Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Karry Zhuang on 2025/03/06 16:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -212,6 +212,7 @@ 212 212 213 213 [[image:1652953568895-172.png||height="232" width="724"]] 214 214 215 + 215 215 == 3.3 Configure Commands to read data == 216 216 217 217 ((( ... ... @@ -221,6 +221,8 @@ 221 221 222 222 ((( 223 223 (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1 225 + 226 + 224 224 ))) 225 225 ))) 226 226 ... ... @@ -228,19 +228,19 @@ 228 228 229 229 To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are: 230 230 231 -(% border="1" style="background-color:#ffffcc; color:green; width:7 95px" %)232 -|((( 234 +(% border="1" style="background-color:#ffffcc; color:green; width:782px" %) 235 +|(% style="width:128px" %)((( 233 233 **AT Commands** 234 -)))|(% style="width: 285px" %)(((237 +)))|(% style="width:305px" %)((( 235 235 **Description** 236 -)))|(% style="width:34 7px" %)(((239 +)))|(% style="width:346px" %)((( 237 237 **Example** 238 238 ))) 239 -|((( 242 +|(% style="width:128px" %)((( 240 240 AT+BAUDR 241 -)))|(% style="width: 285px" %)(((244 +)))|(% style="width:305px" %)((( 242 242 Set the baud rate (for RS485 connection). Default Value is: 9600. 243 -)))|(% style="width:34 7px" %)(((246 +)))|(% style="width:346px" %)((( 244 244 ((( 245 245 AT+BAUDR=9600 246 246 ))) ... ... @@ -249,11 +249,11 @@ 249 249 Options: (1200,2400,4800,14400,19200,115200) 250 250 ))) 251 251 ))) 252 -|((( 255 +|(% style="width:128px" %)((( 253 253 AT+PARITY 254 -)))|(% style="width: 285px" %)(((257 +)))|(% style="width:305px" %)((( 255 255 Set UART parity (for RS485 connection) 256 -)))|(% style="width:34 7px" %)(((259 +)))|(% style="width:346px" %)((( 257 257 ((( 258 258 AT+PARITY=0 259 259 ))) ... ... @@ -262,9 +262,9 @@ 262 262 Option: 0: no parity, 1: odd parity, 2: even parity 263 263 ))) 264 264 ))) 265 -|((( 268 +|(% style="width:128px" %)((( 266 266 AT+STOPBIT 267 -)))|(% style="width: 285px" %)(((270 +)))|(% style="width:305px" %)((( 268 268 ((( 269 269 Set serial stopbit (for RS485 connection) 270 270 ))) ... ... @@ -272,7 +272,7 @@ 272 272 ((( 273 273 274 274 ))) 275 -)))|(% style="width:34 7px" %)(((278 +)))|(% style="width:346px" %)((( 276 276 ((( 277 277 AT+STOPBIT=0 for 1bit 278 278 ))) ... ... @@ -286,6 +286,7 @@ 286 286 ))) 287 287 ))) 288 288 292 + 289 289 === 3.3.2 Configure sensors === 290 290 291 291 (((