTL sensor data and uplink. 312 +))) 308 308 314 +((( 315 +During each sampling, we need to confirm what commands we need to send to the sensors to read data. After the RS485/TTL sensors send back the value, it normally includes some bytes and we only need a few from them for a shorten payload. 316 +))) 317 + 318 +((( 309 309 To save the LoRaWAN network bandwidth, we might need to read data from different sensors and combine their valid value into a short payload. 320 +))) 310 310 322 +((( 311 311 This section describes how to achieve above goals. 324 +))) 312 312 313 -During each sampling, the RS485-LN can support 15 commands to read sensors. And combine the return to one or several uplink payloads. 326 +((( 327 +During each sampling, the RS485-BL can support 15 commands to read sensors. And combine the return to one or several uplink payloads. 328 +))) 314 314 330 +((( 331 +**Command from RS485-BL to Sensor:** 332 +))) 315 315 316 -**Each RS485 commands include two parts:** 334 +((( 335 +RS485-BL can send out pre-set max 15 strings via **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF** . All commands are of same grammar. 336 +))) 317 317 318 -~1. What commands RS485-LN will send to the RS485 sensors. There are total 15 commands from **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF**. All commands are of same grammar. 338 +((( 339 +**Handle return from sensors to RS485-BL**: 340 +))) 319 319 320 -2. How to get wanted value the from RS485 sensors returns from by 1). There are total 15 AT Commands to handle the return, commands are **AT+DATACUT1**,**AT+DATACUT2**,…, **AT+DATACUTF** corresponding to the commands from 1). All commands are of same grammar. 342 +((( 343 +After RS485-BL send out a string to sensor, RS485-BL will wait for the return from RS485 or TTL sensor. And user can specify how to handle the return, by **AT+DATACUT or AT+SEARCH commands** 344 +))) 321 321 322 -3. Some RS485 device might has longer delay on reply, so user can use AT+CMDDL to set the timeout for getting reply after the RS485 command is sent. For example **AT+CMDDL1=1000** to send the open time to 1000ms 346 +* ((( 347 +**AT+DATACUT** 348 +))) 323 323 350 +((( 351 +When the return value from sensor have fix length and we know which position the valid value we should get, we can use AT+DATACUT command. 352 +))) 324 324 354 +* ((( 355 +**AT+SEARCH** 356 +))) 357 + 358 +((( 359 +When the return value from sensor is dynamic length and we are not sure which bytes the valid data is, instead, we know what value the valid value following. We can use AT+SEARCH to search the valid value in the return string. 360 +))) 361 + 362 +((( 363 +**Define wait timeout:** 364 +))) 365 + 366 +((( 367 +Some RS485 device might has longer delay on reply, so user can use AT+CMDDL to set the timeout for getting reply after the RS485 command is sent. For example, AT+CMDDL1=1000 to send the open time to 1000ms 368 +))) 369 + 370 +((( 325 325 After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**. 372 +))) 326 326 374 +**Examples:** 327 327 328 328 Below are examples for the how above AT Commands works. 329 329 378 +**AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is: 330 330 331 -**AT+COMMANDx : **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is: 332 - 333 -(% border="1" style="background-color:#4bacc6; color:white; width:499px" %) 334 -|(% style="width:496px" %)((( 380 +(% border="1" class="table-bordered" %) 381 +|((( 335 335 **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m** 336 336 337 337 **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent** ... ... @@ -339,15 +339,49 @@ 339 339 **m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command** 340 340 ))) 341 341 389 +((( 342 342 For example, if we have a RS485 sensor. The command to get sensor value is: 01 03 0B B8 00 02 46 0A. Where 01 03 0B B8 00 02 is the Modbus command to read the register 0B B8 where stored the sensor value. The 46 0A is the CRC-16/MODBUS which calculate manually. 391 +))) 343 343 344 -In the RS485-LN, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same. 393 +((( 394 +In the RS485-BL, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same. 395 +))) 345 345 397 +((( 398 +**AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx. 399 +))) 346 346 401 +(% border="1" class="table-bordered" %) 402 +|((( 403 +**AT+SEARCHx=aa,xx xx xx xx xx** 404 + 405 +* **aa: 1: prefix match mode; 2: prefix and suffix match mode** 406 +* **xx xx xx xx xx: match string. Max 5 bytes for prefix and 5 bytes for suffix** 407 + 408 + 409 +))) 410 + 411 +**Examples:** 412 + 413 +~1. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 414 + 415 +If we set AT+SEARCH1=1,1E 56 34. (max 5 bytes for prefix) 416 + 417 +The valid data will be all bytes after 1E 56 34 , so it is (% style="background-color:yellow" %)** 2e 30 58 5f 36 41 30 31 00 49** 418 + 419 +[[image:1653269403619-508.png]] 420 + 421 +2. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 422 + 423 +If we set AT+SEARCH1=2, 1E 56 34+31 00 49 424 + 425 +Device will search the bytes between 1E 56 34 and 31 00 49. So it is (% style="background-color:yellow" %)** 2e 30 58 5f 36 41 30** 426 + 427 +[[image:1653269438444-278.png]] 428 + 347 347 **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes. 348 348 349 -(% border="1" style="background-color:#4bacc6; color:white; width:725px" %) 350 -|(% style="width:722px" %)((( 431 +|((( 351 351 **AT+DATACUTx=a,b,c** 352 352 353 353 * **a: length for the return of AT+COMMAND** ... ... @@ -355,37 +355,48 @@ 355 355 * **c: define the position for valid value. ** 356 356 ))) 357 357 358 - **Examples:**439 +Examples: 359 359 360 360 * Grab bytes: 361 361 362 -[[image: image-20220602153621-1.png]]443 +[[image:1653269551753-223.png||height="311" width="717"]] 363 363 364 - 365 365 * Grab a section. 366 366 367 -[[image: image-20220602153621-2.png]]447 +[[image:1653269568276-930.png||height="325" width="718"]] 368 368 369 - 370 370 * Grab different sections. 371 371 372 -[[image: image-20220602153621-3.png]]451 +[[image:1653269593172-426.png||height="303" width="725"]] 373 373 374 - 375 -))) 453 +(% style="color:red" %)**Note:** 376 376 455 +AT+SEARCHx and AT+DATACUTx can be used together, if both commands are set, RS485-BL will first process AT+SEARCHx on the return string and get a temporary string, and then process AT+DATACUTx on this temporary string to get the final payload. In this case, AT+DATACUTx need to set to format AT+DATACUTx=0,xx,xx where the return bytes set to 0. 456 + 457 +Example: 458 + 459 +(% style="color:red" %)AT+COMMAND1=11 01 1E D0,0 460 + 461 +(% style="color:red" %)AT+SEARCH1=1,1E 56 34 462 + 463 +(% style="color:red" %)AT+DATACUT1=0,2,1~~5 464 + 465 +(% style="color:red" %)Return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 466 + 467 +(% style="color:red" %)String after SEARCH command: 2e 30 58 5f 36 41 30 31 00 49 468 + 469 +(% style="color:red" %)Valid payload after DataCUT command: 2e 30 58 5f 36 470 + 471 +[[image:1653269618463-608.png]] 472 + 377 377 === 3.3.4 Compose the uplink payload === 378 378 379 379 ((( 380 380 Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.** 381 - 382 - 383 383 ))) 384 384 385 385 ((( 386 -(% style="color:#037691" %)**Examples: AT+DATAUP=0** 387 - 388 - 480 +(% style="color:#4f81bd" %)**Examples: AT+DATAUP=0** 389 389 ))) 390 390 391 391 ((( ... ... @@ -406,10 +406,8 @@ 406 406 407 407 [[image:1653269759169-150.png||height="513" width="716"]] 408 408 501 +(% style="color:#4f81bd" %)**Examples: AT+DATAUP=1** 409 409 410 -(% style="color:#037691" %)**Examples: AT+DATAUP=1** 411 - 412 - 413 413 Compose the uplink payload with value returns in sequence and send with (% style="color:red" %)**Multiply UPLINKs**. 414 414 415 415 Final Payload is ... ... @@ -416,107 +416,700 @@ 416 416 417 417 (% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA** 418 418 419 -1. PAYVER: Defined by AT+PAYVER 420 -1. PAYLOAD COUNT: Total how many uplinks of this sampling. 421 -1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT) 422 -1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes 509 +1. Battery Info (2 bytes): Battery voltage 510 +1. PAYVER (1 byte): Defined by AT+PAYVER 511 +1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling. 512 +1. PAYLOAD# (1 byte): Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT) 513 +1. DATA: Valid value: max 6 bytes(US915 version here, Notice*!) for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 6 bytes 423 423 424 -[[image: image-20220602155039-4.png]]515 +[[image:1653269916228-732.png||height="433" width="711"]] 425 425 426 426 427 -So totally there will be 3 uplinks for this sampling, each uplink include 8bytes DATA518 +So totally there will be 3 uplinks for this sampling, each uplink includes 6 bytes DATA 428 428 429 -DATA1=RETURN1 Valid Value +thefirsttwof Validvalueof RETURN10= **20 20 0a 33 90 4102 aa**520 +DATA1=RETURN1 Valid Value = (% style="background-color:green; color:white" %)20 20 0a 33 90 41 430 430 431 -DATA2= 3^^rd^^ ~~10^^th^^ byte of Valid value of RETURN10=**05810a202020 202d**522 +DATA2=1^^st^^ ~~ 6^^th^^ byte of Valid value of RETURN10=(% style="background-color:green; color:white" %) 02 aa 05 81 0a 20 432 432 433 -DATA3=th erestof Valid value of RETURN10=**30**524 +DATA3=7^^th^^ ~~ 11^^th^^ bytes of Valid value of RETURN10 = (% style="background-color:green; color:white" %)20 20 20 2d 30 434 434 526 +Below are the uplink payloads: 435 435 436 - (% style="color:red" %)Notice: In firmwarev1.3, the Max bytes has beenchanged according to the max bytes in different Frequency Bands for lowest SF. As below:528 +[[image:1653270130359-810.png]] 437 437 438 - ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink. 439 439 440 - ForAU915/AS923bands,if UplinkDwelltime=0,max11bytes for eachuplink.531 +(% style="color:red" %)**Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below:** 441 441 442 - * S915 band, max 11bytes.533 + ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink ( so 51 -5 = 46 max valid date) 443 443 444 - ~*allotherbands:max51 bytes for each uplink.535 + * For AU915/AS923 bands, if UplinkDwell time=1, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date). 445 445 537 + * For US915 band, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date). 446 446 447 - Belowarethe uplinkpayloads:539 + ~* For all other bands: max 51 bytes for each uplink ( so 51 -5 = 46 max valid date). 448 448 449 -[[image:1654157178836-407.png]] 450 - 451 - 452 452 === 3.3.5 Uplink on demand === 453 453 454 -Except uplink periodically, RS485-L Nis able to uplink on demand. The server send downlink command to RS485-LNand RS485 will uplink data base on the command.543 +Except uplink periodically, RS485-BL is able to uplink on demand. The server sends downlink command to RS485-BL and RS485 will uplink data base on the command. 455 455 456 456 Downlink control command: 457 457 458 - **0x08 command**: Poll an uplink with current command set in RS485-LN.547 +[[0x08 command>>path:#downlink_08]]: Poll an uplink with current command set in RS485-BL. 459 459 460 - **0xA8 command**: Send a command to RS485-LNand uplink the output from sensors.549 +[[0xA8 command>>path:#downlink_A8]]: Send a command to RS485-BL and uplink the output from sensors. 461 461 462 462 463 463 464 -=== 3.3.6 Uplink on Interrupt === 553 +1. 554 +11. 555 +111. Uplink on Interrupt 465 465 466 - RS485-LN supportexternalInterruptuplinksincehardwarev1.2release.557 +Put the interrupt sensor between 3.3v_out and GPIO ext.[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]] 467 467 468 - [[image:1654157342174-798.png]]559 +AT+INTMOD=0 Disable Interrupt 469 469 470 - ConnecttheInterruptpinto RS485-LN INT port and connect the GND pin to V- port.Whenthereisa highvoltage(Max 24v) on INT pin. Device willsend an uplinkpacket.561 +AT+INTMOD=1 Interrupt trigger by rising or falling edge. 471 471 563 +AT+INTMOD=2 Interrupt trigger by falling edge. ( Default Value) 472 472 473 -= =3.4UplinkPayload==565 +AT+INTMOD=3 Interrupt trigger by rising edge. 474 474 475 -(% border="1" style="background-color:#4bacc6; color:white; width:734px" %) 476 -|**Size(bytes)**|(% style="width:120px" %)**2**|(% style="width:116px" %)**1**|(% style="width:386px" %)**Length depends on the return from the commands** 477 -|Value|(% style="width:120px" %)((( 567 + 568 +1. 569 +11. Uplink Payload 570 + 571 +|**Size(bytes)**|**2**|**1**|**Length depends on the return from the commands** 572 +|Value|((( 478 478 Battery(mV) 479 479 480 480 & 481 481 482 482 Interrupt _Flag 483 -)))|( % style="width:116px" %)(((578 +)))|((( 484 484 PAYLOAD_VER 485 485 486 486 487 -)))| (% style="width:386px" %)If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server.582 +)))|If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server. 488 488 489 489 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors. 490 490 491 491 492 - == 3.5 Configure RS485-BL viaATorDownlink==587 +function Decoder(bytes, port) { 493 493 494 - UsercanconfigureRS485-LNvia AT Commands or LoRaWANDownlink Commands589 +~/~/Payload Formats of RS485-BL Deceive 495 495 591 +return { 592 + 593 + ~/~/Battery,units:V 594 + 595 + BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000, 596 + 597 + ~/~/GPIO_EXTI 598 + 599 + EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE", 600 + 601 + ~/~/payload of version 602 + 603 + Pay_ver:bytes[2], 604 + 605 + }; 606 + 607 + } 608 + 609 + 610 + 611 + 612 + 613 + 614 + 615 +TTN V3 uplink screen shot. 616 + 617 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]] 618 + 619 +1. 620 +11. Configure RS485-BL via AT or Downlink 621 + 622 +User can configure RS485-BL via [[AT Commands >>path:#_Using_the_AT]]or LoRaWAN Downlink Commands 623 + 496 496 There are two kinds of Commands: 497 497 498 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports:[[End Device AT Commandsand Downlink Command>>doc:Main.End.WebHome]]626 +* **Common Commands**: They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands 499 499 500 -* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN. User can see these commands below:628 +* **Sensor Related Commands**: These commands are special designed for RS485-BL. User can see these commands below: 501 501 630 +1. 631 +11. 632 +111. Common Commands: 502 502 503 - ===3.5.1CommonCommands ===634 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]] 504 504 505 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 506 506 637 +1. 638 +11. 639 +111. Sensor related commands: 507 507 508 -=== 3.5.2 Sensorrelatedcommands===641 +==== Choose Device Type (RS485 or TTL) ==== 509 509 510 -R esponsefeatureisaddedtotheserver'sdownlink,aspecialpackagewithFPort of200 will beuploadedimmediatelyafterreceiving the data sent by theserver.643 +RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect. 511 511 512 - [[image:image-20220602163333-5.png||height="263" width="1160"]]645 +* AT Command 513 513 514 -T hefirstbyte ofthisackage representswhethertheconfiguration issuccessful,00 represents failure,01 representssuccess. Exceptforthe first byte,theotheris the previousdownlink. (All commandsexceptA8typecommandsareapplicable)647 +**AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins. 515 515 649 +**AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins. 516 516 517 -3.5.3 Sensor related commands 518 518 519 -(% class="wikigeneratedid" %) 520 -==== ==== 652 +* Downlink Payload 521 521 522 -==== ==== 654 +**0A aa** à same as AT+MOD=aa 655 + 656 + 657 + 658 +==== [[RS485 Debug Command>>path:#downlink_A8]] (AT+CFGDEV) ==== 659 + 660 +This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling. 661 + 662 +* AT Command 663 + 664 +AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 665 + 666 +m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command. 667 + 668 + 669 + 670 +* Downlink Payload 671 + 672 +Format: A8 MM NN XX XX XX XX YY 673 + 674 +Where: 675 + 676 +* MM: 1: add CRC-16/MODBUS ; 0: no CRC 677 +* NN: The length of RS485 command 678 +* XX XX XX XX: RS485 command total NN bytes 679 +* YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command 680 + 681 +**Example 1:** 682 + 683 +To connect a Modbus Alarm with below commands. 684 + 685 +* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 686 + 687 +* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 688 + 689 +So if user want to use downlink command to control to RS485 Alarm, he can use: 690 + 691 +**A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm 692 + 693 +**A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm 694 + 695 +A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 696 + 697 + 698 +**Example 2:** 699 + 700 +Check TTL Sensor return: 701 + 702 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]] 703 + 704 + 705 + 706 + 707 +==== Set Payload version ==== 708 + 709 +This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. 710 + 711 +* AT Command: 712 + 713 +AT+PAYVER: Set PAYVER field = 1 714 + 715 + 716 +* Downlink Payload: 717 + 718 +0xAE 01 à Set PAYVER field = 0x01 719 + 720 +0xAE 0F à Set PAYVER field = 0x0F 721 + 722 + 723 +==== Set RS485 Sampling Commands ==== 724 + 725 +AT+COMMANDx, AT+DATACUTx and AT+SEARCHx 726 + 727 +These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#polling_485]]. 728 + 729 + 730 +* AT Command: 731 + 732 +AT+COMMANDx: Configure RS485 read command to sensor. 733 + 734 +AT+DATACUTx: Configure how to handle return from RS485 devices. 735 + 736 +AT+SEARCHx: Configure search command 737 + 738 + 739 +* Downlink Payload: 740 + 741 +0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 742 + 743 +Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 744 + 745 +Format: AF MM NN LL XX XX XX XX YY 746 + 747 +Where: 748 + 749 +* MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 750 +* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 751 +* LL: The length of AT+COMMAND or AT+DATACUT command 752 +* XX XX XX XX: AT+COMMAND or AT+DATACUT command 753 +* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command. 754 + 755 +Example: 756 + 757 +**AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1 758 + 759 +**AF 03 02 06 10 01 05 06 09 0A 00**: Same as AT+DATACUT3=**16**,**1**,**5+6+9+10** 760 + 761 +**AF 03 02 06 0B 02 05 07 08 0A 00**: Same as AT+DATACUT3=**11**,**2**,**5~~7+8~~10** 762 + 763 + 764 +0xAB downlink command can be used for set AT+SEARCHx 765 + 766 +Example: **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So 767 + 768 +* AB aa 01 03 xx xx xx same as AT+SEARCHaa=1,xx xx xx 769 +* AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands 770 + 771 +**AB aa 02 03 xx xx xx 02 yy yy** same as **AT+SEARCHaa=2,xx xx xx+yy yy** 772 + 773 + 774 +==== Fast command to handle MODBUS device ==== 775 + 776 +AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 777 + 778 +This command is valid since v1.3 firmware version 779 + 780 + 781 +AT+MBFUN has only two value: 782 + 783 +* AT+MBFUN=1: Enable Modbus reading. And get response base on the MODBUS return 784 + 785 +AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 786 + 787 +* AT+MBFUN=0: Disable Modbus fast reading. 788 + 789 +Example: 790 + 791 +* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). 792 +* AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 793 +* AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 794 + 795 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]] 796 + 797 + 798 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]] 799 + 800 + 801 +* Downlink Commands: 802 + 803 +A9 aa -à Same as AT+MBFUN=aa 804 + 805 + 806 +==== RS485 command timeout ==== 807 + 808 +Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. 809 + 810 +Default value: 0, range: 0 ~~ 5 seconds 811 + 812 + 813 +* AT Command: 814 + 815 +AT+CMDDLaa=hex(bb cc) 816 + 817 +Example: 818 + 819 +**AT+CMDDL1=1000** to send the open time to 1000ms 820 + 821 + 822 +* Downlink Payload: 823 + 824 +0x AA aa bb cc 825 + 826 +Same as: AT+CMDDLaa=hex(bb cc) 827 + 828 + Example: 829 + 830 + 0xAA 01 03 E8 à Same as **AT+CMDDL1=1000 ms** 831 + 832 + 833 +==== [[Uplink>>path:#downlink_A8]] payload mode ==== 834 + 835 +Define to use one uplink or multiple uplinks for the sampling. 836 + 837 +The use of this command please see: [[Compose Uplink payload>>path:#DataUP]] 838 + 839 +* AT Command: 840 + 841 +AT+DATAUP=0 842 + 843 +AT+DATAUP=1 844 + 845 + 846 +* Downlink Payload: 847 + 848 +0xAD 00 à Same as AT+DATAUP=0 849 + 850 +0xAD 01 à Same as AT+DATAUP=1 851 + 852 + 853 +==== Manually trigger an Uplink ==== 854 + 855 +Ask device to send an uplink immediately. 856 + 857 +* Downlink Payload: 858 + 859 +0x08 FF, RS485-BL will immediately send an uplink. 860 + 861 + 862 +==== Clear RS485 Command ==== 863 + 864 +The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 865 + 866 + 867 +* AT Command: 868 + 869 +**AT+CMDEAR=mm,nn** mm: start position of erase ,nn: stop position of erase 870 + 871 +Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 872 + 873 +Example screen shot after clear all RS485 commands. 874 + 875 + 876 + 877 +The uplink screen shot is: 878 + 879 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]] 880 + 881 + 882 +* Downlink Payload: 883 + 884 +0x09 aa bb same as AT+CMDEAR=aa,bb 885 + 886 + 887 +==== Set Serial Communication Parameters ==== 888 + 889 +Set the Rs485 serial communication parameters: 890 + 891 +* AT Command: 892 + 893 +Set Baud Rate: 894 + 895 +AT+BAUDR=9600 ~/~/ Options: (1200,2400,4800,14400,19200,115200) 896 + 897 + 898 +Set UART parity 899 + 900 +AT+PARITY=0 ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 901 + 902 + 903 +Set STOPBIT 904 + 905 +AT+STOPBIT=0 ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 906 + 907 + 908 +* Downlink Payload: 909 + 910 +A7 01 aa bb: Same AT+BAUDR=hex(aa bb)*100 911 + 912 +Example: 913 + 914 +* A7 01 00 60 same as AT+BAUDR=9600 915 +* A7 01 04 80 same as AT+BAUDR=115200 916 + 917 +A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 918 + 919 +A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 920 + 921 + 922 +==== Control output power duration ==== 923 + 924 +User can set the output power duration before each sampling. 925 + 926 +* AT Command: 927 + 928 +Example: 929 + 930 +AT+3V3T=1000 ~/~/ 3V3 output power will open 1s before each sampling. 931 + 932 +AT+5VT=1000 ~/~/ +5V output power will open 1s before each sampling. 933 + 934 + 935 +* LoRaWAN Downlink Command: 936 + 937 +07 01 aa bb Same as AT+5VT=(aa bb) 938 + 939 +07 02 aa bb Same as AT+3V3T=(aa bb) 940 + 941 + 942 + 943 + 944 +1. 945 +11. Buttons 946 + 947 +|**Button**|**Feature** 948 +|**RST**|Reboot RS485-BL 949 + 950 +1. 951 +11. +3V3 Output 952 + 953 +RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. 954 + 955 +The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 956 + 957 + 958 +The +3V3 output time can be controlled by AT Command. 959 + 960 +**AT+3V3T=1000** 961 + 962 +Means set +3v3 valid time to have 1000ms. So, the real +3v3 output will actually have 1000ms + sampling time for other sensors. 963 + 964 + 965 +By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 966 + 967 + 968 +1. 969 +11. +5V Output 970 + 971 +RS485-BL has a Controllable +5V output, user can use this output to power external sensor. 972 + 973 +The +5V output will be valid for every sampling. RS485-BL will enable +5V output before all sampling and disable the +5v after all sampling. 974 + 975 + 976 +The 5V output time can be controlled by AT Command. 977 + 978 +**AT+5VT=1000** 979 + 980 +Means set 5V valid time to have 1000ms. So, the real 5V output will actually have 1000ms + sampling time for other sensors. 981 + 982 + 983 +By default, the AT+5VT=0. If the external sensor which require 5v and require more time to get stable state, user can use this command to increase the power ON duration for this sensor. 984 + 985 + 986 + 987 + 988 +1. 989 +11. LEDs 990 + 991 +|**LEDs**|**Feature** 992 +|**LED1**|Blink when device transmit a packet. 993 + 994 +1. 995 +11. Switch Jumper 996 + 997 +|**Switch Jumper**|**Feature** 998 +|**SW1**|((( 999 +ISP position: Upgrade firmware via UART 1000 + 1001 +Flash position: Configure device, check running status. 1002 +))) 1003 +|**SW2**|((( 1004 +5V position: set to compatible with 5v I/O. 1005 + 1006 +3.3v position: set to compatible with 3.3v I/O., 1007 +))) 1008 + 1009 ++3.3V: is always ON 1010 + 1011 ++5V: Only open before every sampling. The time is by default, it is AT+5VT=0. Max open time. 5000 ms. 1012 + 1013 +1. Case Study 1014 + 1015 +User can check this URL for some case studies. 1016 + 1017 +[[http:~~/~~/wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS>>url:http://wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS]] 1018 + 1019 + 1020 + 1021 + 1022 +1. Use AT Command 1023 +11. Access AT Command 1024 + 1025 +RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1026 + 1027 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]] 1028 + 1029 + 1030 +In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1031 + 1032 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]] 1033 + 1034 + 1035 + 1036 +More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]] 1037 + 1038 + 1039 + 1040 +1. 1041 +11. Common AT Command Sequence 1042 +111. Multi-channel ABP mode (Use with SX1301/LG308) 1043 + 1044 +If device has not joined network yet: 1045 + 1046 +AT+FDR 1047 + 1048 +AT+NJM=0 1049 + 1050 +ATZ 1051 + 1052 + 1053 +If device already joined network: 1054 + 1055 +AT+NJM=0 1056 + 1057 +ATZ 1058 + 1059 +1. 1060 +11. 1061 +111. Single-channel ABP mode (Use with LG01/LG02) 1062 + 1063 +AT+FDR Reset Parameters to Factory Default, Keys Reserve 1064 + 1065 +AT+NJM=0 Set to ABP mode 1066 + 1067 +AT+ADR=0 Set the Adaptive Data Rate Off 1068 + 1069 +AT+DR=5 Set Data Rate 1070 + 1071 +AT+TDC=60000 Set transmit interval to 60 seconds 1072 + 1073 +AT+CHS=868400000 Set transmit frequency to 868.4Mhz 1074 + 1075 +AT+RX2FQ=868400000 Set RX2Frequency to 868.4Mhz (according to the result from server) 1076 + 1077 +AT+RX2DR=5 Set RX2DR to match the downlink DR from server. see below 1078 + 1079 +AT+DADDR=26 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1080 + 1081 +ATZ Reset MCU 1082 + 1083 +**Note:** 1084 + 1085 +1. Make sure the device is set to ABP mode in the IoT Server. 1086 +1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1087 +1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1088 +1. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1089 + 1090 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image029.png]] 1091 + 1092 + 1093 +1. FAQ 1094 +11. How to upgrade the image? 1095 + 1096 +The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to: 1097 + 1098 +* Support new features 1099 +* For bug fix 1100 +* Change LoRaWAN bands. 1101 + 1102 +Below shows the hardware connection for how to upload an image to RS485-BL: 1103 + 1104 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image030.png]] 1105 + 1106 +**Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1107 + 1108 +**Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1109 + 1110 +**Step3: **Open flashloader; choose the correct COM port to update. 1111 + 1112 + 1113 +|((( 1114 +HOLD PRO then press the RST button, SYS will be ON, then click next 1115 +))) 1116 + 1117 +|((( 1118 +Board detected 1119 +))) 1120 + 1121 +|((( 1122 + 1123 +))) 1124 + 1125 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image031.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image032.png]] 1126 + 1127 + 1128 + 1129 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image033.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image034.png]] 1130 + 1131 + 1132 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1133 + 1134 + 1135 +1. 1136 +11. How to change the LoRa Frequency Bands/Region? 1137 + 1138 +User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. 1139 + 1140 + 1141 + 1142 +1. 1143 +11. How many RS485-Slave can RS485-BL connects? 1144 + 1145 +The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. 1146 + 1147 + 1148 + 1149 + 1150 +1. Trouble Shooting 1151 +11. Downlink doesn’t work, how to solve it? 1152 + 1153 +Please see this link for debug: 1154 + 1155 +[[http:~~/~~/wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug>>url:http://wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug]] 1156 + 1157 + 1158 + 1159 +1. 1160 +11. Why I can’t join TTN V3 in US915 /AU915 bands? 1161 + 1162 +It might about the channels mapping. Please see for detail. 1163 + 1164 +[[http:~~/~~/wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band>>url:http://wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band]] 1165 + 1166 + 1167 + 1168 +1. Order Info 1169 + 1170 +**Part Number: RS485-BL-XXX** 1171 + 1172 +**XXX:** 1173 + 1174 +* **EU433**: frequency bands EU433 1175 +* **EU868**: frequency bands EU868 1176 +* **KR920**: frequency bands KR920 1177 +* **CN470**: frequency bands CN470 1178 +* **AS923**: frequency bands AS923 1179 +* **AU915**: frequency bands AU915 1180 +* **US915**: frequency bands US915 1181 +* **IN865**: frequency bands IN865 1182 +* **RU864**: frequency bands RU864 1183 +* **KZ865: **frequency bands KZ865 1184 + 1185 +1. Packing Info 1186 + 1187 +**Package Includes**: 1188 + 1189 +* RS485-BL x 1 1190 +* Stick Antenna for LoRa RF part x 1 1191 +* Program cable x 1 1192 + 1193 +**Dimension and weight**: 1194 + 1195 +* Device Size: 13.5 x 7 x 3 cm 1196 +* Device Weight: 105g 1197 +* Package Size / pcs : 14.5 x 8 x 5 cm 1198 +* Weight / pcs : 170g 1199 + 1200 +1. Support 1201 + 1202 +* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1203 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to 1204 + 1205 +[[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
- 1654157178836-407.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -179.9 KB - Content
- 1654157342174-798.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -31.9 KB - Content
- 1654158783574-851.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -40.6 KB - Content
- image-20220602153621-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.4 KB - Content
- image-20220602153621-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.2 KB - Content
- image-20220602153621-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.3 KB - Content
- image-20220602155039-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.6 KB - Content
- image-20220602163333-5.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -48.2 KB - Content