Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Karry Zhuang on 2025/03/06 16:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 8 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -18,26 +18,30 @@ 18 18 19 19 ((( 20 20 ((( 21 -The Dragino RS485-LN is a RS485 to LoRaWAN Converter. It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost. 21 +The Dragino RS485-LN is a (% style="color:blue" %)**RS485 to LoRaWAN Converter**(%%). It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost. 22 22 ))) 23 23 24 24 ((( 25 -RS485-LN allows user to monitor / control RS485 devices and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on. 25 +RS485-LN allows user to (% style="color:blue" %)**monitor / control RS485 devices**(%%) and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on. 26 26 ))) 27 27 28 28 ((( 29 -For data uplink, RS485-LN sends user-defined commands to RS485 devices and gets the return from the RS485 devices. RS485-LN will process these returns according to user-define rules to get the final payload and upload to LoRaWAN server. 29 +(% style="color:blue" %)**For data uplink**(%%), RS485-LN sends user-defined commands to RS485 devices and gets the return from the RS485 devices. RS485-LN will process these returns according to user-define rules to get the final payload and upload to LoRaWAN server. 30 30 ))) 31 31 32 32 ((( 33 -For data downlink, RS485-LN runs in LoRaWAN Class C. When there downlink commands from LoRaWAN server, RS485-LN will forward the commands from LoRaWAN server to RS485 devices. 33 +(% style="color:blue" %)**For data downlink**(%%), RS485-LN runs in LoRaWAN Class C. When there downlink commands from LoRaWAN server, RS485-LN will forward the commands from LoRaWAN server to RS485 devices. 34 + 35 +(% style="color:blue" %)**Demo Dashboard for RS485-LN**(%%) connect to two energy meters: [[https:~~/~~/app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a>>url:https://app.datacake.de/dashboard/d/58844a26-378d-4c5a-aaf5-b5b5b153447a]] 34 34 ))) 35 35 ))) 36 36 37 37 [[image:1653267211009-519.png||height="419" width="724"]] 38 38 41 + 39 39 == 1.2 Specifications == 40 40 44 + 41 41 **Hardware System:** 42 42 43 43 * STM32L072CZT6 MCU ... ... @@ -44,8 +44,6 @@ 44 44 * SX1276/78 Wireless Chip 45 45 * Power Consumption (exclude RS485 device): 46 46 ** Idle: 32mA@12v 47 - 48 -* 49 49 ** 20dB Transmit: 65mA@12v 50 50 51 51 **Interface for Model:** ... ... @@ -74,6 +74,7 @@ 74 74 * Automatic RF Sense and CAD with ultra-fast AFC. 75 75 * Packet engine up to 256 bytes with CRC. 76 76 79 + 77 77 == 1.3 Features == 78 78 79 79 * LoRaWAN Class A & Class C protocol (default Class C) ... ... @@ -98,6 +98,7 @@ 98 98 99 99 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] 100 100 104 + 101 101 == 1.6 Hardware Change log == 102 102 103 103 ((( ... ... @@ -105,6 +105,8 @@ 105 105 v1.2: Add External Interrupt Pin. 106 106 107 107 v1.0: Release 112 + 113 + 108 108 ))) 109 109 ))) 110 110 ... ... @@ -121,6 +121,8 @@ 121 121 ))) 122 122 123 123 [[image:1653268091319-405.png]] 130 + 131 + 124 124 ))) 125 125 126 126 = 3. Operation Mode = ... ... @@ -129,6 +129,8 @@ 129 129 130 130 ((( 131 131 The RS485-LN is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-LN. It will auto join the network via OTAA. 140 + 141 + 132 132 ))) 133 133 134 134 == 3.2 Example to join LoRaWAN network == ... ... @@ -137,10 +137,15 @@ 137 137 138 138 [[image:1653268155545-638.png||height="334" width="724"]] 139 139 150 + 140 140 ((( 152 +((( 141 141 The RS485-LN in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method. The connection is as below: 154 +))) 142 142 156 +((( 143 143 485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively. 158 +))) 144 144 145 145 [[image:1653268227651-549.png||height="592" width="720"]] 146 146 ... ... @@ -192,6 +192,7 @@ 192 192 193 193 [[image:1652953568895-172.png||height="232" width="724"]] 194 194 210 + 195 195 == 3.3 Configure Commands to read data == 196 196 197 197 ((( ... ... @@ -201,6 +201,8 @@ 201 201 202 202 ((( 203 203 (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1 220 + 221 + 204 204 ))) 205 205 ))) 206 206 ... ... @@ -208,19 +208,19 @@ 208 208 209 209 To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are: 210 210 211 -(% border="1" style="background-color:#ffffcc; color:green; width:7 95px" %)212 -|((( 229 +(% border="1" style="background-color:#ffffcc; color:green; width:782px" %) 230 +|(% style="width:128px" %)((( 213 213 **AT Commands** 214 -)))|(% style="width: 285px" %)(((232 +)))|(% style="width:305px" %)((( 215 215 **Description** 216 -)))|(% style="width:34 7px" %)(((234 +)))|(% style="width:346px" %)((( 217 217 **Example** 218 218 ))) 219 -|((( 237 +|(% style="width:128px" %)((( 220 220 AT+BAUDR 221 -)))|(% style="width: 285px" %)(((239 +)))|(% style="width:305px" %)((( 222 222 Set the baud rate (for RS485 connection). Default Value is: 9600. 223 -)))|(% style="width:34 7px" %)(((241 +)))|(% style="width:346px" %)((( 224 224 ((( 225 225 AT+BAUDR=9600 226 226 ))) ... ... @@ -229,11 +229,11 @@ 229 229 Options: (1200,2400,4800,14400,19200,115200) 230 230 ))) 231 231 ))) 232 -|((( 250 +|(% style="width:128px" %)((( 233 233 AT+PARITY 234 -)))|(% style="width: 285px" %)(((252 +)))|(% style="width:305px" %)((( 235 235 Set UART parity (for RS485 connection) 236 -)))|(% style="width:34 7px" %)(((254 +)))|(% style="width:346px" %)((( 237 237 ((( 238 238 AT+PARITY=0 239 239 ))) ... ... @@ -242,9 +242,9 @@ 242 242 Option: 0: no parity, 1: odd parity, 2: even parity 243 243 ))) 244 244 ))) 245 -|((( 263 +|(% style="width:128px" %)((( 246 246 AT+STOPBIT 247 -)))|(% style="width: 285px" %)(((265 +)))|(% style="width:305px" %)((( 248 248 ((( 249 249 Set serial stopbit (for RS485 connection) 250 250 ))) ... ... @@ -252,7 +252,7 @@ 252 252 ((( 253 253 254 254 ))) 255 -)))|(% style="width:34 7px" %)(((273 +)))|(% style="width:346px" %)((( 256 256 ((( 257 257 AT+STOPBIT=0 for 1bit 258 258 ))) ... ... @@ -287,77 +287,34 @@ 287 287 === 3.3.3 Configure read commands for each sampling === 288 288 289 289 ((( 290 -RS485-BL is a battery powered device; it will sleep most of time. And wake up on each period and read RS485 / TTL sensor data and uplink. 291 -))) 308 +During each sampling, we need confirm what commands we need to send to the RS485 sensors to read data. After the RS485 sensors send back the value, it normally include some bytes and we only need a few from them for a shorten payload. 292 292 293 -((( 294 -During each sampling, we need to confirm what commands we need to send to the sensors to read data. After the RS485/TTL sensors send back the value, it normally includes some bytes and we only need a few from them for a shorten payload. 295 -))) 296 - 297 -((( 298 298 To save the LoRaWAN network bandwidth, we might need to read data from different sensors and combine their valid value into a short payload. 299 -))) 300 300 301 -((( 302 302 This section describes how to achieve above goals. 303 -))) 304 304 305 -((( 306 -During each sampling, the RS485-BL can support 15 commands to read sensors. And combine the return to one or several uplink payloads. 307 -))) 314 +During each sampling, the RS485-LN can support 15 commands to read sensors. And combine the return to one or several uplink payloads. 308 308 309 -((( 310 -**Command from RS485-BL to Sensor:** 311 -))) 312 312 313 -((( 314 -RS485-BL can send out pre-set max 15 strings via **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF** . All commands are of same grammar. 315 -))) 317 +**Each RS485 commands include two parts:** 316 316 317 -((( 318 -**Handle return from sensors to RS485-BL**: 319 -))) 319 +~1. What commands RS485-LN will send to the RS485 sensors. There are total 15 commands from **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF**. All commands are of same grammar. 320 320 321 -((( 322 -After RS485-BL send out a string to sensor, RS485-BL will wait for the return from RS485 or TTL sensor. And user can specify how to handle the return, by **AT+DATACUT or AT+SEARCH commands** 323 -))) 321 +2. How to get wanted value the from RS485 sensors returns from by 1). There are total 15 AT Commands to handle the return, commands are **AT+DATACUT1**,**AT+DATACUT2**,…, **AT+DATACUTF** corresponding to the commands from 1). All commands are of same grammar. 324 324 325 -* ((( 326 -**AT+DATACUT** 327 -))) 323 +3. Some RS485 device might has longer delay on reply, so user can use AT+CMDDL to set the timeout for getting reply after the RS485 command is sent. For example **AT+CMDDL1=1000** to send the open time to 1000ms 328 328 329 -((( 330 -When the return value from sensor have fix length and we know which position the valid value we should get, we can use AT+DATACUT command. 331 -))) 332 332 333 -* ((( 334 -**AT+SEARCH** 335 -))) 336 - 337 -((( 338 -When the return value from sensor is dynamic length and we are not sure which bytes the valid data is, instead, we know what value the valid value following. We can use AT+SEARCH to search the valid value in the return string. 339 -))) 340 - 341 -((( 342 -**Define wait timeout:** 343 -))) 344 - 345 -((( 346 -Some RS485 device might has longer delay on reply, so user can use AT+CMDDL to set the timeout for getting reply after the RS485 command is sent. For example, AT+CMDDL1=1000 to send the open time to 1000ms 347 -))) 348 - 349 -((( 350 350 After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**. 351 -))) 352 352 353 -**Examples:** 354 354 355 355 Below are examples for the how above AT Commands works. 356 356 357 -**AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is: 358 358 359 -(% border="1" class="table-bordered" %) 360 -|((( 332 +**AT+COMMANDx : **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is: 333 + 334 +(% border="1" style="background-color:#4bacc6; color:white; width:499px" %) 335 +|(% style="width:496px" %)((( 361 361 **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m** 362 362 363 363 **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent** ... ... @@ -365,49 +365,15 @@ 365 365 **m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command** 366 366 ))) 367 367 368 -((( 369 369 For example, if we have a RS485 sensor. The command to get sensor value is: 01 03 0B B8 00 02 46 0A. Where 01 03 0B B8 00 02 is the Modbus command to read the register 0B B8 where stored the sensor value. The 46 0A is the CRC-16/MODBUS which calculate manually. 370 -))) 371 371 372 -((( 373 -In the RS485-BL, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same. 374 -))) 345 +In the RS485-LN, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same. 375 375 376 -((( 377 -**AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx. 378 -))) 379 379 380 -(% border="1" class="table-bordered" %) 381 -|((( 382 -**AT+SEARCHx=aa,xx xx xx xx xx** 383 - 384 -* **aa: 1: prefix match mode; 2: prefix and suffix match mode** 385 -* **xx xx xx xx xx: match string. Max 5 bytes for prefix and 5 bytes for suffix** 386 - 387 - 388 -))) 389 - 390 -**Examples:** 391 - 392 -~1. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 393 - 394 -If we set AT+SEARCH1=1,1E 56 34. (max 5 bytes for prefix) 395 - 396 -The valid data will be all bytes after 1E 56 34 , so it is (% style="background-color:yellow" %)** 2e 30 58 5f 36 41 30 31 00 49** 397 - 398 -[[image:1653269403619-508.png]] 399 - 400 -2. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 401 - 402 -If we set AT+SEARCH1=2, 1E 56 34+31 00 49 403 - 404 -Device will search the bytes between 1E 56 34 and 31 00 49. So it is (% style="background-color:yellow" %)** 2e 30 58 5f 36 41 30** 405 - 406 -[[image:1653269438444-278.png]] 407 - 408 408 **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes. 409 409 410 -|((( 350 +(% border="1" style="background-color:#4bacc6; color:white; width:725px" %) 351 +|(% style="width:722px" %)((( 411 411 **AT+DATACUTx=a,b,c** 412 412 413 413 * **a: length for the return of AT+COMMAND** ... ... @@ -415,48 +415,37 @@ 415 415 * **c: define the position for valid value. ** 416 416 ))) 417 417 418 -Examples: 359 +**Examples:** 419 419 420 420 * Grab bytes: 421 421 422 -[[image: 1653269551753-223.png||height="311" width="717"]]363 +[[image:image-20220602153621-1.png]] 423 423 365 + 424 424 * Grab a section. 425 425 426 -[[image: 1653269568276-930.png||height="325" width="718"]]368 +[[image:image-20220602153621-2.png]] 427 427 370 + 428 428 * Grab different sections. 429 429 430 -[[image: 1653269593172-426.png||height="303" width="725"]]373 +[[image:image-20220602153621-3.png]] 431 431 432 -(% style="color:red" %)**Note:** 375 + 376 +))) 433 433 434 -AT+SEARCHx and AT+DATACUTx can be used together, if both commands are set, RS485-BL will first process AT+SEARCHx on the return string and get a temporary string, and then process AT+DATACUTx on this temporary string to get the final payload. In this case, AT+DATACUTx need to set to format AT+DATACUTx=0,xx,xx where the return bytes set to 0. 435 - 436 -Example: 437 - 438 -(% style="color:red" %)AT+COMMAND1=11 01 1E D0,0 439 - 440 -(% style="color:red" %)AT+SEARCH1=1,1E 56 34 441 - 442 -(% style="color:red" %)AT+DATACUT1=0,2,1~~5 443 - 444 -(% style="color:red" %)Return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 445 - 446 -(% style="color:red" %)String after SEARCH command: 2e 30 58 5f 36 41 30 31 00 49 447 - 448 -(% style="color:red" %)Valid payload after DataCUT command: 2e 30 58 5f 36 449 - 450 -[[image:1653269618463-608.png]] 451 - 452 452 === 3.3.4 Compose the uplink payload === 453 453 454 454 ((( 455 455 Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.** 382 + 383 + 456 456 ))) 457 457 458 458 ((( 459 -(% style="color:#4f81bd" %)**Examples: AT+DATAUP=0** 387 +(% style="color:#037691" %)**Examples: AT+DATAUP=0** 388 + 389 + 460 460 ))) 461 461 462 462 ((( ... ... @@ -477,8 +477,10 @@ 477 477 478 478 [[image:1653269759169-150.png||height="513" width="716"]] 479 479 480 -(% style="color:#4f81bd" %)**Examples: AT+DATAUP=1** 481 481 411 +(% style="color:#037691" %)**Examples: AT+DATAUP=1** 412 + 413 + 482 482 Compose the uplink payload with value returns in sequence and send with (% style="color:red" %)**Multiply UPLINKs**. 483 483 484 484 Final Payload is ... ... @@ -485,700 +485,105 @@ 485 485 486 486 (% style="color:#4f81bd" %)**Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA** 487 487 488 -1. Battery Info (2 bytes): Battery voltage 489 -1. PAYVER (1 byte): Defined by AT+PAYVER 490 -1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling. 491 -1. PAYLOAD# (1 byte): Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT) 492 -1. DATA: Valid value: max 6 bytes(US915 version here, Notice*!) for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 6 bytes 420 +1. PAYVER: Defined by AT+PAYVER 421 +1. PAYLOAD COUNT: Total how many uplinks of this sampling. 422 +1. PAYLOAD#: Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT) 423 +1. DATA: Valid value: max 8 bytes for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 8 bytes 493 493 494 -[[image: 1653269916228-732.png||height="433" width="711"]]425 +[[image:image-20220602155039-4.png]] 495 495 496 496 497 -So totally there will be 3 uplinks for this sampling, each uplink include s6bytes DATA428 +So totally there will be 3 uplinks for this sampling, each uplink include 8 bytes DATA 498 498 499 -DATA1=RETURN1 Valid Value =(% style="background-color:green;color:white"%)20 20 0a 33 90 41430 +DATA1=RETURN1 Valid Value + the first two of Valid value of RETURN10= **20 20 0a 33 90 41 02 aa** 500 500 501 -DATA2= 1^^st^^ ~~6^^th^^ byte of Valid value of RETURN10=(%style="background-color:green;color:white"%)02aa05810a20432 +DATA2=3^^rd^^ ~~ 10^^th^^ byte of Valid value of RETURN10= **05 81 0a 20 20 20 20 2d** 502 502 503 -DATA3= 7^^th^^~~ 11^^th^^ bytes of Valid value of RETURN10(%style="background-color:green; color:white" %)20 20 20 2d30434 +DATA3=the rest of Valid value of RETURN10= **30** 504 504 505 -Below are the uplink payloads: 506 506 507 - [[image:1653270130359-810.png]]437 +(% style="color:red" %)Notice: In firmware v1.3, the Max bytes has been changed according to the max bytes in different Frequency Bands for lowest SF. As below: 508 508 439 + ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink. 509 509 510 - (%style="color:red"%)**Notice:theMaxbytes is accordingto the maxsupportbytesin differentFrequencyBands forlowest SF.As below:**441 + * For AU915/AS923 bands, if UplinkDwell time=0, max 11 bytes for each uplink. 511 511 512 - ~*AU915/AS923bands,if UplinkDwell time=0, max51 bytes( so 51 -5 = 46 max valid date)443 + * For US915 band, max 11 bytes for each uplink. 513 513 514 - * AU915/AS923bands,if UplinkDwell time=1, max 11bytes for each uplink( so 11 -5 = 6 max valid date).445 + ~* For all other bands: max 51 bytes for each uplink. 515 515 516 - * For US915 band, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date). 517 517 518 - ~* Forallotherbands: max 51 bytes for eachuplink( so 51 -5 = 46 max valid date).448 +Below are the uplink payloads: 519 519 450 +[[image:1654157178836-407.png]] 451 + 452 + 520 520 === 3.3.5 Uplink on demand === 521 521 522 -Except uplink periodically, RS485- BL is able to uplink on demand. The server sendsdownlink command to RS485-BL and RS485 will uplink data base on the command.455 +Except uplink periodically, RS485-LN is able to uplink on demand. The server send downlink command to RS485-LN and RS485 will uplink data base on the command. 523 523 524 524 Downlink control command: 525 525 526 - [[0x08 command>>path:#downlink_08]]:Poll an uplink with current command set in RS485-BL.459 +**0x08 command**: Poll an uplink with current command set in RS485-LN. 527 527 528 - [[0xA8 command>>path:#downlink_A8]]:Send a command to RS485-BL and uplink the output from sensors.461 +**0xA8 command**: Send a command to RS485-LN and uplink the output from sensors. 529 529 530 530 531 531 532 -1. 533 -11. 534 -111. Uplink on Interrupt 465 +=== 3.3.6 Uplink on Interrupt === 535 535 536 - Put theinterruptsensorbetween3.3v_outand GPIOext.[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]467 +RS485-LN support external Interrupt uplink since hardware v1.2 release. 537 537 538 - AT+INTMOD=0 DisableInterrupt469 +[[image:1654157342174-798.png]] 539 539 540 - AT+INTMOD=1Interrupt triggerbyrising orfallingedge.471 +Connect the Interrupt pin to RS485-LN INT port and connect the GND pin to V- port. When there is a high voltage (Max 24v) on INT pin. Device will send an uplink packet. 541 541 542 -AT+INTMOD=2 Interrupt trigger by falling edge. ( Default Value) 543 543 544 - AT+INTMOD=3Interrupt trigger by risingedge.474 +== 3.4 Uplink Payload == 545 545 546 - 547 -1. 548 -11. Uplink Payload 549 - 550 -|**Size(bytes)**|**2**|**1**|**Length depends on the return from the commands** 551 -|Value|((( 476 +(% border="1" style="background-color:#4bacc6; color:white; width:734px" %) 477 +|**Size(bytes)**|(% style="width:120px" %)**2**|(% style="width:116px" %)**1**|(% style="width:386px" %)**Length depends on the return from the commands** 478 +|Value|(% style="width:120px" %)((( 552 552 Battery(mV) 553 553 554 554 & 555 555 556 556 Interrupt _Flag 557 -)))|((( 484 +)))|(% style="width:116px" %)((( 558 558 PAYLOAD_VER 559 559 560 560 561 -)))|If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server. 488 +)))|(% style="width:386px" %)If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server. 562 562 563 563 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors. 564 564 565 565 566 -fu nctionDecoder(bytes,port){493 +== 3.5 Configure RS485-BL via AT or Downlink == 567 567 568 - ~/~/Payload Formatsof RS485-BL Deceive495 +User can configure RS485-LN via AT Commands or LoRaWAN Downlink Commands 569 569 570 -return { 571 - 572 - ~/~/Battery,units:V 573 - 574 - BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000, 575 - 576 - ~/~/GPIO_EXTI 577 - 578 - EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE", 579 - 580 - ~/~/payload of version 581 - 582 - Pay_ver:bytes[2], 583 - 584 - }; 585 - 586 - } 587 - 588 - 589 - 590 - 591 - 592 - 593 - 594 -TTN V3 uplink screen shot. 595 - 596 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]] 597 - 598 -1. 599 -11. Configure RS485-BL via AT or Downlink 600 - 601 -User can configure RS485-BL via [[AT Commands >>path:#_Using_the_AT]]or LoRaWAN Downlink Commands 602 - 603 603 There are two kinds of Commands: 604 604 605 -* **Common Commands**: They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands499 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 606 606 607 -* **Sensor Related Commands**: These commands are special designed for RS485- BL. User can see these commands below:501 +* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-LN. User can see these commands below: 608 608 609 -1. 610 -11. 611 -111. Common Commands: 503 +=== 3.5.1 Common Commands === 612 612 613 -They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[ http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]]505 +They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 614 614 615 615 616 -1. 617 -11. 618 -111. Sensor related commands: 508 +=== 3.5.2 Sensor related commands === 619 619 620 - ==== ChooseDeviceType(RS485orTTL)====510 +Response feature is added to the server's downlink, a special package with a FPort of 200 will be uploaded immediately after receiving the data sent by the server. 621 621 622 - RS485-BL can connect to either RS485sensors or TTL sensor.Userneed to specify whattype of sensor needo connect.512 +[[image:image-20220602163333-5.png||height="263" width="1160"]] 623 623 624 - *ATCommand514 +The first byte of this package represents whether the configuration is successful, 00 represents failure, 01 represents success. Except for the first byte, the other is the previous downlink. (All commands except A8 type commands are applicable) 625 625 626 -**AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins. 627 627 628 - **AT+MOD=2** ~/~/Set to support TTL Level sensors,Usercan connectoneTTL Sensor to the TXD/RXD/GND pins.517 +3.5.3 Sensor related commands 629 629 519 +==== ==== 630 630 631 -* Downlink Payload 632 - 633 -**0A aa** à same as AT+MOD=aa 634 - 635 - 636 - 637 -==== [[RS485 Debug Command>>path:#downlink_A8]] (AT+CFGDEV) ==== 638 - 639 -This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling. 640 - 641 -* AT Command 642 - 643 -AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 644 - 645 -m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command. 646 - 647 - 648 - 649 -* Downlink Payload 650 - 651 -Format: A8 MM NN XX XX XX XX YY 652 - 653 -Where: 654 - 655 -* MM: 1: add CRC-16/MODBUS ; 0: no CRC 656 -* NN: The length of RS485 command 657 -* XX XX XX XX: RS485 command total NN bytes 658 -* YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command 659 - 660 -**Example 1:** 661 - 662 -To connect a Modbus Alarm with below commands. 663 - 664 -* The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 665 - 666 -* The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 667 - 668 -So if user want to use downlink command to control to RS485 Alarm, he can use: 669 - 670 -**A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm 671 - 672 -**A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm 673 - 674 -A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 675 - 676 - 677 -**Example 2:** 678 - 679 -Check TTL Sensor return: 680 - 681 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]] 682 - 683 - 684 - 685 - 686 -==== Set Payload version ==== 687 - 688 -This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. 689 - 690 -* AT Command: 691 - 692 -AT+PAYVER: Set PAYVER field = 1 693 - 694 - 695 -* Downlink Payload: 696 - 697 -0xAE 01 à Set PAYVER field = 0x01 698 - 699 -0xAE 0F à Set PAYVER field = 0x0F 700 - 701 - 702 -==== Set RS485 Sampling Commands ==== 703 - 704 -AT+COMMANDx, AT+DATACUTx and AT+SEARCHx 705 - 706 -These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#polling_485]]. 707 - 708 - 709 -* AT Command: 710 - 711 -AT+COMMANDx: Configure RS485 read command to sensor. 712 - 713 -AT+DATACUTx: Configure how to handle return from RS485 devices. 714 - 715 -AT+SEARCHx: Configure search command 716 - 717 - 718 -* Downlink Payload: 719 - 720 -0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 721 - 722 -Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 723 - 724 -Format: AF MM NN LL XX XX XX XX YY 725 - 726 -Where: 727 - 728 -* MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 729 -* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 730 -* LL: The length of AT+COMMAND or AT+DATACUT command 731 -* XX XX XX XX: AT+COMMAND or AT+DATACUT command 732 -* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command. 733 - 734 -Example: 735 - 736 -**AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1 737 - 738 -**AF 03 02 06 10 01 05 06 09 0A 00**: Same as AT+DATACUT3=**16**,**1**,**5+6+9+10** 739 - 740 -**AF 03 02 06 0B 02 05 07 08 0A 00**: Same as AT+DATACUT3=**11**,**2**,**5~~7+8~~10** 741 - 742 - 743 -0xAB downlink command can be used for set AT+SEARCHx 744 - 745 -Example: **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So 746 - 747 -* AB aa 01 03 xx xx xx same as AT+SEARCHaa=1,xx xx xx 748 -* AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands 749 - 750 -**AB aa 02 03 xx xx xx 02 yy yy** same as **AT+SEARCHaa=2,xx xx xx+yy yy** 751 - 752 - 753 -==== Fast command to handle MODBUS device ==== 754 - 755 -AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 756 - 757 -This command is valid since v1.3 firmware version 758 - 759 - 760 -AT+MBFUN has only two value: 761 - 762 -* AT+MBFUN=1: Enable Modbus reading. And get response base on the MODBUS return 763 - 764 -AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 765 - 766 -* AT+MBFUN=0: Disable Modbus fast reading. 767 - 768 -Example: 769 - 770 -* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). 771 -* AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 772 -* AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 773 - 774 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]] 775 - 776 - 777 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]] 778 - 779 - 780 -* Downlink Commands: 781 - 782 -A9 aa -à Same as AT+MBFUN=aa 783 - 784 - 785 -==== RS485 command timeout ==== 786 - 787 -Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. 788 - 789 -Default value: 0, range: 0 ~~ 5 seconds 790 - 791 - 792 -* AT Command: 793 - 794 -AT+CMDDLaa=hex(bb cc) 795 - 796 -Example: 797 - 798 -**AT+CMDDL1=1000** to send the open time to 1000ms 799 - 800 - 801 -* Downlink Payload: 802 - 803 -0x AA aa bb cc 804 - 805 -Same as: AT+CMDDLaa=hex(bb cc) 806 - 807 - Example: 808 - 809 - 0xAA 01 03 E8 à Same as **AT+CMDDL1=1000 ms** 810 - 811 - 812 -==== [[Uplink>>path:#downlink_A8]] payload mode ==== 813 - 814 -Define to use one uplink or multiple uplinks for the sampling. 815 - 816 -The use of this command please see: [[Compose Uplink payload>>path:#DataUP]] 817 - 818 -* AT Command: 819 - 820 -AT+DATAUP=0 821 - 822 -AT+DATAUP=1 823 - 824 - 825 -* Downlink Payload: 826 - 827 -0xAD 00 à Same as AT+DATAUP=0 828 - 829 -0xAD 01 à Same as AT+DATAUP=1 830 - 831 - 832 -==== Manually trigger an Uplink ==== 833 - 834 -Ask device to send an uplink immediately. 835 - 836 -* Downlink Payload: 837 - 838 -0x08 FF, RS485-BL will immediately send an uplink. 839 - 840 - 841 -==== Clear RS485 Command ==== 842 - 843 -The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 844 - 845 - 846 -* AT Command: 847 - 848 -**AT+CMDEAR=mm,nn** mm: start position of erase ,nn: stop position of erase 849 - 850 -Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 851 - 852 -Example screen shot after clear all RS485 commands. 853 - 854 - 855 - 856 -The uplink screen shot is: 857 - 858 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]] 859 - 860 - 861 -* Downlink Payload: 862 - 863 -0x09 aa bb same as AT+CMDEAR=aa,bb 864 - 865 - 866 -==== Set Serial Communication Parameters ==== 867 - 868 -Set the Rs485 serial communication parameters: 869 - 870 -* AT Command: 871 - 872 -Set Baud Rate: 873 - 874 -AT+BAUDR=9600 ~/~/ Options: (1200,2400,4800,14400,19200,115200) 875 - 876 - 877 -Set UART parity 878 - 879 -AT+PARITY=0 ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 880 - 881 - 882 -Set STOPBIT 883 - 884 -AT+STOPBIT=0 ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 885 - 886 - 887 -* Downlink Payload: 888 - 889 -A7 01 aa bb: Same AT+BAUDR=hex(aa bb)*100 890 - 891 -Example: 892 - 893 -* A7 01 00 60 same as AT+BAUDR=9600 894 -* A7 01 04 80 same as AT+BAUDR=115200 895 - 896 -A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 897 - 898 -A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 899 - 900 - 901 -==== Control output power duration ==== 902 - 903 -User can set the output power duration before each sampling. 904 - 905 -* AT Command: 906 - 907 -Example: 908 - 909 -AT+3V3T=1000 ~/~/ 3V3 output power will open 1s before each sampling. 910 - 911 -AT+5VT=1000 ~/~/ +5V output power will open 1s before each sampling. 912 - 913 - 914 -* LoRaWAN Downlink Command: 915 - 916 -07 01 aa bb Same as AT+5VT=(aa bb) 917 - 918 -07 02 aa bb Same as AT+3V3T=(aa bb) 919 - 920 - 921 - 922 - 923 -1. 924 -11. Buttons 925 - 926 -|**Button**|**Feature** 927 -|**RST**|Reboot RS485-BL 928 - 929 -1. 930 -11. +3V3 Output 931 - 932 -RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. 933 - 934 -The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 935 - 936 - 937 -The +3V3 output time can be controlled by AT Command. 938 - 939 -**AT+3V3T=1000** 940 - 941 -Means set +3v3 valid time to have 1000ms. So, the real +3v3 output will actually have 1000ms + sampling time for other sensors. 942 - 943 - 944 -By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 945 - 946 - 947 -1. 948 -11. +5V Output 949 - 950 -RS485-BL has a Controllable +5V output, user can use this output to power external sensor. 951 - 952 -The +5V output will be valid for every sampling. RS485-BL will enable +5V output before all sampling and disable the +5v after all sampling. 953 - 954 - 955 -The 5V output time can be controlled by AT Command. 956 - 957 -**AT+5VT=1000** 958 - 959 -Means set 5V valid time to have 1000ms. So, the real 5V output will actually have 1000ms + sampling time for other sensors. 960 - 961 - 962 -By default, the AT+5VT=0. If the external sensor which require 5v and require more time to get stable state, user can use this command to increase the power ON duration for this sensor. 963 - 964 - 965 - 966 - 967 -1. 968 -11. LEDs 969 - 970 -|**LEDs**|**Feature** 971 -|**LED1**|Blink when device transmit a packet. 972 - 973 -1. 974 -11. Switch Jumper 975 - 976 -|**Switch Jumper**|**Feature** 977 -|**SW1**|((( 978 -ISP position: Upgrade firmware via UART 979 - 980 -Flash position: Configure device, check running status. 981 -))) 982 -|**SW2**|((( 983 -5V position: set to compatible with 5v I/O. 984 - 985 -3.3v position: set to compatible with 3.3v I/O., 986 -))) 987 - 988 -+3.3V: is always ON 989 - 990 -+5V: Only open before every sampling. The time is by default, it is AT+5VT=0. Max open time. 5000 ms. 991 - 992 -1. Case Study 993 - 994 -User can check this URL for some case studies. 995 - 996 -[[http:~~/~~/wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS>>url:http://wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS]] 997 - 998 - 999 - 1000 - 1001 -1. Use AT Command 1002 -11. Access AT Command 1003 - 1004 -RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1005 - 1006 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]] 1007 - 1008 - 1009 -In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1010 - 1011 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]] 1012 - 1013 - 1014 - 1015 -More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]] 1016 - 1017 - 1018 - 1019 -1. 1020 -11. Common AT Command Sequence 1021 -111. Multi-channel ABP mode (Use with SX1301/LG308) 1022 - 1023 -If device has not joined network yet: 1024 - 1025 -AT+FDR 1026 - 1027 -AT+NJM=0 1028 - 1029 -ATZ 1030 - 1031 - 1032 -If device already joined network: 1033 - 1034 -AT+NJM=0 1035 - 1036 -ATZ 1037 - 1038 -1. 1039 -11. 1040 -111. Single-channel ABP mode (Use with LG01/LG02) 1041 - 1042 -AT+FDR Reset Parameters to Factory Default, Keys Reserve 1043 - 1044 -AT+NJM=0 Set to ABP mode 1045 - 1046 -AT+ADR=0 Set the Adaptive Data Rate Off 1047 - 1048 -AT+DR=5 Set Data Rate 1049 - 1050 -AT+TDC=60000 Set transmit interval to 60 seconds 1051 - 1052 -AT+CHS=868400000 Set transmit frequency to 868.4Mhz 1053 - 1054 -AT+RX2FQ=868400000 Set RX2Frequency to 868.4Mhz (according to the result from server) 1055 - 1056 -AT+RX2DR=5 Set RX2DR to match the downlink DR from server. see below 1057 - 1058 -AT+DADDR=26 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1059 - 1060 -ATZ Reset MCU 1061 - 1062 -**Note:** 1063 - 1064 -1. Make sure the device is set to ABP mode in the IoT Server. 1065 -1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1066 -1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1067 -1. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1068 - 1069 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image029.png]] 1070 - 1071 - 1072 -1. FAQ 1073 -11. How to upgrade the image? 1074 - 1075 -The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to: 1076 - 1077 -* Support new features 1078 -* For bug fix 1079 -* Change LoRaWAN bands. 1080 - 1081 -Below shows the hardware connection for how to upload an image to RS485-BL: 1082 - 1083 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image030.png]] 1084 - 1085 -**Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1086 - 1087 -**Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 1088 - 1089 -**Step3: **Open flashloader; choose the correct COM port to update. 1090 - 1091 - 1092 -|((( 1093 -HOLD PRO then press the RST button, SYS will be ON, then click next 1094 -))) 1095 - 1096 -|((( 1097 -Board detected 1098 -))) 1099 - 1100 -|((( 1101 - 1102 -))) 1103 - 1104 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image031.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image032.png]] 1105 - 1106 - 1107 - 1108 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image033.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image034.png]] 1109 - 1110 - 1111 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1112 - 1113 - 1114 -1. 1115 -11. How to change the LoRa Frequency Bands/Region? 1116 - 1117 -User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. 1118 - 1119 - 1120 - 1121 -1. 1122 -11. How many RS485-Slave can RS485-BL connects? 1123 - 1124 -The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. 1125 - 1126 - 1127 - 1128 - 1129 -1. Trouble Shooting 1130 -11. Downlink doesn’t work, how to solve it? 1131 - 1132 -Please see this link for debug: 1133 - 1134 -[[http:~~/~~/wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug>>url:http://wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug]] 1135 - 1136 - 1137 - 1138 -1. 1139 -11. Why I can’t join TTN V3 in US915 /AU915 bands? 1140 - 1141 -It might about the channels mapping. Please see for detail. 1142 - 1143 -[[http:~~/~~/wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band>>url:http://wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band]] 1144 - 1145 - 1146 - 1147 -1. Order Info 1148 - 1149 -**Part Number: RS485-BL-XXX** 1150 - 1151 -**XXX:** 1152 - 1153 -* **EU433**: frequency bands EU433 1154 -* **EU868**: frequency bands EU868 1155 -* **KR920**: frequency bands KR920 1156 -* **CN470**: frequency bands CN470 1157 -* **AS923**: frequency bands AS923 1158 -* **AU915**: frequency bands AU915 1159 -* **US915**: frequency bands US915 1160 -* **IN865**: frequency bands IN865 1161 -* **RU864**: frequency bands RU864 1162 -* **KZ865: **frequency bands KZ865 1163 - 1164 -1. Packing Info 1165 - 1166 -**Package Includes**: 1167 - 1168 -* RS485-BL x 1 1169 -* Stick Antenna for LoRa RF part x 1 1170 -* Program cable x 1 1171 - 1172 -**Dimension and weight**: 1173 - 1174 -* Device Size: 13.5 x 7 x 3 cm 1175 -* Device Weight: 105g 1176 -* Package Size / pcs : 14.5 x 8 x 5 cm 1177 -* Weight / pcs : 170g 1178 - 1179 -1. Support 1180 - 1181 -* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1182 -* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to 1183 - 1184 -[[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 521 +==== ====
- 1654157178836-407.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +179.9 KB - Content
- 1654157342174-798.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +31.9 KB - Content
- 1654158783574-851.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.6 KB - Content
- image-20220602153621-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.4 KB - Content
- image-20220602153621-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.2 KB - Content
- image-20220602153621-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +22.3 KB - Content
- image-20220602155039-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.6 KB - Content
- image-20220602163333-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +48.2 KB - Content