Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Karry Zhuang on 2025/03/06 16:34
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -RS485-L N– RS485 to LoRaWAN Converter1 +RS485-BL – Waterproof RS485 to LoRaWAN Converter - Content
-
... ... @@ -303,101 +303,87 @@ 303 303 ))) 304 304 ))) 305 305 306 -=== 3.3.2 Configure sensors === 307 307 308 -((( 309 -Some sensors might need to configure before normal operation. User can configure such sensor via PC or through RS485-BL AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**. 310 -))) 311 311 312 -((( 313 -When user issue an (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) command, Each (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) equals to send a command to the RS485 or TTL sensors. This command will only run when user input it and won’t run during each sampling. 314 -))) 315 315 316 -(% border="1" style="background-color:#ffffcc; color:green; width:806px" %) 317 -|**AT Commands**|(% style="width:418px" %)**Description**|(% style="width:256px" %)**Example** 318 -|AT+CFGDEV|(% style="width:418px" %)((( 309 +1. 310 +11. 311 +111. Configure sensors 312 + 313 +Some sensors might need to configure before normal operation. User can configure such sensor via PC or through RS485-BL AT Commands AT+CFGDEV. 314 + 315 + 316 +When user issue an AT+CFGDEV command, Each AT+CFGDEV equals to send a command to the RS485 or TTL sensors. This command will only run when user input it and won’t run during each sampling. 317 + 318 +|**AT Commands**|**Description**|**Example** 319 +|AT+CFGDEV|((( 319 319 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 320 320 321 -AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 322 +AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 322 322 323 -m m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command324 -)))| (% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m324 +m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 325 +)))|AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 325 325 326 326 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>path:#AT_CFGDEV]]. 327 327 328 -=== 3.3.3 Configure read commands for each sampling === 329 329 330 -((( 330 + 331 + 332 + 333 +1. 334 +11. 335 +111. Configure read commands for each sampling 336 + 331 331 RS485-BL is a battery powered device; it will sleep most of time. And wake up on each period and read RS485 / TTL sensor data and uplink. 332 -))) 333 333 334 - (((339 + 335 335 During each sampling, we need to confirm what commands we need to send to the sensors to read data. After the RS485/TTL sensors send back the value, it normally includes some bytes and we only need a few from them for a shorten payload. 336 -))) 337 337 338 - (((342 + 339 339 To save the LoRaWAN network bandwidth, we might need to read data from different sensors and combine their valid value into a short payload. 340 -))) 341 341 342 - (((345 + 343 343 This section describes how to achieve above goals. 344 -))) 345 345 346 - (((348 + 347 347 During each sampling, the RS485-BL can support 15 commands to read sensors. And combine the return to one or several uplink payloads. 348 -))) 349 349 350 - (((351 + 351 351 **Command from RS485-BL to Sensor:** 352 -))) 353 353 354 -((( 355 355 RS485-BL can send out pre-set max 15 strings via **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF** . All commands are of same grammar. 356 -))) 357 357 358 - (((356 + 359 359 **Handle return from sensors to RS485-BL**: 360 -))) 361 361 362 -((( 363 363 After RS485-BL send out a string to sensor, RS485-BL will wait for the return from RS485 or TTL sensor. And user can specify how to handle the return, by **AT+DATACUT or AT+SEARCH commands** 364 -))) 365 365 366 -* ((( 367 -**AT+DATACUT** 368 -))) 369 369 370 -((( 362 +* **AT+DATACUT** 363 + 371 371 When the return value from sensor have fix length and we know which position the valid value we should get, we can use AT+DATACUT command. 372 -))) 373 373 374 -* ((( 375 -**AT+SEARCH** 376 -))) 377 377 378 -((( 367 +* **AT+SEARCH** 368 + 379 379 When the return value from sensor is dynamic length and we are not sure which bytes the valid data is, instead, we know what value the valid value following. We can use AT+SEARCH to search the valid value in the return string. 380 -))) 381 381 382 - (((371 + 383 383 **Define wait timeout:** 384 -))) 385 385 386 -((( 387 387 Some RS485 device might has longer delay on reply, so user can use AT+CMDDL to set the timeout for getting reply after the RS485 command is sent. For example, AT+CMDDL1=1000 to send the open time to 1000ms 388 -))) 389 389 390 - (((376 + 391 391 After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**. 392 -))) 393 393 379 + 394 394 **Examples:** 395 395 396 396 Below are examples for the how above AT Commands works. 397 397 384 + 398 398 **AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is: 399 399 400 -(% border="1" class="table-bordered" %) 401 401 |((( 402 402 **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m** 403 403 ... ... @@ -410,9 +410,9 @@ 410 410 411 411 In the RS485-BL, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same. 412 412 399 + 413 413 **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx. 414 414 415 -(% border="1" class="table-bordered" %) 416 416 |((( 417 417 **AT+SEARCHx=aa,xx xx xx xx xx** 418 418 ... ... @@ -430,7 +430,7 @@ 430 430 431 431 The valid data will be all bytes after 1E 56 34 , so it is 2e 30 58 5f 36 41 30 31 00 49 432 432 433 -[[image: 1652954654347-831.png]]419 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image013.png]] 434 434 435 435 436 436 1. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
- 1652954654347-831.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -138.7 KB - Content