Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Xiaoling on 2025/04/23 15:56
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 15 removed)
- 1652953414711-647.png
- 1652953462722-299.png
- 1652953542269-423.png
- 1652953553383-907.png
- 1652953568895-172.png
- 1652954654347-831.png
- 1653266934636-343.png
- 1653267211009-519.png
- 1653268091319-405.png
- 1653268155545-638.png
- 1653268227651-549.png
- image-20220519174512-1.png
- image-20220519174512-2.png
- image-20220519174512-3.png
- image-20220519174512-4.png
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -RS485-L N– RS485 to LoRaWAN Converter1 +RS485-BL – Waterproof RS485 to LoRaWAN Converter - Content
-
... ... @@ -1,11 +1,13 @@ 1 1 (% style="text-align:center" %) 2 -[[image:165 3266934636-343.png||height="385" width="385"]]2 +[[image:1652947681187-144.png||height="385" width="385"]] 3 3 4 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.jpg]] 4 4 5 5 6 -**RS485-LN – RS485 to LoRaWAN Converter User Manual** 7 7 8 +**RS485-BL – Waterproof RS485 to LoRaWAN Converter User Manual** 8 8 10 + 9 9 **Table of Contents:** 10 10 11 11 ... ... @@ -14,44 +14,62 @@ 14 14 15 15 = 1.Introduction = 16 16 17 -== 1.1 What is RS485-L NRS485 to LoRaWAN Converter ==19 +== 1.1 What is RS485-BL RS485 to LoRaWAN Converter == 18 18 19 19 ((( 22 + 23 +))) 24 + 20 20 ((( 21 -The Dragino RS485-L Nis a RS485 to LoRaWAN Converter.It converts the RS485 signalintoLoRaWANwirelesssignalwhich simplify theIoTinstallationandreducetheinstallation/maintainingcost.26 +The Dragino RS485-BL is a **RS485 / UART to LoRaWAN Converter** for Internet of Things solutions. User can connect RS485 or UART sensor to RS485-BL converter, and configure RS485-BL to periodically read sensor data and upload via LoRaWAN network to IoT server. 22 22 ))) 23 23 24 24 ((( 25 -RS485-L Nallows user to monitor/controlRS485devicesandreachextremelylongranges.Itprovidesultra-longrangespreadspectrumcommunicationand high interference immunity whilstminimizing currentconsumption.Ittargetsprofessional wirelesssensornetwork applicationssuch asirrigationsystems,smartmetering, smartcities,smartphonedetection, building automation, and so on.30 +RS485-BL can interface to RS485 sensor, 3.3v/5v UART sensor or interrupt sensor. RS485-BL provides **a 3.3v output** and** a 5v output** to power external sensors. Both output voltages are controllable to minimize the total system power consumption. 26 26 ))) 27 27 28 28 ((( 29 - For data uplink,RS485-LNsendsuser-definedcommandstoRS485devicesand getstheeturnfromtheRS485devices. RS485-LN will processthesereturnsaccording to user-definerulestoget thefinalpayload and upload to LoRaWAN server.34 +RS485-BL is IP67 **waterproof** and powered by **8500mAh Li-SOCI2 battery**, it is designed for long term use for several years. 30 30 ))) 31 31 32 32 ((( 33 - For data downlink,RS485-LNrunsin LoRaWAN ClassC.WhentheredownlinkcommandsfromLoRaWANserver, RS485-LN willforwardthecommandsfromLoRaWANserverto RS485 devices.38 +RS485-BL runs standard **LoRaWAN 1.0.3 in Class A**. It can reach long transfer range and easy to integrate with LoRaWAN compatible gateway and IoT server. 34 34 ))) 40 + 41 +((( 42 +For data uplink, RS485-BL sends user-defined commands to RS485 devices and gets the return from the RS485 devices. RS485-BL will process these returns data according to user-define rules to get the final payload and upload to LoRaWAN server. 35 35 ))) 36 36 37 -[[image:1653267211009-519.png||height="419" width="724"]] 45 +((( 46 +For data downlink, RS485-BL runs in LoRaWAN Class A. When there is downlink commands from LoRaWAN server, RS485-BL will forward the commands from LoRaWAN server to RS485 devices. 47 +))) 38 38 49 +((( 50 +Each RS485-BL pre-load with a set of unique keys for LoRaWAN registration, register these keys to LoRaWAN server and it will auto connect after power on. 51 +))) 52 + 53 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image002.png]] 54 + 39 39 == 1.2 Specifications == 40 40 41 41 **Hardware System:** 42 42 43 43 * STM32L072CZT6 MCU 44 -* SX1276/78 Wireless Chip 60 +* SX1276/78 Wireless Chip 45 45 * Power Consumption (exclude RS485 device): 46 -** Idle: 32mA@12v62 +** Idle: 6uA@3.3v 47 47 48 -* 49 -** 20dB Transmit: 65mA@12v64 +* 65 +** 20dB Transmit: 130mA@3.3v 50 50 51 51 **Interface for Model:** 52 52 53 -* RS485 54 -* Power Input 7~~ 24V DC. 69 +* 1 x RS485 Interface 70 +* 1 x TTL Serial , 3.3v or 5v. 71 +* 1 x I2C Interface, 3.3v or 5v. 72 +* 1 x one wire interface 73 +* 1 x Interrupt Interface 74 +* 1 x Controllable 5V output, max 55 55 56 56 **LoRa Spec:** 57 57 ... ... @@ -60,30 +60,27 @@ 60 60 ** Band 2 (LF): 410 ~~ 528 Mhz 61 61 * 168 dB maximum link budget. 62 62 * +20 dBm - 100 mW constant RF output vs. 63 -* +14 dBm high efficiency PA. 64 64 * Programmable bit rate up to 300 kbps. 65 65 * High sensitivity: down to -148 dBm. 66 66 * Bullet-proof front end: IIP3 = -12.5 dBm. 67 67 * Excellent blocking immunity. 68 -* Low RX current of 10.3 mA, 200 nA register retention. 69 69 * Fully integrated synthesizer with a resolution of 61 Hz. 70 -* FSK, GFSK, MSK, GMSK,LoRaTMand OOKmodulation.88 +* LoRa modulation. 71 71 * Built-in bit synchronizer for clock recovery. 72 72 * Preamble detection. 73 73 * 127 dB Dynamic Range RSSI. 74 -* Automatic RF Sense and CAD with ultra-fast AFC. 75 -* Packet engine up to 256 bytes with CRC. 92 +* Automatic RF Sense and CAD with ultra-fast AFC. 76 76 77 77 == 1.3 Features == 78 78 79 -* LoRaWAN Class A & Class C protocol (default Class C)96 +* LoRaWAN Class A & Class C protocol (default Class A) 80 80 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865/RU864 81 81 * AT Commands to change parameters 82 -* Remote configure parameters via LoRa Downlink 99 +* Remote configure parameters via LoRaWAN Downlink 83 83 * Firmware upgradable via program port 84 84 * Support multiply RS485 devices by flexible rules 85 85 * Support Modbus protocol 86 -* Support Interrupt uplink (Since hardware version v1.2)103 +* Support Interrupt uplink 87 87 88 88 == 1.4 Applications == 89 89 ... ... @@ -94,269 +94,262 @@ 94 94 * Smart Cities 95 95 * Smart Factory 96 96 97 -== 1.5 Firmware Change log == 114 +== 1.5 Firmware Change log == 98 98 99 -[[RS485-L NImage files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]116 +[[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]] 100 100 101 101 == 1.6 Hardware Change log == 102 102 103 103 ((( 104 -((( 105 -v1.2: Add External Interrupt Pin. 106 - 107 -v1.0: Release 121 +v1.4 108 108 ))) 109 -))) 110 110 111 -= 2. Power ON Device = 112 - 113 113 ((( 114 -The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below 125 +~1. Change Power IC to TPS22916 126 +))) 115 115 116 -* Power Source VIN to RS485-LN VIN+ 117 -* Power Source GND to RS485-LN VIN- 118 118 119 119 ((( 120 - Once there is power, the RS485-LN will be on.130 +v1.3 121 121 ))) 122 122 123 -[[image:1653268091319-405.png]] 133 +((( 134 +~1. Change JP3 from KF350-8P to KF350-11P, Add one extra interface for I2C and one extra interface for one-wire 124 124 ))) 125 125 126 -= 3. Operation Mode = 127 127 128 -== 3.1 How it works? == 138 +((( 139 +v1.2 140 +))) 129 129 130 130 ((( 131 - TheRS485-LN is configured as LoRaWAN OTAA Class C modeby default. It hasOTAA keysto join network. To connect a local LoRaWAN network, user just need toinput the OTAA keys in the network server andpower on the RS485-LN. It will auto join the network via OTAA.143 +Release version 132 132 ))) 133 133 134 -= =3.2Example to joinLoRaWANnetwork==146 += 2. Pin mapping and Power ON Device = 135 135 136 - Hereshows anexampleforhowto jointhe TTNV3 Network.Belowisthenetworkstructure,we use[[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] asLoRaWAN gateway here.148 +The RS485-BL is powered on by 8500mAh battery. To save battery life, RS485-BL is shipped with power off. User can put the jumper to power on RS485-BL. 137 137 138 -[[image:165 3268155545-638.png||height="334" width="724"]]150 +[[image:1652953055962-143.png||height="387" width="728"]] 139 139 140 -((( 141 -The RS485-LN in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method. The connection is as below: 152 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image003.png]] 142 142 143 - 485A+and485B-of the sensorare connectedtoRS485Aand RA485B of RS485-LN respectively.154 +The Left TXD and RXD are TTL interface for external sensor. TTL level is controlled by 3.3/5v Jumper. 144 144 145 -[[image:1653268227651-549.png||height="592" width="720"]] 146 146 147 -((( 148 -The LG308 is already set to connect to [[TTN V3 network >>path:eu1.cloud.thethings.network/]]. So what we need to now is only configure the TTN V3: 149 -))) 150 150 151 -((( 152 -**Step 1**: Create a device in TTN V3 with the OTAA keys from RS485-LN. 153 -))) 158 +3. Operation Mode 159 +3.1 How it works? 154 154 155 -((( 156 -Each RS485-LN is shipped with a sticker with unique device EUI: 157 -))) 158 -))) 161 +The RS485-BL is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-BL. It will auto join the network via OTAA. 159 159 160 -[[image:1652953462722-299.png]] 161 161 162 -((( 163 -((( 164 +1. 165 +11. Example to join LoRaWAN network 166 + 167 +Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 168 + 169 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image004.png]] 170 + 171 + 172 +The RS485-BL in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method. 173 + 174 + 175 +The LG308 is already set to connect to [[TTN V3 network >>url:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3: 176 + 177 +**Step 1**: Create a device in TTN V3 with the OTAA keys from RS485-BL. 178 + 179 +Each RS485-BL is shipped with a sticker with unique device EUI: 180 + 181 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image005.png]] 182 + 183 + 184 + 185 + 164 164 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot: 165 -))) 166 166 167 -((( 168 168 Add APP EUI in the application. 169 -))) 170 -))) 171 171 172 -[[image:i mage-20220519174512-1.png]]190 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image006.png]] 173 173 174 -[[image:image -20220519174512-2.png||height="323" width="720"]]192 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image007.png]] 175 175 176 -[[image:image -20220519174512-3.png||height="556" width="724"]]194 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image008.png]] 177 177 178 -[[image:image -20220519174512-4.png]]196 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image009.png]] 179 179 180 -You can also choose to create the device manually. 181 181 182 -[[image:1652953542269-423.png||height="710" width="723"]] 183 183 184 -Add APP KEY and DEV EUI 185 185 186 -[[image:1652953553383-907.png||height="514" width="724"]] 187 187 188 188 189 -((( 190 -**Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 191 -))) 192 192 193 -[[image:1652953568895-172.png||height="232" width="724"]] 194 194 195 -== 3.3 Configure Commands to read data == 196 196 197 -((( 198 -((( 199 -There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#AT_COMMAND]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 200 -))) 201 201 202 -((( 203 -(% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1 204 -))) 205 -))) 206 206 207 -=== 3.3.1 onfigure UART settings for RS485 or TTL communication === 208 208 209 -To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are: 210 210 211 -(% border="1" style="background-color:#ffffcc; color:green; width:795px" %) 210 + 211 + 212 + 213 + 214 +You can also choose to create the device manually. 215 + 212 212 |((( 213 -**AT Commands** 214 -)))|(% style="width:285px" %)((( 215 -**Description** 216 -)))|(% style="width:347px" %)((( 217 -**Example** 217 + 218 218 ))) 219 -|((( 220 -AT+BAUDR 221 -)))|(% style="width:285px" %)((( 222 -Set the baud rate (for RS485 connection). Default Value is: 9600. 223 -)))|(% style="width:347px" %)((( 224 -((( 219 + 220 + 221 + 222 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image010.png]] 223 + 224 +Add APP KEY and DEV EUI 225 + 226 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image011.png]] 227 + 228 + 229 +**Step 2**: Power on RS485-BL and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 230 + 231 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image012.png]] 232 + 233 + 234 + 235 + 236 +1. 237 +11. Configure Commands to read data 238 + 239 +There are plenty of RS485 and TTL level devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-BL supports flexible command set. User can use [[AT Commands or LoRaWAN Downlink>>path:#AT_COMMAND]] Command to configure how RS485-BL should read the sensor and how to handle the return from RS485 or TTL sensors. 240 + 241 + 242 +1. 243 +11. 244 +111. Configure UART settings for RS485 or TTL communication 245 + 246 +RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect. 247 + 248 +1. RS485-MODBUS mode: 249 + 250 +AT+MOD=1 ~/~/ Support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins. 251 + 252 + 253 +1. TTL mode: 254 + 255 +AT+MOD=2 ~/~/ Support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins. 256 + 257 + 258 +RS485-BL default UART settings is **9600, no parity, stop bit 1**. If the sensor has a different settings, user can change the RS485-BL setting to match. 259 + 260 + 261 +|**AT Commands**|**Description**|**Example** 262 +|AT+BAUDR|Set the baud rate (for RS485 connection). Default Value is: 9600.|((( 225 225 AT+BAUDR=9600 226 -))) 227 227 228 -((( 229 229 Options: (1200,2400,4800,14400,19200,115200) 230 230 ))) 231 -))) 232 -|((( 233 -AT+PARITY 234 -)))|(% style="width:285px" %)((( 267 +|AT+PARITY|((( 235 235 Set UART parity (for RS485 connection) 236 -)))|(% style="width:347px" %)((( 237 -((( 269 + 270 +Default Value is: no parity. 271 +)))|((( 238 238 AT+PARITY=0 239 -))) 240 240 241 -((( 242 242 Option: 0: no parity, 1: odd parity, 2: even parity 243 243 ))) 244 -))) 245 -|((( 246 -AT+STOPBIT 247 -)))|(% style="width:285px" %)((( 248 -((( 276 +|AT+STOPBIT|((( 249 249 Set serial stopbit (for RS485 connection) 250 -))) 251 251 252 -((( 253 - 254 -))) 255 -)))|(% style="width:347px" %)((( 256 -((( 279 +Default Value is: 1bit. 280 +)))|((( 257 257 AT+STOPBIT=0 for 1bit 258 -))) 259 259 260 -((( 261 261 AT+STOPBIT=1 for 1.5 bit 262 -))) 263 263 264 -((( 265 265 AT+STOPBIT=2 for 2 bits 266 266 ))) 267 -))) 268 268 269 -=== 3.3.2 Configure sensors === 270 270 271 -((( 272 -((( 273 -Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won’t run during each sampling. 274 -))) 275 -))) 276 276 277 -(% border="1" style="background-color:#ffffcc; color:green; width:806px" %) 278 -|**AT Commands**|(% style="width:418px" %)**Description**|(% style="width:256px" %)**Example** 279 -|AT+CFGDEV|(% style="width:418px" %)((( 290 + 291 + 292 +1. 293 +11. 294 +111. Configure sensors 295 + 296 +Some sensors might need to configure before normal operation. User can configure such sensor via PC or through RS485-BL AT Commands AT+CFGDEV. 297 + 298 + 299 +When user issue an AT+CFGDEV command, Each AT+CFGDEV equals to send a command to the RS485 or TTL sensors. This command will only run when user input it and won’t run during each sampling. 300 + 301 +|**AT Commands**|**Description**|**Example** 302 +|AT+CFGDEV|((( 280 280 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 281 281 282 -AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 305 +AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 283 283 284 -m m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command285 -)))| (% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m307 +m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 308 +)))|AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 286 286 287 - ===3.3.3 Configurereadcommandsforeach sampling ===310 +Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>path:#AT_CFGDEV]]. 288 288 289 -((( 312 + 313 + 314 + 315 + 316 +1. 317 +11. 318 +111. Configure read commands for each sampling 319 + 290 290 RS485-BL is a battery powered device; it will sleep most of time. And wake up on each period and read RS485 / TTL sensor data and uplink. 291 -))) 292 292 293 - (((322 + 294 294 During each sampling, we need to confirm what commands we need to send to the sensors to read data. After the RS485/TTL sensors send back the value, it normally includes some bytes and we only need a few from them for a shorten payload. 295 -))) 296 296 297 - (((325 + 298 298 To save the LoRaWAN network bandwidth, we might need to read data from different sensors and combine their valid value into a short payload. 299 -))) 300 300 301 - (((328 + 302 302 This section describes how to achieve above goals. 303 -))) 304 304 305 - (((331 + 306 306 During each sampling, the RS485-BL can support 15 commands to read sensors. And combine the return to one or several uplink payloads. 307 -))) 308 308 309 - (((334 + 310 310 **Command from RS485-BL to Sensor:** 311 -))) 312 312 313 -((( 314 314 RS485-BL can send out pre-set max 15 strings via **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF** . All commands are of same grammar. 315 -))) 316 316 317 - (((339 + 318 318 **Handle return from sensors to RS485-BL**: 319 -))) 320 320 321 -((( 322 322 After RS485-BL send out a string to sensor, RS485-BL will wait for the return from RS485 or TTL sensor. And user can specify how to handle the return, by **AT+DATACUT or AT+SEARCH commands** 323 -))) 324 324 325 -* ((( 326 -**AT+DATACUT** 327 -))) 328 328 329 -((( 345 +* **AT+DATACUT** 346 + 330 330 When the return value from sensor have fix length and we know which position the valid value we should get, we can use AT+DATACUT command. 331 -))) 332 332 333 -* ((( 334 -**AT+SEARCH** 335 -))) 336 336 337 -((( 350 +* **AT+SEARCH** 351 + 338 338 When the return value from sensor is dynamic length and we are not sure which bytes the valid data is, instead, we know what value the valid value following. We can use AT+SEARCH to search the valid value in the return string. 339 -))) 340 340 341 - (((354 + 342 342 **Define wait timeout:** 343 -))) 344 344 345 -((( 346 346 Some RS485 device might has longer delay on reply, so user can use AT+CMDDL to set the timeout for getting reply after the RS485 command is sent. For example, AT+CMDDL1=1000 to send the open time to 1000ms 347 -))) 348 348 349 - (((359 + 350 350 After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**. 351 -))) 352 352 362 + 353 353 **Examples:** 354 354 355 355 Below are examples for the how above AT Commands works. 356 356 367 + 357 357 **AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is: 358 358 359 -(% border="1" class="table-bordered" %) 360 360 |((( 361 361 **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m** 362 362 ... ... @@ -369,9 +369,9 @@ 369 369 370 370 In the RS485-BL, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same. 371 371 382 + 372 372 **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx. 373 373 374 -(% border="1" class="table-bordered" %) 375 375 |((( 376 376 **AT+SEARCHx=aa,xx xx xx xx xx** 377 377 ... ... @@ -389,7 +389,7 @@ 389 389 390 390 The valid data will be all bytes after 1E 56 34 , so it is 2e 30 58 5f 36 41 30 31 00 49 391 391 392 -[[image: 1652954654347-831.png]]402 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image013.png]] 393 393 394 394 395 395 1. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 ... ... @@ -408,7 +408,7 @@ 408 408 409 409 * **a: length for the return of AT+COMMAND** 410 410 * **b:1: grab valid value by byte, max 6 bytes. 2: grab valid value by bytes section, max 3 sections.** 411 -* **c: define the position for valid value. 421 +* **c: define the position for valid value. ** 412 412 ))) 413 413 414 414 Examples: ... ... @@ -449,8 +449,8 @@ 449 449 450 450 451 451 452 -1. 453 -11. 462 +1. 463 +11. 454 454 111. Compose the uplink payload 455 455 456 456 Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.** ... ... @@ -514,8 +514,8 @@ 514 514 515 515 516 516 517 -1. 518 -11. 527 +1. 528 +11. 519 519 111. Uplink on demand 520 520 521 521 Except uplink periodically, RS485-BL is able to uplink on demand. The server sends downlink command to RS485-BL and RS485 will uplink data base on the command. ... ... @@ -528,8 +528,8 @@ 528 528 529 529 530 530 531 -1. 532 -11. 541 +1. 542 +11. 533 533 111. Uplink on Interrupt 534 534 535 535 Put the interrupt sensor between 3.3v_out and GPIO ext.[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]] ... ... @@ -543,9 +543,10 @@ 543 543 AT+INTMOD=3 Interrupt trigger by rising edge. 544 544 545 545 546 -1. 556 +1. 547 547 11. Uplink Payload 548 548 559 + 549 549 |**Size(bytes)**|**2**|**1**|**Length depends on the return from the commands** 550 550 |Value|((( 551 551 Battery(mV) ... ... @@ -594,7 +594,7 @@ 594 594 595 595 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]] 596 596 597 -1. 608 +1. 598 598 11. Configure RS485-BL via AT or Downlink 599 599 600 600 User can configure RS485-BL via [[AT Commands >>path:#_Using_the_AT]]or LoRaWAN Downlink Commands ... ... @@ -605,17 +605,20 @@ 605 605 606 606 * **Sensor Related Commands**: These commands are special designed for RS485-BL. User can see these commands below: 607 607 608 -1. 609 -11. 619 + 620 +1. 621 +11. 610 610 111. Common Commands: 611 611 624 + 612 612 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]] 613 613 614 614 615 -1. 616 -11. 628 +1. 629 +11. 617 617 111. Sensor related commands: 618 618 632 + 619 619 ==== Choose Device Type (RS485 or TTL) ==== 620 620 621 621 RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect. ... ... @@ -656,6 +656,7 @@ 656 656 * XX XX XX XX: RS485 command total NN bytes 657 657 * YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command 658 658 673 + 659 659 **Example 1:** 660 660 661 661 To connect a Modbus Alarm with below commands. ... ... @@ -764,6 +764,7 @@ 764 764 765 765 * AT+MBFUN=0: Disable Modbus fast reading. 766 766 782 + 767 767 Example: 768 768 769 769 * AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). ... ... @@ -848,7 +848,7 @@ 848 848 849 849 Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 850 850 851 -Example screen shot after clear all RS485 commands. 867 +Example screen shot after clear all RS485 commands. 852 852 853 853 854 854 ... ... @@ -892,6 +892,7 @@ 892 892 * A7 01 00 60 same as AT+BAUDR=9600 893 893 * A7 01 04 80 same as AT+BAUDR=115200 894 894 911 + 895 895 A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 896 896 897 897 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) ... ... @@ -919,18 +919,20 @@ 919 919 920 920 921 921 922 -1. 939 +1. 923 923 11. Buttons 924 924 942 + 925 925 |**Button**|**Feature** 926 926 |**RST**|Reboot RS485-BL 927 927 928 -1. 946 + 947 +1. 929 929 11. +3V3 Output 930 930 931 931 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. 932 932 933 -The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 952 +The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 934 934 935 935 936 936 The +3V3 output time can be controlled by AT Command. ... ... @@ -943,12 +943,12 @@ 943 943 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 944 944 945 945 946 -1. 965 +1. 947 947 11. +5V Output 948 948 949 949 RS485-BL has a Controllable +5V output, user can use this output to power external sensor. 950 950 951 -The +5V output will be valid for every sampling. RS485-BL will enable +5V output before all sampling and disable the +5v after all sampling. 970 +The +5V output will be valid for every sampling. RS485-BL will enable +5V output before all sampling and disable the +5v after all sampling. 952 952 953 953 954 954 The 5V output time can be controlled by AT Command. ... ... @@ -963,13 +963,14 @@ 963 963 964 964 965 965 966 -1. 985 +1. 967 967 11. LEDs 968 968 969 969 |**LEDs**|**Feature** 970 970 |**LED1**|Blink when device transmit a packet. 971 971 972 -1. 991 + 992 +1. 973 973 11. Switch Jumper 974 974 975 975 |**Switch Jumper**|**Feature** ... ... @@ -990,6 +990,7 @@ 990 990 991 991 1. Case Study 992 992 1013 + 993 993 User can check this URL for some case studies. 994 994 995 995 [[http:~~/~~/wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS>>url:http://wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS]] ... ... @@ -1015,7 +1015,7 @@ 1015 1015 1016 1016 1017 1017 1018 -1. 1039 +1. 1019 1019 11. Common AT Command Sequence 1020 1020 111. Multi-channel ABP mode (Use with SX1301/LG308) 1021 1021 ... ... @@ -1034,8 +1034,8 @@ 1034 1034 1035 1035 ATZ 1036 1036 1037 -1. 1038 -11. 1058 +1. 1059 +11. 1039 1039 111. Single-channel ABP mode (Use with LG01/LG02) 1040 1040 1041 1041 AT+FDR Reset Parameters to Factory Default, Keys Reserve ... ... @@ -1077,6 +1077,7 @@ 1077 1077 * For bug fix 1078 1078 * Change LoRaWAN bands. 1079 1079 1101 + 1080 1080 Below shows the hardware connection for how to upload an image to RS485-BL: 1081 1081 1082 1082 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image030.png]] ... ... @@ -1110,7 +1110,7 @@ 1110 1110 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1111 1111 1112 1112 1113 -1. 1135 +1. 1114 1114 11. How to change the LoRa Frequency Bands/Region? 1115 1115 1116 1116 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. ... ... @@ -1117,9 +1117,10 @@ 1117 1117 1118 1118 1119 1119 1120 -1. 1142 +1. 1121 1121 11. How many RS485-Slave can RS485-BL connects? 1122 1122 1145 + 1123 1123 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. 1124 1124 1125 1125 ... ... @@ -1130,11 +1130,11 @@ 1130 1130 1131 1131 Please see this link for debug: 1132 1132 1133 -[[http:~~/~~/wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug>>url:http://wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug]] 1156 +[[http:~~/~~/wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug>>url:http://wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug]] 1134 1134 1135 1135 1136 1136 1137 -1. 1160 +1. 1138 1138 11. Why I can’t join TTN V3 in US915 /AU915 bands? 1139 1139 1140 1140 It might about the channels mapping. Please see for detail. ... ... @@ -1145,6 +1145,7 @@ 1145 1145 1146 1146 1. Order Info 1147 1147 1171 + 1148 1148 **Part Number: RS485-BL-XXX** 1149 1149 1150 1150 **XXX:** ... ... @@ -1160,6 +1160,7 @@ 1160 1160 * **RU864**: frequency bands RU864 1161 1161 * **KZ865: **frequency bands KZ865 1162 1162 1187 + 1163 1163 1. Packing Info 1164 1164 1165 1165 **Package Includes**: ... ... @@ -1168,6 +1168,7 @@ 1168 1168 * Stick Antenna for LoRa RF part x 1 1169 1169 * Program cable x 1 1170 1170 1196 + 1171 1171 **Dimension and weight**: 1172 1172 1173 1173 * Device Size: 13.5 x 7 x 3 cm ... ... @@ -1175,6 +1175,7 @@ 1175 1175 * Package Size / pcs : 14.5 x 8 x 5 cm 1176 1176 * Weight / pcs : 170g 1177 1177 1204 + 1178 1178 1. Support 1179 1179 1180 1180 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
- 1652953414711-647.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -119.3 KB - Content
- 1652953462722-299.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -202.7 KB - Content
- 1652953542269-423.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -118.5 KB - Content
- 1652953553383-907.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -94.0 KB - Content
- 1652953568895-172.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -109.3 KB - Content
- 1652954654347-831.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -138.7 KB - Content
- 1653266934636-343.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -176.5 KB - Content
- 1653267211009-519.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -138.7 KB - Content
- 1653268091319-405.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -399.3 KB - Content
- 1653268155545-638.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -113.7 KB - Content
- 1653268227651-549.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -1.3 MB - Content
- image-20220519174512-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -32.2 KB - Content
- image-20220519174512-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -42.7 KB - Content
- image-20220519174512-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -36.3 KB - Content
- image-20220519174512-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.1 KB - Content