... ... @@ -618,7 +618,7 @@
618 618  
619 619  When the dry contact is closed, INT and VIN+ conduct and INT is high.
620 620  
621 -Disconnecting the dry contact, the level of the INT pin changes from high to low, triggering an interrupt (triggered by the falling edge along the interrupt), and the RS485-LN sends an uplink data.
621 +Disconnecting the dry contact, the level of the INT pin changes from high to low, triggering an interrupt (triggered along the falling edge), and the RS485-LN sends an uplink data.
622 622  
623 623  [[image:image-20240925174124-5.jpeg||height="439" width="703"]]
624 624  
... ... @@ -632,7 +632,13 @@
632 632  
633 633  [[image:image-20240925173243-4.jpeg||height="404" width="900"]]
634 634  
635 +* Example of interrupt data in TTN.
635 635  
637 +The first byte of the payload of the interrupted packet is (% style="color:blue" %)**0x81**(%%).
638 +
639 +[[image:image-20240925181010-1.png||height="348" width="953"]]
640 +
641 +
636 636  == 3.4 Uplink Payload ==
637 637  
638 638  
image-20240928101229-1.jpeg
Author
... ... @@ -1,0 +1,1 @@