... ... @@ -76,6 +76,8 @@
76 76  * Automatic RF Sense and CAD with ultra-fast AFC.
77 77  * Packet engine up to 256 bytes with CRC.
78 78  
79 +
80 +
79 79  == 1.3 Features ==
80 80  
81 81  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -87,6 +87,8 @@
87 87  * Support Modbus protocol
88 88  * Support Interrupt uplink (Since hardware version v1.2)
89 89  
92 +
93 +
90 90  == 1.4 Applications ==
91 91  
92 92  * Smart Buildings & Home Automation
... ... @@ -96,6 +96,8 @@
96 96  * Smart Cities
97 97  * Smart Factory
98 98  
103 +
104 +
99 99  == 1.5 Firmware Change log ==
100 100  
101 101  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -216,8 +216,6 @@
216 216  
217 217  (((
218 218  (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1
219 -
220 -
221 221  )))
222 222  )))
223 223  
... ... @@ -225,19 +225,19 @@
225 225  
226 226  To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
227 227  
228 -(% border="1" style="background-color:#ffffcc; color:green; width:782px" %)
229 -|(% style="width:128px" %)(((
232 +(% border="1" style="background-color:#ffffcc; color:green; width:795px" %)
233 +|(((
230 230  **AT Commands**
231 -)))|(% style="width:305px" %)(((
235 +)))|(% style="width:285px" %)(((
232 232  **Description**
233 -)))|(% style="width:346px" %)(((
237 +)))|(% style="width:347px" %)(((
234 234  **Example**
235 235  )))
236 -|(% style="width:128px" %)(((
240 +|(((
237 237  AT+BAUDR
238 -)))|(% style="width:305px" %)(((
242 +)))|(% style="width:285px" %)(((
239 239  Set the baud rate (for RS485 connection). Default Value is: 9600.
240 -)))|(% style="width:346px" %)(((
244 +)))|(% style="width:347px" %)(((
241 241  (((
242 242  AT+BAUDR=9600
243 243  )))
... ... @@ -246,11 +246,11 @@
246 246  Options: (1200,2400,4800,14400,19200,115200)
247 247  )))
248 248  )))
249 -|(% style="width:128px" %)(((
253 +|(((
250 250  AT+PARITY
251 -)))|(% style="width:305px" %)(((
255 +)))|(% style="width:285px" %)(((
252 252  Set UART parity (for RS485 connection)
253 -)))|(% style="width:346px" %)(((
257 +)))|(% style="width:347px" %)(((
254 254  (((
255 255  AT+PARITY=0
256 256  )))
... ... @@ -259,9 +259,9 @@
259 259  Option: 0: no parity, 1: odd parity, 2: even parity
260 260  )))
261 261  )))
262 -|(% style="width:128px" %)(((
266 +|(((
263 263  AT+STOPBIT
264 -)))|(% style="width:305px" %)(((
268 +)))|(% style="width:285px" %)(((
265 265  (((
266 266  Set serial stopbit (for RS485 connection)
267 267  )))
... ... @@ -269,7 +269,7 @@
269 269  (((
270 270  
271 271  )))
272 -)))|(% style="width:346px" %)(((
276 +)))|(% style="width:347px" %)(((
273 273  (((
274 274  AT+STOPBIT=0 for 1bit
275 275  )))
... ... @@ -304,34 +304,77 @@
304 304  === 3.3.3 Configure read commands for each sampling ===
305 305  
306 306  (((
307 -During each sampling, we need confirm what commands we need to send to the RS485 sensors to read data. After the RS485 sensors send back the value, it normally include some bytes and we only need a few from them for a shorten payload.
311 +RS485-BL is a battery powered device; it will sleep most of time. And wake up on each period and read RS485 / TTL sensor data and uplink.
312 +)))
308 308  
314 +(((
315 +During each sampling, we need to confirm what commands we need to send to the sensors to read data. After the RS485/TTL sensors send back the value, it normally includes some bytes and we only need a few from them for a shorten payload.
316 +)))
317 +
318 +(((
309 309  To save the LoRaWAN network bandwidth, we might need to read data from different sensors and combine their valid value into a short payload.
320 +)))
310 310  
322 +(((
311 311  This section describes how to achieve above goals.
324 +)))
312 312  
313 -During each sampling, the RS485-LN can support 15 commands to read sensors. And combine the return to one or several uplink payloads.
326 +(((
327 +During each sampling, the RS485-BL can support 15 commands to read sensors. And combine the return to one or several uplink payloads.
328 +)))
314 314  
330 +(((
331 +**Command from RS485-BL to Sensor:**
332 +)))
315 315  
316 -**Each RS485 commands include two parts:**
334 +(((
335 +RS485-BL can send out pre-set max 15 strings via **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF** . All commands are of same grammar.
336 +)))
317 317  
318 -~1. What commands RS485-LN will send to the RS485 sensors. There are total 15 commands from **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF**. All commands are of same grammar.
338 +(((
339 +**Handle return from sensors to RS485-BL**:
340 +)))
319 319  
320 -2. How to get wanted value the from RS485 sensors returns from by 1). There are total 15 AT Commands to handle the return, commands are **AT+DATACUT1**,**AT+DATACUT2**,…, **AT+DATACUTF** corresponding to the commands from 1). All commands are of same grammar.
342 +(((
343 +After RS485-BL send out a string to sensor, RS485-BL will wait for the return from RS485 or TTL sensor. And user can specify how to handle the return, by **AT+DATACUT or AT+SEARCH commands**
344 +)))
321 321  
322 -3. Some RS485 device might has longer delay on reply, so user can use AT+CMDDL to set the timeout for getting reply after the RS485 command is sent. For example **AT+CMDDL1=1000** to send the open time to 1000ms
346 +* (((
347 +**AT+DATACUT**
348 +)))
323 323  
350 +(((
351 +When the return value from sensor have fix length and we know which position the valid value we should get, we can use AT+DATACUT command.
352 +)))
324 324  
354 +* (((
355 +**AT+SEARCH**
356 +)))
357 +
358 +(((
359 +When the return value from sensor is dynamic length and we are not sure which bytes the valid data is, instead, we know what value the valid value following. We can use AT+SEARCH to search the valid value in the return string.
360 +)))
361 +
362 +(((
363 +**Define wait timeout:**
364 +)))
365 +
366 +(((
367 +Some RS485 device might has longer delay on reply, so user can use AT+CMDDL to set the timeout for getting reply after the RS485 command is sent. For example, AT+CMDDL1=1000 to send the open time to 1000ms
368 +)))
369 +
370 +(((
325 325  After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**.
372 +)))
326 326  
374 +**Examples:**
327 327  
328 328  Below are examples for the how above AT Commands works.
329 329  
378 +**AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is:
330 330  
331 -**AT+COMMANDx : **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is:
332 -
333 -(% border="1" style="background-color:#4bacc6; color:white; width:499px" %)
334 -|(% style="width:496px" %)(((
380 +(% border="1" class="table-bordered" %)
381 +|(((
335 335  **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
336 336  
337 337  **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent**
... ... @@ -339,15 +339,49 @@
339 339  **m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command**
340 340  )))
341 341  
389 +(((
342 342  For example, if we have a RS485 sensor. The command to get sensor value is: 01 03 0B B8 00 02 46 0A. Where 01 03 0B B8 00 02 is the Modbus command to read the register 0B B8 where stored the sensor value. The 46 0A is the CRC-16/MODBUS which calculate manually.
391 +)))
343 343  
344 -In the RS485-LN, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same.
393 +(((
394 +In the RS485-BL, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same.
395 +)))
345 345  
397 +(((
398 +**AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx.
399 +)))
346 346  
401 +(% border="1" class="table-bordered" %)
402 +|(((
403 +**AT+SEARCHx=aa,xx xx xx xx xx**
404 +
405 +* **aa: 1: prefix match mode; 2: prefix and suffix match mode**
406 +* **xx xx xx xx xx: match string. Max 5 bytes for prefix and 5 bytes for suffix**
407 +
408 +
409 +)))
410 +
411 +**Examples:**
412 +
413 +~1. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
414 +
415 +If we set AT+SEARCH1=1,1E 56 34.      (max 5 bytes for prefix)
416 +
417 +The valid data will be all bytes after 1E 56 34 , so it is (% style="background-color:yellow" %)** 2e 30 58 5f 36 41 30 31 00 49**
418 +
419 +[[image:1653269403619-508.png]]
420 +
421 +2. For a return string from AT+COMMAND1:  16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
422 +
423 +If we set AT+SEARCH1=2, 1E 56 34+31 00 49
424 +
425 +Device will search the bytes between 1E 56 34 and 31 00 49. So it is (% style="background-color:yellow" %)** 2e 30 58 5f 36 41 30**
426 +
427 +[[image:1653269438444-278.png]]
428 +
347 347  **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
348 348  
349 -(% border="1" style="background-color:#4bacc6; color:white; width:725px" %)
350 -|(% style="width:722px" %)(((
431 +|(((
351 351  **AT+DATACUTx=a,b,c**
352 352  
353 353  * **a: length for the return of AT+COMMAND**
... ... @@ -355,37 +355,48 @@
355 355  * **c: define the position for valid value.  **
356 356  )))
357 357  
358 -**Examples:**
439 +Examples:
359 359  
360 360  * Grab bytes:
361 361  
362 -[[image:image-20220602153621-1.png]]
443 +[[image:1653269551753-223.png||height="311" width="717"]]
363 363  
364 -
365 365  * Grab a section.
366 366  
367 -[[image:image-20220602153621-2.png]]
447 +[[image:1653269568276-930.png||height="325" width="718"]]
368 368  
369 -
370 370  * Grab different sections.
371 371  
372 -[[image:image-20220602153621-3.png]]
451 +[[image:1653269593172-426.png||height="303" width="725"]]
373 373  
374 -
375 -)))
453 +(% style="color:red" %)**Note:**
376 376  
455 +AT+SEARCHx and AT+DATACUTx can be used together, if both commands are set, RS485-BL will first process AT+SEARCHx on the return string and get a temporary string, and then process AT+DATACUTx on this temporary string to get the final payload. In this case, AT+DATACUTx need to set to format AT+DATACUTx=0,xx,xx where the return bytes set to 0.
456 +
457 +Example:
458 +
459 +(% style="color:red" %)AT+COMMAND1=11 01 1E D0,0
460 +
461 +(% style="color:red" %)AT+SEARCH1=1,1E 56 34
462 +
463 +(% style="color:red" %)AT+DATACUT1=0,2,1~~5
464 +
465 +(% style="color:red" %)Return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
466 +
467 +(% style="color:red" %)String after SEARCH command: 2e 30 58 5f 36 41 30 31 00 49
468 +
469 +(% style="color:red" %)Valid payload after DataCUT command: 2e 30 58 5f 36
470 +
471 +[[image:1653269618463-608.png]]
472 +
377 377  === 3.3.4 Compose the uplink payload ===
378 378  
379 379  (((
380 380  Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.**
381 -
382 -
383 383  )))
384 384  
385 385  (((
386 -(% style="color:#037691" %)**Examples: AT+DATAUP=0**
387 -
388 -
480 +(% style="color:#4f81bd" %)**Examples: AT+DATAUP=0**
389 389  )))
390 390  
391 391  (((
... ... @@ -406,10 +406,8 @@
406 406  
407 407  [[image:1653269759169-150.png||height="513" width="716"]]
408 408  
501 +(% style="color:#4f81bd" %)**Examples: AT+DATAUP=1**
409 409  
410 -(% style="color:#037691" %)**Examples: AT+DATAUP=1**
411 -
412 -
413 413  Compose the uplink payload with value returns in sequence and send with (% style="color:red" %)**Multiply UPLINKs**.
414 414  
415 415  Final Payload is
... ... @@ -416,107 +416,700 @@
416 416  
417 417  (% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**
418 418  
419 -1. PAYVER: Defined by AT+PAYVER
420 -1. PAYLOAD COUNT: Total how many uplinks of this sampling.
421 -1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
422 -1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes
509 +1. Battery Info (2 bytes): Battery voltage
510 +1. PAYVER (1 byte): Defined by AT+PAYVER
511 +1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling.
512 +1. PAYLOAD# (1 byte): Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
513 +1. DATA: Valid value: max 6 bytes(US915 version here, Notice*!) for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 6 bytes
423 423  
424 -[[image:image-20220602155039-4.png]]
515 +[[image:1653269916228-732.png||height="433" width="711"]]
425 425  
426 426  
427 -So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA
518 +So totally there will be 3 uplinks for this sampling, each uplink includes 6 bytes DATA
428 428  
429 -DATA1=RETURN1 Valid Value + the first two of Valid value of RETURN10= **20 20 0a 33 90 41 02 aa**
520 +DATA1=RETURN1 Valid Value = (% style="background-color:green; color:white" %)20 20 0a 33 90 41
430 430  
431 -DATA2=3^^rd^^ ~~ 10^^th^^ byte of Valid value of RETURN10= **05 81 0a 20 20 20 20 2d**
522 +DATA2=1^^st^^ ~~ 6^^th^^ byte of Valid value of RETURN10=(% style="background-color:green; color:white" %) 02 aa 05 81 0a 20
432 432  
433 -DATA3=the rest of Valid value of RETURN10= **30**
524 +DATA3=7^^th^^ ~~ 11^^th^^ bytes of Valid value of RETURN10 = (% style="background-color:green; color:white" %)20 20 20 2d 30
434 434  
526 +Below are the uplink payloads:
435 435  
436 -(% style="color:red" %)Notice: In firmware v1.3, the Max bytes has been changed according to the max bytes in different Frequency Bands for lowest SF. As below:
528 +[[image:1653270130359-810.png]]
437 437  
438 - ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink.
439 439  
440 - * For AU915/AS923 bands, if UplinkDwell time=0, max 11 bytes for each uplink.
531 +(% style="color:red" %)**Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below:**
441 441  
442 - * For US915 band, max 11 bytes for each uplink.
533 + ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink ( so 51 -5 = 46 max valid date)
443 443  
444 - ~* For all other bands: max 51 bytes for each uplink.
535 + * For AU915/AS923 bands, if UplinkDwell time=1, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date).
445 445  
537 + * For US915 band, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date).
446 446  
447 -Below are the uplink payloads:
539 + ~* For all other bands: max 51 bytes for each uplink  ( so 51 -5 = 46 max valid date).
448 448  
449 -[[image:1654157178836-407.png]]
450 -
451 -
452 452  === 3.3.5 Uplink on demand ===
453 453  
454 -Except uplink periodically, RS485-LN is able to uplink on demand. The server send downlink command to RS485-LN and RS485 will uplink data base on the command.
543 +Except uplink periodically, RS485-BL is able to uplink on demand. The server sends downlink command to RS485-BL and RS485 will uplink data base on the command.
455 455  
456 456  Downlink control command:
457 457  
458 -**0x08 command**: Poll an uplink with current command set in RS485-LN.
547 +[[0x08 command>>path:#downlink_08]]: Poll an uplink with current command set in RS485-BL.
459 459  
460 -**0xA8 command**: Send a command to RS485-LN and uplink the output from sensors.
549 +[[0xA8 command>>path:#downlink_A8]]: Send a command to RS485-BL and uplink the output from sensors.
461 461  
462 462  
463 463  
464 -=== 3.3.6 Uplink on Interrupt ===
553 +1.
554 +11.
555 +111. Uplink on Interrupt
465 465  
466 -RS485-LN support external Interrupt uplink since hardware v1.2 release.
557 +Put the interrupt sensor between 3.3v_out and GPIO ext.[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]
467 467  
468 -[[image:1654157342174-798.png]]
559 +AT+INTMOD=0  Disable Interrupt
469 469  
470 -Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet.
561 +AT+INTMOD=1  Interrupt trigger by rising or falling edge.
471 471  
563 +AT+INTMOD=2  Interrupt trigger by falling edge. ( Default Value)
472 472  
473 -== 3.4 Uplink Payload ==
565 +AT+INTMOD=3  Interrupt trigger by rising edge.
474 474  
475 -(% border="1" style="background-color:#4bacc6; color:white; width:734px" %)
476 -|**Size(bytes)**|(% style="width:120px" %)**2**|(% style="width:116px" %)**1**|(% style="width:386px" %)**Length depends on the return from the commands**
477 -|Value|(% style="width:120px" %)(((
567 +
568 +1.
569 +11. Uplink Payload
570 +
571 +|**Size(bytes)**|**2**|**1**|**Length depends on the return from the commands**
572 +|Value|(((
478 478  Battery(mV)
479 479  
480 480  &
481 481  
482 482  Interrupt _Flag
483 -)))|(% style="width:116px" %)(((
578 +)))|(((
484 484  PAYLOAD_VER
485 485  
486 486  
487 -)))|(% style="width:386px" %)If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server.
582 +)))|If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server.
488 488  
489 489  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
490 490  
491 491  
492 -== 3.5 Configure RS485-BL via AT or Downlink ==
587 +function Decoder(bytes, port) {
493 493  
494 -User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands
589 +~/~/Payload Formats of RS485-BL Deceive
495 495  
591 +return {
592 +
593 + ~/~/Battery,units:V
594 +
595 + BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000,
596 +
597 + ~/~/GPIO_EXTI 
598 +
599 + EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE",
600 +
601 + ~/~/payload of version
602 +
603 + Pay_ver:bytes[2],
604 +
605 + };
606 +
607 + }
608 +
609 +
610 +
611 +
612 +
613 +
614 +
615 +TTN V3 uplink screen shot.
616 +
617 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
618 +
619 +1.
620 +11. Configure RS485-BL via AT or Downlink
621 +
622 +User can configure RS485-BL via [[AT Commands >>path:#_​Using_the_AT]]or LoRaWAN Downlink Commands
623 +
496 496  There are two kinds of Commands:
497 497  
498 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
626 +* **Common Commands**: They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands
499 499  
500 -* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
628 +* **Sensor Related Commands**: These commands are special designed for RS485-BL.  User can see these commands below:
501 501  
630 +1.
631 +11.
632 +111. Common Commands:
502 502  
503 -=== 3.5.1 Common Commands ===
634 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]]
504 504  
505 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
506 506  
637 +1.
638 +11.
639 +111. Sensor related commands:
507 507  
508 -=== 3.5.2 Sensor related commands ===
641 +==== Choose Device Type (RS485 or TTL) ====
509 509  
510 -Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server.
643 +RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect.
511 511  
512 -[[image:image-20220602163333-5.png||height="263" width="1160"]]
645 +* AT Command
513 513  
514 -The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable)
647 +**AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins.
515 515  
649 +**AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins.
516 516  
517 -3.5.3 Sensor related commands
518 518  
519 -(% class="wikigeneratedid" %)
520 -==== ====
652 +* Downlink Payload
521 521  
522 -==== ====
654 +**0A aa**     à same as AT+MOD=aa
655 +
656 +
657 +
658 +==== [[RS485 Debug Command>>path:#downlink_A8]] (AT+CFGDEV) ====
659 +
660 +This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling.
661 +
662 +* AT Command
663 +
664 +AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
665 +
666 +m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command.
667 +
668 +
669 +
670 +* Downlink Payload
671 +
672 +Format: A8 MM NN XX XX XX XX YY
673 +
674 +Where:
675 +
676 +* MM: 1: add CRC-16/MODBUS ; 0: no CRC
677 +* NN: The length of RS485 command
678 +* XX XX XX XX: RS485 command total NN bytes
679 +* YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command
680 +
681 +**Example 1:**
682 +
683 +To connect a Modbus Alarm with below commands.
684 +
685 +* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
686 +
687 +* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
688 +
689 +So if user want to use downlink command to control to RS485 Alarm, he can use:
690 +
691 +**A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm
692 +
693 +**A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm
694 +
695 +A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output.
696 +
697 +
698 +**Example 2:**
699 +
700 +Check TTL Sensor return:
701 +
702 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]
703 +
704 +
705 +
706 +
707 +==== Set Payload version ====
708 +
709 +This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
710 +
711 +* AT Command:
712 +
713 +AT+PAYVER: Set PAYVER field = 1
714 +
715 +
716 +* Downlink Payload:
717 +
718 +0xAE 01   à Set PAYVER field =  0x01
719 +
720 +0xAE 0F   à Set PAYVER field =  0x0F
721 +
722 +
723 +==== Set RS485 Sampling Commands ====
724 +
725 +AT+COMMANDx, AT+DATACUTx and AT+SEARCHx
726 +
727 +These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#polling_485]].
728 +
729 +
730 +* AT Command:
731 +
732 +AT+COMMANDx: Configure RS485 read command to sensor.
733 +
734 +AT+DATACUTx: Configure how to handle return from RS485 devices.
735 +
736 +AT+SEARCHx: Configure search command
737 +
738 +
739 +* Downlink Payload:
740 +
741 +0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
742 +
743 +Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
744 +
745 +Format: AF MM NN LL XX XX XX XX YY
746 +
747 +Where:
748 +
749 +* MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
750 +* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
751 +* LL: The length of AT+COMMAND or AT+DATACUT command
752 +* XX XX XX XX: AT+COMMAND or AT+DATACUT command
753 +* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command.
754 +
755 +Example:
756 +
757 +**AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1
758 +
759 +**AF 03 02 06 10 01 05 06 09 0A 00**: Same as AT+DATACUT3=**16**,**1**,**5+6+9+10**
760 +
761 +**AF 03 02 06 0B 02 05 07 08 0A 00**: Same as AT+DATACUT3=**11**,**2**,**5~~7+8~~10**
762 +
763 +
764 +0xAB downlink command can be used for set AT+SEARCHx
765 +
766 +Example: **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So
767 +
768 +* AB aa 01 03 xx xx xx  same as AT+SEARCHaa=1,xx xx xx
769 +* AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands
770 +
771 +**AB aa 02 03 xx xx xx 02 yy yy**  same as **AT+SEARCHaa=2,xx xx xx+yy yy**
772 +
773 +
774 +==== Fast command to handle MODBUS device ====
775 +
776 +AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
777 +
778 +This command is valid since v1.3 firmware version
779 +
780 +
781 +AT+MBFUN has only two value:
782 +
783 +* AT+MBFUN=1: Enable Modbus reading. And get response base on the MODBUS return
784 +
785 +AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore.
786 +
787 +* AT+MBFUN=0: Disable Modbus fast reading.
788 +
789 +Example:
790 +
791 +* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0).
792 +* AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
793 +* AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
794 +
795 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]
796 +
797 +
798 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]
799 +
800 +
801 +* Downlink Commands:
802 +
803 +A9 aa -à Same as AT+MBFUN=aa
804 +
805 +
806 +==== RS485 command timeout ====
807 +
808 +Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action.
809 +
810 +Default value: 0, range:  0 ~~ 5 seconds
811 +
812 +
813 +* AT Command:
814 +
815 +AT+CMDDLaa=hex(bb cc)
816 +
817 +Example:
818 +
819 +**AT+CMDDL1=1000** to send the open time to 1000ms
820 +
821 +
822 +* Downlink Payload:
823 +
824 +0x AA aa bb cc
825 +
826 +Same as: AT+CMDDLaa=hex(bb cc)
827 +
828 + Example:
829 +
830 + 0xAA 01 03 E8  à Same as **AT+CMDDL1=1000 ms**
831 +
832 +
833 +==== [[Uplink>>path:#downlink_A8]] payload mode ====
834 +
835 +Define to use one uplink or multiple uplinks for the sampling.
836 +
837 +The use of this command please see: [[Compose Uplink payload>>path:#DataUP]]
838 +
839 +* AT Command:
840 +
841 +AT+DATAUP=0
842 +
843 +AT+DATAUP=1
844 +
845 +
846 +* Downlink Payload:
847 +
848 +0xAD 00   à Same as AT+DATAUP=0
849 +
850 +0xAD 01   à Same as AT+DATAUP=1
851 +
852 +
853 +==== Manually trigger an Uplink ====
854 +
855 +Ask device to send an uplink immediately.
856 +
857 +* Downlink Payload:
858 +
859 +0x08 FF, RS485-BL will immediately send an uplink.
860 +
861 +
862 +==== Clear RS485 Command ====
863 +
864 +The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
865 +
866 +
867 +* AT Command:
868 +
869 +**AT+CMDEAR=mm,nn**   mm: start position of erase ,nn: stop position of erase
870 +
871 +Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
872 +
873 +Example screen shot after clear all RS485 commands. 
874 +
875 +
876 +
877 +The uplink screen shot is:
878 +
879 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
880 +
881 +
882 +* Downlink Payload:
883 +
884 +0x09 aa bb same as AT+CMDEAR=aa,bb
885 +
886 +
887 +==== Set Serial Communication Parameters ====
888 +
889 +Set the Rs485 serial communication parameters:
890 +
891 +* AT Command:
892 +
893 +Set Baud Rate:
894 +
895 +AT+BAUDR=9600    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
896 +
897 +
898 +Set UART parity
899 +
900 +AT+PARITY=0    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
901 +
902 +
903 +Set STOPBIT
904 +
905 +AT+STOPBIT=0    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
906 +
907 +
908 +* Downlink Payload:
909 +
910 +A7 01 aa bb: Same  AT+BAUDR=hex(aa bb)*100
911 +
912 +Example:
913 +
914 +* A7 01 00 60   same as AT+BAUDR=9600
915 +* A7 01 04 80  same as AT+BAUDR=115200
916 +
917 +A7 02 aa: Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
918 +
919 +A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
920 +
921 +
922 +==== Control output power duration ====
923 +
924 +User can set the output power duration before each sampling.
925 +
926 +* AT Command:
927 +
928 +Example:
929 +
930 +AT+3V3T=1000 ~/~/ 3V3 output power will open 1s before each sampling.
931 +
932 +AT+5VT=1000 ~/~/ +5V output power will open 1s before each sampling.
933 +
934 +
935 +* LoRaWAN Downlink Command:
936 +
937 +07 01 aa bb  Same as AT+5VT=(aa bb)
938 +
939 +07 02 aa bb  Same as AT+3V3T=(aa bb)
940 +
941 +
942 +
943 +
944 +1.
945 +11. Buttons
946 +
947 +|**Button**|**Feature**
948 +|**RST**|Reboot RS485-BL
949 +
950 +1.
951 +11. +3V3 Output
952 +
953 +RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
954 +
955 +The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 
956 +
957 +
958 +The +3V3 output time can be controlled by AT Command.
959 +
960 +**AT+3V3T=1000**
961 +
962 +Means set +3v3 valid time to have 1000ms. So, the real +3v3 output will actually have 1000ms + sampling time for other sensors.
963 +
964 +
965 +By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
966 +
967 +
968 +1.
969 +11. +5V Output
970 +
971 +RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
972 +
973 +The +5V output will be valid for every sampling. RS485-BL will enable +5V output before all sampling and disable the +5v after all sampling. 
974 +
975 +
976 +The 5V output time can be controlled by AT Command.
977 +
978 +**AT+5VT=1000**
979 +
980 +Means set 5V valid time to have 1000ms. So, the real 5V output will actually have 1000ms + sampling time for other sensors.
981 +
982 +
983 +By default, the AT+5VT=0. If the external sensor which require 5v and require more time to get stable state, user can use this command to increase the power ON duration for this sensor.
984 +
985 +
986 +
987 +
988 +1.
989 +11. LEDs
990 +
991 +|**LEDs**|**Feature**
992 +|**LED1**|Blink when device transmit a packet.
993 +
994 +1.
995 +11. Switch Jumper
996 +
997 +|**Switch Jumper**|**Feature**
998 +|**SW1**|(((
999 +ISP position: Upgrade firmware via UART
1000 +
1001 +Flash position: Configure device, check running status.
1002 +)))
1003 +|**SW2**|(((
1004 +5V position: set to compatible with 5v I/O.
1005 +
1006 +3.3v position: set to compatible with 3.3v I/O.,
1007 +)))
1008 +
1009 ++3.3V: is always ON
1010 +
1011 ++5V: Only open before every sampling. The time is by default, it is AT+5VT=0.  Max open time. 5000 ms.
1012 +
1013 +1. Case Study
1014 +
1015 +User can check this URL for some case studies.
1016 +
1017 +[[http:~~/~~/wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS>>url:http://wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS]]
1018 +
1019 +
1020 +
1021 +
1022 +1. Use AT Command
1023 +11. Access AT Command
1024 +
1025 +RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1026 +
1027 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]]
1028 +
1029 +
1030 +In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1031 +
1032 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]
1033 +
1034 +
1035 +
1036 +More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]]
1037 +
1038 +
1039 +
1040 +1.
1041 +11. Common AT Command Sequence
1042 +111. Multi-channel ABP mode (Use with SX1301/LG308)
1043 +
1044 +If device has not joined network yet:
1045 +
1046 +AT+FDR
1047 +
1048 +AT+NJM=0
1049 +
1050 +ATZ
1051 +
1052 +
1053 +If device already joined network:
1054 +
1055 +AT+NJM=0
1056 +
1057 +ATZ
1058 +
1059 +1.
1060 +11.
1061 +111. Single-channel ABP mode (Use with LG01/LG02)
1062 +
1063 +AT+FDR   Reset Parameters to Factory Default, Keys Reserve
1064 +
1065 +AT+NJM=0 Set to ABP mode
1066 +
1067 +AT+ADR=0 Set the Adaptive Data Rate Off
1068 +
1069 +AT+DR=5  Set Data Rate
1070 +
1071 +AT+TDC=60000  Set transmit interval to 60 seconds
1072 +
1073 +AT+CHS=868400000 Set transmit frequency to 868.4Mhz
1074 +
1075 +AT+RX2FQ=868400000 Set RX2Frequency to 868.4Mhz (according to the result from server)
1076 +
1077 +AT+RX2DR=5  Set RX2DR to match the downlink DR from server. see below
1078 +
1079 +AT+DADDR=26 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1080 +
1081 +ATZ          Reset MCU
1082 +
1083 +**Note:**
1084 +
1085 +1. Make sure the device is set to ABP mode in the IoT Server.
1086 +1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1087 +1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1088 +1. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1089 +
1090 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image029.png]]
1091 +
1092 +
1093 +1. FAQ
1094 +11. How to upgrade the image?
1095 +
1096 +The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to:
1097 +
1098 +* Support new features
1099 +* For bug fix
1100 +* Change LoRaWAN bands.
1101 +
1102 +Below shows the hardware connection for how to upload an image to RS485-BL:
1103 +
1104 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image030.png]]
1105 +
1106 +**Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1107 +
1108 +**Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1109 +
1110 +**Step3: **Open flashloader; choose the correct COM port to update.
1111 +
1112 +
1113 +|(((
1114 +HOLD PRO then press the RST button, SYS will be ON, then click next
1115 +)))
1116 +
1117 +|(((
1118 +Board detected
1119 +)))
1120 +
1121 +|(((
1122 +
1123 +)))
1124 +
1125 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image031.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image032.png]]
1126 +
1127 +
1128 +
1129 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image033.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image034.png]]
1130 +
1131 +
1132 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1133 +
1134 +
1135 +1.
1136 +11. How to change the LoRa Frequency Bands/Region?
1137 +
1138 +User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
1139 +
1140 +
1141 +
1142 +1.
1143 +11. How many RS485-Slave can RS485-BL connects?
1144 +
1145 +The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
1146 +
1147 +
1148 +
1149 +
1150 +1. Trouble Shooting     
1151 +11. Downlink doesn’t work, how to solve it?
1152 +
1153 +Please see this link for debug:
1154 +
1155 +[[http:~~/~~/wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug>>url:http://wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug]] 
1156 +
1157 +
1158 +
1159 +1.
1160 +11. Why I can’t join TTN V3 in US915 /AU915 bands?
1161 +
1162 +It might about the channels mapping. Please see for detail.
1163 +
1164 +[[http:~~/~~/wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band>>url:http://wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band]]
1165 +
1166 +
1167 +
1168 +1. Order Info
1169 +
1170 +**Part Number: RS485-BL-XXX**
1171 +
1172 +**XXX:**
1173 +
1174 +* **EU433**: frequency bands EU433
1175 +* **EU868**: frequency bands EU868
1176 +* **KR920**: frequency bands KR920
1177 +* **CN470**: frequency bands CN470
1178 +* **AS923**: frequency bands AS923
1179 +* **AU915**: frequency bands AU915
1180 +* **US915**: frequency bands US915
1181 +* **IN865**: frequency bands IN865
1182 +* **RU864**: frequency bands RU864
1183 +* **KZ865: **frequency bands KZ865
1184 +
1185 +1. Packing Info
1186 +
1187 +**Package Includes**:
1188 +
1189 +* RS485-BL x 1
1190 +* Stick Antenna for LoRa RF part x 1
1191 +* Program cable x 1
1192 +
1193 +**Dimension and weight**:
1194 +
1195 +* Device Size: 13.5 x 7 x 3 cm
1196 +* Device Weight: 105g
1197 +* Package Size / pcs : 14.5 x 8 x 5 cm
1198 +* Weight / pcs : 170g
1199 +
1200 +1. Support
1201 +
1202 +* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1203 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to
1204 +
1205 +[[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1654157178836-407.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -179.9 KB
Content
1654157342174-798.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -31.9 KB
Content
1654158783574-851.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -40.6 KB
Content
image-20220602153621-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -23.4 KB
Content
image-20220602153621-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -22.2 KB
Content
image-20220602153621-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -22.3 KB
Content
image-20220602155039-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -24.6 KB
Content
image-20220602163333-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -48.2 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0