Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Karry Zhuang on 2025/03/06 16:34
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 12 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,12 +1,11 @@ 1 1 (% style="text-align:center" %) 2 -[[image:165294 7681187-144.png||height="385" width="385"]]2 +[[image:1653266934636-343.png||height="385" width="385"]] 3 3 4 4 5 5 6 +**RS485-LN – RS485 to LoRaWAN Converter User Manual** 6 6 7 -**RS485-BL – Waterproof RS485 to LoRaWAN Converter User Manual** 8 8 9 - 10 10 **Table of Contents:** 11 11 12 12 ... ... @@ -15,42 +15,28 @@ 15 15 16 16 = 1.Introduction = 17 17 18 -== 1.1 What is RS485- BL RS485 to LoRaWAN Converter ==17 +== 1.1 What is RS485-LN RS485 to LoRaWAN Converter == 19 19 20 20 ((( 21 - 22 -))) 23 - 24 24 ((( 25 -The Dragino RS485- BL is a**RS485/ UARTto LoRaWAN Converter**forInternetof Things solutions.Usercan connectRS485or UARTsensortoRS485-BLconverter,andconfigureRS485-BLtoperiodicallyreadsensor dataand upload via LoRaWANnetworktoIoTserver.21 +The Dragino RS485-LN is a RS485 to LoRaWAN Converter. It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost. 26 26 ))) 27 27 28 28 ((( 29 -RS485- BLcaninterfaceto RS485sensor,3.3v/5vUARTsensor orinterruptsensor.RS485-BLprovides**a 3.3v output**and**a5voutput** topowerexternal sensors.Bothoutputvoltages arecontrollabletominimizethe totalsystempowerconsumption.25 +RS485-LN allows user to monitor / control RS485 devices and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on. 30 30 ))) 31 31 32 32 ((( 33 -RS485- BLisIP67 **waterproof**andpoweredby **8500mAhLi-SOCI2battery**,itisdesignedforlong termuseforseveral years.29 +For data uplink, RS485-LN sends user-defined commands to RS485 devices and gets the return from the RS485 devices. RS485-LN will process these returns according to user-define rules to get the final payload and upload to LoRaWAN server. 34 34 ))) 35 35 36 36 ((( 37 -RS485- BL runsstandard**LoRaWAN1.0.3 inClassA**.It can reachlong transferrange andeasytointegrate withLoRaWANcompatiblegatewayandIoTserver.33 +For data downlink, RS485-LN runs in LoRaWAN Class C. When there downlink commands from LoRaWAN server, RS485-LN will forward the commands from LoRaWAN server to RS485 devices. 38 38 ))) 39 - 40 -((( 41 -For data uplink, RS485-BL sends user-defined commands to RS485 devices and gets the return from the RS485 devices. RS485-BL will process these returns data according to user-define rules to get the final payload and upload to LoRaWAN server. 42 42 ))) 43 43 44 -((( 45 -For data downlink, RS485-BL runs in LoRaWAN Class A. When there is downlink commands from LoRaWAN server, RS485-BL will forward the commands from LoRaWAN server to RS485 devices. 46 -))) 37 +[[image:1653267211009-519.png||height="419" width="724"]] 47 47 48 -((( 49 -Each RS485-BL pre-load with a set of unique keys for LoRaWAN registration, register these keys to LoRaWAN server and it will auto connect after power on. 50 -))) 51 - 52 -[[image:1652953304999-717.png||height="424" width="733"]] 53 - 54 54 == 1.2 Specifications == 55 55 56 56 **Hardware System:** ... ... @@ -58,19 +58,15 @@ 58 58 * STM32L072CZT6 MCU 59 59 * SX1276/78 Wireless Chip 60 60 * Power Consumption (exclude RS485 device): 61 -** Idle: 6uA@3.3v46 +** Idle: 32mA@12v 62 62 63 -* 64 -** 20dB Transmit: 130mA@3.3v48 +* 49 +** 20dB Transmit: 65mA@12v 65 65 66 66 **Interface for Model:** 67 67 68 -* 1 x RS485 Interface 69 -* 1 x TTL Serial , 3.3v or 5v. 70 -* 1 x I2C Interface, 3.3v or 5v. 71 -* 1 x one wire interface 72 -* 1 x Interrupt Interface 73 -* 1 x Controllable 5V output, max 53 +* RS485 54 +* Power Input 7~~ 24V DC. 74 74 75 75 **LoRa Spec:** 76 76 ... ... @@ -79,27 +79,30 @@ 79 79 ** Band 2 (LF): 410 ~~ 528 Mhz 80 80 * 168 dB maximum link budget. 81 81 * +20 dBm - 100 mW constant RF output vs. 63 +* +14 dBm high efficiency PA. 82 82 * Programmable bit rate up to 300 kbps. 83 83 * High sensitivity: down to -148 dBm. 84 84 * Bullet-proof front end: IIP3 = -12.5 dBm. 85 85 * Excellent blocking immunity. 68 +* Low RX current of 10.3 mA, 200 nA register retention. 86 86 * Fully integrated synthesizer with a resolution of 61 Hz. 87 -* LoRa modulation. 70 +* FSK, GFSK, MSK, GMSK, LoRaTM and OOK modulation. 88 88 * Built-in bit synchronizer for clock recovery. 89 89 * Preamble detection. 90 90 * 127 dB Dynamic Range RSSI. 91 -* Automatic RF Sense and CAD with ultra-fast AFC. 74 +* Automatic RF Sense and CAD with ultra-fast AFC. 75 +* Packet engine up to 256 bytes with CRC. 92 92 93 93 == 1.3 Features == 94 94 95 -* LoRaWAN Class A & Class C protocol (default Class A)79 +* LoRaWAN Class A & Class C protocol (default Class C) 96 96 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865/RU864 97 97 * AT Commands to change parameters 98 -* Remote configure parameters via LoRa WANDownlink82 +* Remote configure parameters via LoRa Downlink 99 99 * Firmware upgradable via program port 100 100 * Support multiply RS485 devices by flexible rules 101 101 * Support Modbus protocol 102 -* Support Interrupt uplink 86 +* Support Interrupt uplink (Since hardware version v1.2) 103 103 104 104 == 1.4 Applications == 105 105 ... ... @@ -112,53 +112,39 @@ 112 112 113 113 == 1.5 Firmware Change log == 114 114 115 -[[RS485- BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]]99 +[[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] 116 116 117 117 == 1.6 Hardware Change log == 118 118 119 119 ((( 120 -v1.4 121 -))) 122 - 123 123 ((( 124 -~1. Change Power IC to TPS22916 125 -))) 105 +v1.2: Add External Interrupt Pin. 126 126 127 - 128 -((( 129 -v1.3 107 +v1.0: Release 130 130 ))) 131 - 132 -((( 133 -~1. Change JP3 from KF350-8P to KF350-11P, Add one extra interface for I2C and one extra interface for one-wire 134 134 ))) 135 135 111 += 2. Power ON Device = 136 136 137 137 ((( 138 -v1.2 139 -))) 114 +The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below 140 140 116 +* Power Source VIN to RS485-LN VIN+ 117 +* Power Source GND to RS485-LN VIN- 118 + 141 141 ((( 142 - Releaseversion120 +Once there is power, the RS485-LN will be on. 143 143 ))) 144 144 145 -= 2. Pin mapping and Power ON Device = 146 - 147 -((( 148 -The RS485-BL is powered on by 8500mAh battery. To save battery life, RS485-BL is shipped with power off. User can put the jumper to power on RS485-BL. 123 +[[image:1653268091319-405.png]] 149 149 ))) 150 150 151 -[[image:1652953055962-143.png||height="387" width="728"]] 152 - 153 - 154 -The Left TXD and RXD are TTL interface for external sensor. TTL level is controlled by 3.3/5v Jumper. 155 - 156 156 = 3. Operation Mode = 157 157 158 158 == 3.1 How it works? == 159 159 160 160 ((( 161 -The RS485- BL is configured as LoRaWAN OTAA ClassAmode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-BL. It will auto join the network via OTAA.131 +The RS485-LN is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-LN. It will auto join the network via OTAA. 162 162 ))) 163 163 164 164 == 3.2 Example to join LoRaWAN network == ... ... @@ -165,27 +165,32 @@ 165 165 166 166 Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 167 167 168 -[[image:1652 953414711-647.png||height="337" width="723"]]138 +[[image:1653268155545-638.png||height="334" width="724"]] 169 169 170 170 ((( 171 -The RS485-BL in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method. 172 -))) 141 +The RS485-LN in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method. The connection is as below: 173 173 143 +485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively. 144 + 145 +[[image:1653268227651-549.png||height="592" width="720"]] 146 + 174 174 ((( 175 -The LG308 is already set to connect to [[TTN V3 network >> url:https://www.thethingsnetwork.org/]]. So what we need to now is only configure the TTN V3:148 +The LG308 is already set to connect to [[TTN V3 network >>path:eu1.cloud.thethings.network/]]. So what we need to now is only configure the TTN V3: 176 176 ))) 177 177 178 178 ((( 179 -**Step 1**: Create a device in TTN V3 with the OTAA keys from RS485- BL.152 +**Step 1**: Create a device in TTN V3 with the OTAA keys from RS485-LN. 180 180 ))) 181 181 182 182 ((( 183 -Each RS485- BL is shipped with a sticker with unique device EUI:156 +Each RS485-LN is shipped with a sticker with unique device EUI: 184 184 ))) 158 +))) 185 185 186 186 [[image:1652953462722-299.png]] 187 187 188 188 ((( 163 +((( 189 189 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot: 190 190 ))) 191 191 ... ... @@ -192,13 +192,11 @@ 192 192 ((( 193 193 Add APP EUI in the application. 194 194 ))) 170 +))) 195 195 196 - 197 - 198 - 199 199 [[image:image-20220519174512-1.png]] 200 200 201 -[[image:image-20220519174512-2.png||height="32 8" width="731"]]174 +[[image:image-20220519174512-2.png||height="323" width="720"]] 202 202 203 203 [[image:image-20220519174512-3.png||height="556" width="724"]] 204 204 ... ... @@ -214,7 +214,7 @@ 214 214 215 215 216 216 ((( 217 -**Step 2**: Power on RS485- BL and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.190 +**Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 218 218 ))) 219 219 220 220 [[image:1652953568895-172.png||height="232" width="724"]] ... ... @@ -222,23 +222,19 @@ 222 222 == 3.3 Configure Commands to read data == 223 223 224 224 ((( 225 -There are plenty of RS485 and TTL level devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-BL supports flexible command set. User can use [[AT Commands or LoRaWAN Downlink>>path:#AT_COMMAND]] Command to configure how RS485-BL should read the sensor and how to handle the return from RS485 or TTL sensors. 198 +((( 199 +There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#AT_COMMAND]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices. 226 226 ))) 227 227 202 +((( 203 +(% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1 204 +))) 205 +))) 206 + 228 228 === 3.3.1 onfigure UART settings for RS485 or TTL communication === 229 229 230 -RS485- BLcan connect to eitherRS485sensorsorTTLsensor.User need to specifywhattype ofsensorneedtoconnect.209 +To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are: 231 231 232 -**~1. RS485-MODBUS mode:** 233 - 234 -AT+MOD=1 ~/~/ Support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins. 235 - 236 -**2. TTL mode:** 237 - 238 -AT+MOD=2 ~/~/ Support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins. 239 - 240 -RS485-BL default UART settings is **9600, no parity, stop bit 1**. If the sensor has a different settings, user can change the RS485-BL setting to match. 241 - 242 242 (% border="1" style="background-color:#ffffcc; color:green; width:795px" %) 243 243 |((( 244 244 **AT Commands** ... ... @@ -263,13 +263,7 @@ 263 263 |((( 264 264 AT+PARITY 265 265 )))|(% style="width:285px" %)((( 266 -((( 267 267 Set UART parity (for RS485 connection) 268 -))) 269 - 270 -((( 271 -Default Value is: no parity. 272 -))) 273 273 )))|(% style="width:347px" %)((( 274 274 ((( 275 275 AT+PARITY=0 ... ... @@ -287,7 +287,7 @@ 287 287 ))) 288 288 289 289 ((( 290 - DefaultValue is: 1bit.253 + 291 291 ))) 292 292 )))|(% style="width:347px" %)((( 293 293 ((( ... ... @@ -306,12 +306,10 @@ 306 306 === 3.3.2 Configure sensors === 307 307 308 308 ((( 309 -Some sensors might need to configure before normal operation. User can configure such sensor via PC or through RS485-BL AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**. 310 -))) 311 - 312 312 ((( 313 - When user issue an (% style="color:#4f81bd" %)**AT+CFGDEV**(%%)command,Each (% style="color:#4f81bd" %)**AT+CFGDEV**(%%)the RS485 or TTLsensors. This command will only run when user input it and won’t run during each sampling.273 +Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won’t run during each sampling. 314 314 ))) 275 +))) 315 315 316 316 (% border="1" style="background-color:#ffffcc; color:green; width:806px" %) 317 317 |**AT Commands**|(% style="width:418px" %)**Description**|(% style="width:256px" %)**Example** ... ... @@ -323,8 +323,6 @@ 323 323 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 324 324 )))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 325 325 326 -Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>path:#AT_CFGDEV]]. 327 - 328 328 === 3.3.3 Configure read commands for each sampling === 329 329 330 330 ((( ... ... @@ -406,11 +406,17 @@ 406 406 **m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command** 407 407 ))) 408 408 368 +((( 409 409 For example, if we have a RS485 sensor. The command to get sensor value is: 01 03 0B B8 00 02 46 0A. Where 01 03 0B B8 00 02 is the Modbus command to read the register 0B B8 where stored the sensor value. The 46 0A is the CRC-16/MODBUS which calculate manually. 370 +))) 410 410 372 +((( 411 411 In the RS485-BL, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same. 374 +))) 412 412 376 +((( 413 413 **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx. 378 +))) 414 414 415 415 (% border="1" class="table-bordered" %) 416 416 |((( ... ... @@ -422,26 +422,24 @@ 422 422 423 423 ))) 424 424 425 -Examples: 390 +**Examples:** 426 426 427 -1. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 392 +~1. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 428 428 429 429 If we set AT+SEARCH1=1,1E 56 34. (max 5 bytes for prefix) 430 430 431 -The valid data will be all bytes after 1E 56 34 , so it is 2e 30 58 5f 36 41 30 31 00 49 396 +The valid data will be all bytes after 1E 56 34 , so it is (% style="background-color:yellow" %)** 2e 30 58 5f 36 41 30 31 00 49** 432 432 433 -[[image:16529 54654347-831.png]]398 +[[image:1653269403619-508.png]] 434 434 400 +2. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 435 435 436 -1. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 437 - 438 438 If we set AT+SEARCH1=2, 1E 56 34+31 00 49 439 439 440 -Device will search the bytes between 1E 56 34 and 31 00 49. So it is 2e 30 58 5f 36 41 30 404 +Device will search the bytes between 1E 56 34 and 31 00 49. So it is (% style="background-color:yellow" %)** 2e 30 58 5f 36 41 30** 441 441 442 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image014.png]]406 +[[image:1653269438444-278.png]] 443 443 444 - 445 445 **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes. 446 446 447 447 |((( ... ... @@ -456,58 +456,63 @@ 456 456 457 457 * Grab bytes: 458 458 459 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image015.png]]422 +[[image:1653269551753-223.png||height="311" width="717"]] 460 460 461 461 * Grab a section. 462 462 463 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image016.png]]426 +[[image:1653269568276-930.png||height="325" width="718"]] 464 464 465 465 * Grab different sections. 466 466 467 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image017.png]]430 +[[image:1653269593172-426.png||height="303" width="725"]] 468 468 432 +(% style="color:red" %)**Note:** 469 469 470 -Note: 471 - 472 472 AT+SEARCHx and AT+DATACUTx can be used together, if both commands are set, RS485-BL will first process AT+SEARCHx on the return string and get a temporary string, and then process AT+DATACUTx on this temporary string to get the final payload. In this case, AT+DATACUTx need to set to format AT+DATACUTx=0,xx,xx where the return bytes set to 0. 473 473 474 474 Example: 475 475 476 -AT+COMMAND1=11 01 1E D0,0 438 +(% style="color:red" %)AT+COMMAND1=11 01 1E D0,0 477 477 478 -AT+SEARCH1=1,1E 56 34 440 +(% style="color:red" %)AT+SEARCH1=1,1E 56 34 479 479 480 -AT+DATACUT1=0,2,1~~5 442 +(% style="color:red" %)AT+DATACUT1=0,2,1~~5 481 481 482 -Return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 444 +(% style="color:red" %)Return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 483 483 484 -String after SEARCH command: 2e 30 58 5f 36 41 30 31 00 49 446 +(% style="color:red" %)String after SEARCH command: 2e 30 58 5f 36 41 30 31 00 49 485 485 486 -Valid payload after DataCUT command: 2e 30 58 5f 36 448 +(% style="color:red" %)Valid payload after DataCUT command: 2e 30 58 5f 36 487 487 488 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image018.png]]450 +[[image:1653269618463-608.png]] 489 489 452 +=== 3.3.4 Compose the uplink payload === 490 490 491 - 492 - 493 -1. 494 -11. 495 -111. Compose the uplink payload 496 - 454 +((( 497 497 Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.** 456 +))) 498 498 458 +((( 459 +(% style="color:#4f81bd" %)**Examples: AT+DATAUP=0** 460 +))) 499 499 500 -**Examples: AT+DATAUP=0** 462 +((( 463 +Compose the uplink payload with value returns in sequence and send with (% style="color:red" %)**A SIGNLE UPLINK**. 464 +))) 501 501 502 -Compose the uplink payload with value returns in sequence and send with **A SIGNLE UPLINK**. 503 - 466 +((( 504 504 Final Payload is 468 +))) 505 505 506 -Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx 470 +((( 471 +(% style="color:#4f81bd" %)**Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx** 472 +))) 507 507 474 +((( 508 508 Where PAYVER is defined by AT+PAYVER, below is an example screen shot. 476 +))) 509 509 510 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image019.png]]478 +[[image:1653269759169-150.png]] 511 511 512 512 513 513 ... ... @@ -555,8 +555,8 @@ 555 555 556 556 557 557 558 -1. 559 -11. 526 +1. 527 +11. 560 560 111. Uplink on demand 561 561 562 562 Except uplink periodically, RS485-BL is able to uplink on demand. The server sends downlink command to RS485-BL and RS485 will uplink data base on the command. ... ... @@ -569,8 +569,8 @@ 569 569 570 570 571 571 572 -1. 573 -11. 540 +1. 541 +11. 574 574 111. Uplink on Interrupt 575 575 576 576 Put the interrupt sensor between 3.3v_out and GPIO ext.[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]] ... ... @@ -584,7 +584,7 @@ 584 584 AT+INTMOD=3 Interrupt trigger by rising edge. 585 585 586 586 587 -1. 555 +1. 588 588 11. Uplink Payload 589 589 590 590 |**Size(bytes)**|**2**|**1**|**Length depends on the return from the commands** ... ... @@ -646,15 +646,15 @@ 646 646 647 647 * **Sensor Related Commands**: These commands are special designed for RS485-BL. User can see these commands below: 648 648 649 -1. 650 -11. 617 +1. 618 +11. 651 651 111. Common Commands: 652 652 653 653 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]] 654 654 655 655 656 -1. 657 -11. 624 +1. 625 +11. 658 658 111. Sensor related commands: 659 659 660 660 ==== Choose Device Type (RS485 or TTL) ==== ... ... @@ -960,13 +960,13 @@ 960 960 961 961 962 962 963 -1. 931 +1. 964 964 11. Buttons 965 965 966 966 |**Button**|**Feature** 967 967 |**RST**|Reboot RS485-BL 968 968 969 -1. 937 +1. 970 970 11. +3V3 Output 971 971 972 972 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. ... ... @@ -984,7 +984,7 @@ 984 984 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 985 985 986 986 987 -1. 955 +1. 988 988 11. +5V Output 989 989 990 990 RS485-BL has a Controllable +5V output, user can use this output to power external sensor. ... ... @@ -1004,13 +1004,13 @@ 1004 1004 1005 1005 1006 1006 1007 -1. 975 +1. 1008 1008 11. LEDs 1009 1009 1010 1010 |**LEDs**|**Feature** 1011 1011 |**LED1**|Blink when device transmit a packet. 1012 1012 1013 -1. 981 +1. 1014 1014 11. Switch Jumper 1015 1015 1016 1016 |**Switch Jumper**|**Feature** ... ... @@ -1056,7 +1056,7 @@ 1056 1056 1057 1057 1058 1058 1059 -1. 1027 +1. 1060 1060 11. Common AT Command Sequence 1061 1061 111. Multi-channel ABP mode (Use with SX1301/LG308) 1062 1062 ... ... @@ -1075,8 +1075,8 @@ 1075 1075 1076 1076 ATZ 1077 1077 1078 -1. 1079 -11. 1046 +1. 1047 +11. 1080 1080 111. Single-channel ABP mode (Use with LG01/LG02) 1081 1081 1082 1082 AT+FDR Reset Parameters to Factory Default, Keys Reserve ... ... @@ -1151,7 +1151,7 @@ 1151 1151 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]] 1152 1152 1153 1153 1154 -1. 1122 +1. 1155 1155 11. How to change the LoRa Frequency Bands/Region? 1156 1156 1157 1157 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download. ... ... @@ -1158,7 +1158,7 @@ 1158 1158 1159 1159 1160 1160 1161 -1. 1129 +1. 1162 1162 11. How many RS485-Slave can RS485-BL connects? 1163 1163 1164 1164 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]]. ... ... @@ -1175,7 +1175,7 @@ 1175 1175 1176 1176 1177 1177 1178 -1. 1146 +1. 1179 1179 11. Why I can’t join TTN V3 in US915 /AU915 bands? 1180 1180 1181 1181 It might about the channels mapping. Please see for detail.
- 1653266934636-343.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +176.5 KB - Content
- 1653267211009-519.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +138.7 KB - Content
- 1653268091319-405.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +399.3 KB - Content
- 1653268155545-638.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +113.7 KB - Content
- 1653268227651-549.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.3 MB - Content
- 1653269403619-508.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.8 KB - Content
- 1653269438444-278.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.6 KB - Content
- 1653269551753-223.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +138.7 KB - Content
- 1653269568276-930.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +131.4 KB - Content
- 1653269593172-426.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +142.6 KB - Content
- 1653269618463-608.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.7 KB - Content
- 1653269759169-150.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +294.0 KB - Content