<
From version < 35.4 >
edited by Xiaoling
on 2022/06/02 15:46
To version < 41.5 >
edited by Xiaoling
on 2022/06/02 16:36
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -77,7 +77,6 @@
77 77  * Packet engine up to 256 bytes with CRC.
78 78  
79 79  
80 -
81 81  == 1.3 Features ==
82 82  
83 83  * LoRaWAN Class A & Class C protocol (default Class C)
... ... @@ -90,7 +90,6 @@
90 90  * Support Interrupt uplink (Since hardware version v1.2)
91 91  
92 92  
93 -
94 94  == 1.4 Applications ==
95 95  
96 96  * Smart Buildings & Home Automation
... ... @@ -101,7 +101,6 @@
101 101  * Smart Factory
102 102  
103 103  
104 -
105 105  == 1.5 Firmware Change log ==
106 106  
107 107  [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
... ... @@ -290,7 +290,6 @@
290 290  )))
291 291  
292 292  
293 -
294 294  === 3.3.2 Configure sensors ===
295 295  
296 296  (((
... ... @@ -309,8 +309,6 @@
309 309  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
310 310  )))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
311 311  
312 -
313 -
314 314  === 3.3.3 Configure read commands for each sampling ===
315 315  
316 316  (((
... ... @@ -362,10 +362,9 @@
362 362  
363 363  * **a: length for the return of AT+COMMAND**
364 364  * **b:1: grab valid value by byte, max 6 bytes. 2: grab valid value by bytes section, max 3 sections.**
365 -* **c: define the position for valid value. **
359 +* **c: define the position for valid value.  **
366 366  )))
367 367  
368 -
369 369  **Examples:**
370 370  
371 371  * Grab bytes:
... ... @@ -389,10 +389,14 @@
389 389  
390 390  (((
391 391  Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.**
385 +
386 +
392 392  )))
393 393  
394 394  (((
395 -(% style="color:#4f81bd" %)**Examples: AT+DATAUP=0**
390 +(% style="color:#037691" %)**Examples: AT+DATAUP=0**
391 +
392 +
396 396  )))
397 397  
398 398  (((
... ... @@ -413,8 +413,10 @@
413 413  
414 414  [[image:1653269759169-150.png||height="513" width="716"]]
415 415  
416 -(% style="color:#4f81bd" %)**Examples: AT+DATAUP=1**
417 417  
414 +(% style="color:#037691" %)**Examples: AT+DATAUP=1**
415 +
416 +
418 418  Compose the uplink payload with value returns in sequence and send with (% style="color:red" %)**Multiply UPLINKs**.
419 419  
420 420  Final Payload is
... ... @@ -421,700 +421,105 @@
421 421  
422 422  (% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA**
423 423  
424 -1. Battery Info (2 bytes): Battery voltage
425 -1. PAYVER (1 byte): Defined by AT+PAYVER
426 -1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling.
427 -1. PAYLOAD# (1 byte): Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
428 -1. DATA: Valid value: max 6 bytes(US915 version here, Notice*!) for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 6 bytes
423 +1. PAYVER: Defined by AT+PAYVER
424 +1. PAYLOAD COUNT: Total how many uplinks of this sampling.
425 +1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
426 +1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes
429 429  
430 -[[image:1653269916228-732.png||height="433" width="711"]]
428 +[[image:image-20220602155039-4.png]]
431 431  
432 432  
433 -So totally there will be 3 uplinks for this sampling, each uplink includes 6 bytes DATA
431 +So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA
434 434  
435 -DATA1=RETURN1 Valid Value = (% style="background-color:green; color:white" %)20 20 0a 33 90 41
433 +DATA1=RETURN1 Valid Value + the first two of Valid value of RETURN10= **20 20 0a 33 90 41 02 aa**
436 436  
437 -DATA2=1^^st^^ ~~ 6^^th^^ byte of Valid value of RETURN10=(% style="background-color:green; color:white" %) 02 aa 05 81 0a 20
435 +DATA2=3^^rd^^ ~~ 10^^th^^ byte of Valid value of RETURN10= **05 81 0a 20 20 20 20 2d**
438 438  
439 -DATA3=7^^th^^ ~~ 11^^th^^ bytes of Valid value of RETURN10 = (% style="background-color:green; color:white" %)20 20 20 2d 30
437 +DATA3=the rest of Valid value of RETURN10= **30**
440 440  
441 -Below are the uplink payloads:
442 442  
443 -[[image:1653270130359-810.png]]
440 +(% style="color:red" %)Notice: In firmware v1.3, the Max bytes has been changed according to the max bytes in different Frequency Bands for lowest SF. As below:
444 444  
442 + ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink.
445 445  
446 -(% style="color:red" %)**Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below:**
444 + * For AU915/AS923 bands, if UplinkDwell time=0, max 11 bytes for each uplink.
447 447  
448 - ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink ( so 51 -5 = 46 max valid date)
446 + * For US915 band, max 11 bytes for each uplink.
449 449  
450 - * For AU915/AS923 bands, if UplinkDwell time=1, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date).
448 + ~* For all other bands: max 51 bytes for each uplink.
451 451  
452 - * For US915 band, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date).
453 453  
454 - ~* For all other bands: max 51 bytes for each uplink  ( so 51 -5 = 46 max valid date).
451 +Below are the uplink payloads:
455 455  
453 +[[image:1654157178836-407.png]]
454 +
455 +
456 456  === 3.3.5 Uplink on demand ===
457 457  
458 -Except uplink periodically, RS485-BL is able to uplink on demand. The server sends downlink command to RS485-BL and RS485 will uplink data base on the command.
458 +Except uplink periodically, RS485-LN is able to uplink on demand. The server send downlink command to RS485-LN and RS485 will uplink data base on the command.
459 459  
460 460  Downlink control command:
461 461  
462 -[[0x08 command>>path:#downlink_08]]: Poll an uplink with current command set in RS485-BL.
462 +**0x08 command**: Poll an uplink with current command set in RS485-LN.
463 463  
464 -[[0xA8 command>>path:#downlink_A8]]: Send a command to RS485-BL and uplink the output from sensors.
464 +**0xA8 command**: Send a command to RS485-LN and uplink the output from sensors.
465 465  
466 466  
467 467  
468 -1.
469 -11.
470 -111. Uplink on Interrupt
468 +=== 3.3.6 Uplink on Interrupt ===
471 471  
472 -Put the interrupt sensor between 3.3v_out and GPIO ext.[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]
470 +RS485-LN support external Interrupt uplink since hardware v1.2 release.
473 473  
474 -AT+INTMOD=0  Disable Interrupt
472 +[[image:1654157342174-798.png]]
475 475  
476 -AT+INTMOD=1  Interrupt trigger by rising or falling edge.
474 +Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet.
477 477  
478 -AT+INTMOD=2  Interrupt trigger by falling edge. ( Default Value)
479 479  
480 -AT+INTMOD=3  Interrupt trigger by rising edge.
477 +== 3.4 Uplink Payload ==
481 481  
482 -
483 -1.
484 -11. Uplink Payload
485 -
486 -|**Size(bytes)**|**2**|**1**|**Length depends on the return from the commands**
487 -|Value|(((
479 +(% border="1" style="background-color:#4bacc6; color:white; width:734px" %)
480 +|**Size(bytes)**|(% style="width:120px" %)**2**|(% style="width:116px" %)**1**|(% style="width:386px" %)**Length depends on the return from the commands**
481 +|Value|(% style="width:120px" %)(((
488 488  Battery(mV)
489 489  
490 490  &
491 491  
492 492  Interrupt _Flag
493 -)))|(((
487 +)))|(% style="width:116px" %)(((
494 494  PAYLOAD_VER
495 495  
496 496  
497 -)))|If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server.
491 +)))|(% style="width:386px" %)If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server.
498 498  
499 499  Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
500 500  
501 501  
502 -function Decoder(bytes, port) {
496 +== 3.5 Configure RS485-BL via AT or Downlink ==
503 503  
504 -~/~/Payload Formats of RS485-BL Deceive
498 +User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands
505 505  
506 -return {
507 -
508 - ~/~/Battery,units:V
509 -
510 - BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000,
511 -
512 - ~/~/GPIO_EXTI 
513 -
514 - EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE",
515 -
516 - ~/~/payload of version
517 -
518 - Pay_ver:bytes[2],
519 -
520 - };
521 -
522 - }
523 -
524 -
525 -
526 -
527 -
528 -
529 -
530 -TTN V3 uplink screen shot.
531 -
532 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
533 -
534 -1.
535 -11. Configure RS485-BL via AT or Downlink
536 -
537 -User can configure RS485-BL via [[AT Commands >>path:#_​Using_the_AT]]or LoRaWAN Downlink Commands
538 -
539 539  There are two kinds of Commands:
540 540  
541 -* **Common Commands**: They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands
502 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
542 542  
543 -* **Sensor Related Commands**: These commands are special designed for RS485-BL.  User can see these commands below:
504 +* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN.  User can see these commands below:
544 544  
545 -1.
546 -11.
547 -111. Common Commands:
506 +=== 3.5.1 Common Commands ===
548 548  
549 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]]
508 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
550 550  
551 551  
552 -1.
553 -11.
554 -111. Sensor related commands:
511 +=== 3.5.2 Sensor related commands ===
555 555  
556 -==== Choose Device Type (RS485 or TTL) ====
513 +Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server.
557 557  
558 -RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect.
515 +[[image:image-20220602163333-5.png||height="263" width="1160"]]
559 559  
560 -* AT Command
517 +The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable)
561 561  
562 -**AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins.
563 563  
564 -**AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins.
520 +3.5.3 Sensor related commands
565 565  
522 +==== ====
566 566  
567 -* Downlink Payload
568 -
569 -**0A aa**     à same as AT+MOD=aa
570 -
571 -
572 -
573 -==== [[RS485 Debug Command>>path:#downlink_A8]] (AT+CFGDEV) ====
574 -
575 -This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling.
576 -
577 -* AT Command
578 -
579 -AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
580 -
581 -m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command.
582 -
583 -
584 -
585 -* Downlink Payload
586 -
587 -Format: A8 MM NN XX XX XX XX YY
588 -
589 -Where:
590 -
591 -* MM: 1: add CRC-16/MODBUS ; 0: no CRC
592 -* NN: The length of RS485 command
593 -* XX XX XX XX: RS485 command total NN bytes
594 -* YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command
595 -
596 -**Example 1:**
597 -
598 -To connect a Modbus Alarm with below commands.
599 -
600 -* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
601 -
602 -* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
603 -
604 -So if user want to use downlink command to control to RS485 Alarm, he can use:
605 -
606 -**A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm
607 -
608 -**A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm
609 -
610 -A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output.
611 -
612 -
613 -**Example 2:**
614 -
615 -Check TTL Sensor return:
616 -
617 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]
618 -
619 -
620 -
621 -
622 -==== Set Payload version ====
623 -
624 -This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
625 -
626 -* AT Command:
627 -
628 -AT+PAYVER: Set PAYVER field = 1
629 -
630 -
631 -* Downlink Payload:
632 -
633 -0xAE 01   à Set PAYVER field =  0x01
634 -
635 -0xAE 0F   à Set PAYVER field =  0x0F
636 -
637 -
638 -==== Set RS485 Sampling Commands ====
639 -
640 -AT+COMMANDx, AT+DATACUTx and AT+SEARCHx
641 -
642 -These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#polling_485]].
643 -
644 -
645 -* AT Command:
646 -
647 -AT+COMMANDx: Configure RS485 read command to sensor.
648 -
649 -AT+DATACUTx: Configure how to handle return from RS485 devices.
650 -
651 -AT+SEARCHx: Configure search command
652 -
653 -
654 -* Downlink Payload:
655 -
656 -0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
657 -
658 -Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
659 -
660 -Format: AF MM NN LL XX XX XX XX YY
661 -
662 -Where:
663 -
664 -* MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
665 -* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
666 -* LL: The length of AT+COMMAND or AT+DATACUT command
667 -* XX XX XX XX: AT+COMMAND or AT+DATACUT command
668 -* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command.
669 -
670 -Example:
671 -
672 -**AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1
673 -
674 -**AF 03 02 06 10 01 05 06 09 0A 00**: Same as AT+DATACUT3=**16**,**1**,**5+6+9+10**
675 -
676 -**AF 03 02 06 0B 02 05 07 08 0A 00**: Same as AT+DATACUT3=**11**,**2**,**5~~7+8~~10**
677 -
678 -
679 -0xAB downlink command can be used for set AT+SEARCHx
680 -
681 -Example: **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So
682 -
683 -* AB aa 01 03 xx xx xx  same as AT+SEARCHaa=1,xx xx xx
684 -* AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands
685 -
686 -**AB aa 02 03 xx xx xx 02 yy yy**  same as **AT+SEARCHaa=2,xx xx xx+yy yy**
687 -
688 -
689 -==== Fast command to handle MODBUS device ====
690 -
691 -AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
692 -
693 -This command is valid since v1.3 firmware version
694 -
695 -
696 -AT+MBFUN has only two value:
697 -
698 -* AT+MBFUN=1: Enable Modbus reading. And get response base on the MODBUS return
699 -
700 -AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore.
701 -
702 -* AT+MBFUN=0: Disable Modbus fast reading.
703 -
704 -Example:
705 -
706 -* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0).
707 -* AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
708 -* AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
709 -
710 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]
711 -
712 -
713 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]
714 -
715 -
716 -* Downlink Commands:
717 -
718 -A9 aa -à Same as AT+MBFUN=aa
719 -
720 -
721 -==== RS485 command timeout ====
722 -
723 -Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action.
724 -
725 -Default value: 0, range:  0 ~~ 5 seconds
726 -
727 -
728 -* AT Command:
729 -
730 -AT+CMDDLaa=hex(bb cc)
731 -
732 -Example:
733 -
734 -**AT+CMDDL1=1000** to send the open time to 1000ms
735 -
736 -
737 -* Downlink Payload:
738 -
739 -0x AA aa bb cc
740 -
741 -Same as: AT+CMDDLaa=hex(bb cc)
742 -
743 - Example:
744 -
745 - 0xAA 01 03 E8  à Same as **AT+CMDDL1=1000 ms**
746 -
747 -
748 -==== [[Uplink>>path:#downlink_A8]] payload mode ====
749 -
750 -Define to use one uplink or multiple uplinks for the sampling.
751 -
752 -The use of this command please see: [[Compose Uplink payload>>path:#DataUP]]
753 -
754 -* AT Command:
755 -
756 -AT+DATAUP=0
757 -
758 -AT+DATAUP=1
759 -
760 -
761 -* Downlink Payload:
762 -
763 -0xAD 00   à Same as AT+DATAUP=0
764 -
765 -0xAD 01   à Same as AT+DATAUP=1
766 -
767 -
768 -==== Manually trigger an Uplink ====
769 -
770 -Ask device to send an uplink immediately.
771 -
772 -* Downlink Payload:
773 -
774 -0x08 FF, RS485-BL will immediately send an uplink.
775 -
776 -
777 -==== Clear RS485 Command ====
778 -
779 -The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
780 -
781 -
782 -* AT Command:
783 -
784 -**AT+CMDEAR=mm,nn**   mm: start position of erase ,nn: stop position of erase
785 -
786 -Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
787 -
788 -Example screen shot after clear all RS485 commands. 
789 -
790 -
791 -
792 -The uplink screen shot is:
793 -
794 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
795 -
796 -
797 -* Downlink Payload:
798 -
799 -0x09 aa bb same as AT+CMDEAR=aa,bb
800 -
801 -
802 -==== Set Serial Communication Parameters ====
803 -
804 -Set the Rs485 serial communication parameters:
805 -
806 -* AT Command:
807 -
808 -Set Baud Rate:
809 -
810 -AT+BAUDR=9600    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
811 -
812 -
813 -Set UART parity
814 -
815 -AT+PARITY=0    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
816 -
817 -
818 -Set STOPBIT
819 -
820 -AT+STOPBIT=0    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
821 -
822 -
823 -* Downlink Payload:
824 -
825 -A7 01 aa bb: Same  AT+BAUDR=hex(aa bb)*100
826 -
827 -Example:
828 -
829 -* A7 01 00 60   same as AT+BAUDR=9600
830 -* A7 01 04 80  same as AT+BAUDR=115200
831 -
832 -A7 02 aa: Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
833 -
834 -A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
835 -
836 -
837 -==== Control output power duration ====
838 -
839 -User can set the output power duration before each sampling.
840 -
841 -* AT Command:
842 -
843 -Example:
844 -
845 -AT+3V3T=1000 ~/~/ 3V3 output power will open 1s before each sampling.
846 -
847 -AT+5VT=1000 ~/~/ +5V output power will open 1s before each sampling.
848 -
849 -
850 -* LoRaWAN Downlink Command:
851 -
852 -07 01 aa bb  Same as AT+5VT=(aa bb)
853 -
854 -07 02 aa bb  Same as AT+3V3T=(aa bb)
855 -
856 -
857 -
858 -
859 -1.
860 -11. Buttons
861 -
862 -|**Button**|**Feature**
863 -|**RST**|Reboot RS485-BL
864 -
865 -1.
866 -11. +3V3 Output
867 -
868 -RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
869 -
870 -The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 
871 -
872 -
873 -The +3V3 output time can be controlled by AT Command.
874 -
875 -**AT+3V3T=1000**
876 -
877 -Means set +3v3 valid time to have 1000ms. So, the real +3v3 output will actually have 1000ms + sampling time for other sensors.
878 -
879 -
880 -By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
881 -
882 -
883 -1.
884 -11. +5V Output
885 -
886 -RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
887 -
888 -The +5V output will be valid for every sampling. RS485-BL will enable +5V output before all sampling and disable the +5v after all sampling. 
889 -
890 -
891 -The 5V output time can be controlled by AT Command.
892 -
893 -**AT+5VT=1000**
894 -
895 -Means set 5V valid time to have 1000ms. So, the real 5V output will actually have 1000ms + sampling time for other sensors.
896 -
897 -
898 -By default, the AT+5VT=0. If the external sensor which require 5v and require more time to get stable state, user can use this command to increase the power ON duration for this sensor.
899 -
900 -
901 -
902 -
903 -1.
904 -11. LEDs
905 -
906 -|**LEDs**|**Feature**
907 -|**LED1**|Blink when device transmit a packet.
908 -
909 -1.
910 -11. Switch Jumper
911 -
912 -|**Switch Jumper**|**Feature**
913 -|**SW1**|(((
914 -ISP position: Upgrade firmware via UART
915 -
916 -Flash position: Configure device, check running status.
917 -)))
918 -|**SW2**|(((
919 -5V position: set to compatible with 5v I/O.
920 -
921 -3.3v position: set to compatible with 3.3v I/O.,
922 -)))
923 -
924 -+3.3V: is always ON
925 -
926 -+5V: Only open before every sampling. The time is by default, it is AT+5VT=0.  Max open time. 5000 ms.
927 -
928 -1. Case Study
929 -
930 -User can check this URL for some case studies.
931 -
932 -[[http:~~/~~/wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS>>url:http://wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS]]
933 -
934 -
935 -
936 -
937 -1. Use AT Command
938 -11. Access AT Command
939 -
940 -RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
941 -
942 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]]
943 -
944 -
945 -In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
946 -
947 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]
948 -
949 -
950 -
951 -More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]]
952 -
953 -
954 -
955 -1.
956 -11. Common AT Command Sequence
957 -111. Multi-channel ABP mode (Use with SX1301/LG308)
958 -
959 -If device has not joined network yet:
960 -
961 -AT+FDR
962 -
963 -AT+NJM=0
964 -
965 -ATZ
966 -
967 -
968 -If device already joined network:
969 -
970 -AT+NJM=0
971 -
972 -ATZ
973 -
974 -1.
975 -11.
976 -111. Single-channel ABP mode (Use with LG01/LG02)
977 -
978 -AT+FDR   Reset Parameters to Factory Default, Keys Reserve
979 -
980 -AT+NJM=0 Set to ABP mode
981 -
982 -AT+ADR=0 Set the Adaptive Data Rate Off
983 -
984 -AT+DR=5  Set Data Rate
985 -
986 -AT+TDC=60000  Set transmit interval to 60 seconds
987 -
988 -AT+CHS=868400000 Set transmit frequency to 868.4Mhz
989 -
990 -AT+RX2FQ=868400000 Set RX2Frequency to 868.4Mhz (according to the result from server)
991 -
992 -AT+RX2DR=5  Set RX2DR to match the downlink DR from server. see below
993 -
994 -AT+DADDR=26 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
995 -
996 -ATZ          Reset MCU
997 -
998 -**Note:**
999 -
1000 -1. Make sure the device is set to ABP mode in the IoT Server.
1001 -1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1002 -1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1003 -1. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1004 -
1005 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image029.png]]
1006 -
1007 -
1008 -1. FAQ
1009 -11. How to upgrade the image?
1010 -
1011 -The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to:
1012 -
1013 -* Support new features
1014 -* For bug fix
1015 -* Change LoRaWAN bands.
1016 -
1017 -Below shows the hardware connection for how to upload an image to RS485-BL:
1018 -
1019 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image030.png]]
1020 -
1021 -**Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1022 -
1023 -**Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1024 -
1025 -**Step3: **Open flashloader; choose the correct COM port to update.
1026 -
1027 -
1028 -|(((
1029 -HOLD PRO then press the RST button, SYS will be ON, then click next
1030 -)))
1031 -
1032 -|(((
1033 -Board detected
1034 -)))
1035 -
1036 -|(((
1037 -
1038 -)))
1039 -
1040 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image031.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image032.png]]
1041 -
1042 -
1043 -
1044 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image033.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image034.png]]
1045 -
1046 -
1047 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1048 -
1049 -
1050 -1.
1051 -11. How to change the LoRa Frequency Bands/Region?
1052 -
1053 -User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
1054 -
1055 -
1056 -
1057 -1.
1058 -11. How many RS485-Slave can RS485-BL connects?
1059 -
1060 -The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
1061 -
1062 -
1063 -
1064 -
1065 -1. Trouble Shooting     
1066 -11. Downlink doesn’t work, how to solve it?
1067 -
1068 -Please see this link for debug:
1069 -
1070 -[[http:~~/~~/wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug>>url:http://wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug]] 
1071 -
1072 -
1073 -
1074 -1.
1075 -11. Why I can’t join TTN V3 in US915 /AU915 bands?
1076 -
1077 -It might about the channels mapping. Please see for detail.
1078 -
1079 -[[http:~~/~~/wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band>>url:http://wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band]]
1080 -
1081 -
1082 -
1083 -1. Order Info
1084 -
1085 -**Part Number: RS485-BL-XXX**
1086 -
1087 -**XXX:**
1088 -
1089 -* **EU433**: frequency bands EU433
1090 -* **EU868**: frequency bands EU868
1091 -* **KR920**: frequency bands KR920
1092 -* **CN470**: frequency bands CN470
1093 -* **AS923**: frequency bands AS923
1094 -* **AU915**: frequency bands AU915
1095 -* **US915**: frequency bands US915
1096 -* **IN865**: frequency bands IN865
1097 -* **RU864**: frequency bands RU864
1098 -* **KZ865: **frequency bands KZ865
1099 -
1100 -1. Packing Info
1101 -
1102 -**Package Includes**:
1103 -
1104 -* RS485-BL x 1
1105 -* Stick Antenna for LoRa RF part x 1
1106 -* Program cable x 1
1107 -
1108 -**Dimension and weight**:
1109 -
1110 -* Device Size: 13.5 x 7 x 3 cm
1111 -* Device Weight: 105g
1112 -* Package Size / pcs : 14.5 x 8 x 5 cm
1113 -* Weight / pcs : 170g
1114 -
1115 -1. Support
1116 -
1117 -* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1118 -* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to
1119 -
1120 -[[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
524 +==== ====
1654157178836-407.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +179.9 KB
Content
1654157342174-798.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +31.9 KB
Content
1654158783574-851.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +40.6 KB
Content
image-20220602155039-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +24.6 KB
Content
image-20220602163333-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +48.2 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0