Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Karry Zhuang on 2025/03/06 16:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -222,8 +222,6 @@ 222 222 223 223 ((( 224 224 (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1 225 - 226 - 227 227 ))) 228 228 ))) 229 229 ... ... @@ -231,19 +231,19 @@ 231 231 232 232 To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are: 233 233 234 -(% border="1" style="background-color:#ffffcc; color:green; width:7 82px" %)235 -|( % style="width:128px" %)(((232 +(% border="1" style="background-color:#ffffcc; color:green; width:795px" %) 233 +|((( 236 236 **AT Commands** 237 -)))|(% style="width: 305px" %)(((235 +)))|(% style="width:285px" %)((( 238 238 **Description** 239 -)))|(% style="width:34 6px" %)(((237 +)))|(% style="width:347px" %)((( 240 240 **Example** 241 241 ))) 242 -|( % style="width:128px" %)(((240 +|((( 243 243 AT+BAUDR 244 -)))|(% style="width: 305px" %)(((242 +)))|(% style="width:285px" %)((( 245 245 Set the baud rate (for RS485 connection). Default Value is: 9600. 246 -)))|(% style="width:34 6px" %)(((244 +)))|(% style="width:347px" %)((( 247 247 ((( 248 248 AT+BAUDR=9600 249 249 ))) ... ... @@ -252,11 +252,11 @@ 252 252 Options: (1200,2400,4800,14400,19200,115200) 253 253 ))) 254 254 ))) 255 -|( % style="width:128px" %)(((253 +|((( 256 256 AT+PARITY 257 -)))|(% style="width: 305px" %)(((255 +)))|(% style="width:285px" %)((( 258 258 Set UART parity (for RS485 connection) 259 -)))|(% style="width:34 6px" %)(((257 +)))|(% style="width:347px" %)((( 260 260 ((( 261 261 AT+PARITY=0 262 262 ))) ... ... @@ -265,9 +265,9 @@ 265 265 Option: 0: no parity, 1: odd parity, 2: even parity 266 266 ))) 267 267 ))) 268 -|( % style="width:128px" %)(((266 +|((( 269 269 AT+STOPBIT 270 -)))|(% style="width: 305px" %)(((268 +)))|(% style="width:285px" %)((( 271 271 ((( 272 272 Set serial stopbit (for RS485 connection) 273 273 ))) ... ... @@ -275,7 +275,7 @@ 275 275 ((( 276 276 277 277 ))) 278 -)))|(% style="width:34 6px" %)(((276 +)))|(% style="width:347px" %)((( 279 279 ((( 280 280 AT+STOPBIT=0 for 1bit 281 281 ))) ... ... @@ -289,7 +289,6 @@ 289 289 ))) 290 290 ))) 291 291 292 - 293 293 === 3.3.2 Configure sensors === 294 294 295 295 (((