571 571  === 3.3.7 Uplink on Interrupt ===
572 572  
573 573  
574 -
575 575  RS485-LN support external Interrupt uplink since hardware v1.2 release.
576 576  
577 577  (% aria-label="1654157342174-798.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654157342174-798.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]]
578 578  
578 +(% title="Click and drag to resize" %)​(%%)When there is a high voltage (3.3v and above, the maximum is 24V, but not more than 12v is recommended) on (% style="color:blue" %)**INT**(%%) pin. At this point, an interrupt is triggered and the Device will send an uplink packet.
579 579  
580 -==== 3.3.7.1 Set Interrupt Mode ====
581 -
582 -
583 -Before using the interrupt function of the **INT** pin, users can set the interrupt triggering mode as required.
584 -
585 -(% style="color:blue" %)**AT command:**
586 -
587 -* (% style="color:#037691" %)**AT+INTMOD **(%%) ~/~/ Set the trigger interrupt mode
588 -
589 -* (% style="color:#037691" %)**AT+INTMOD=0 **(%%) ~/~/ Disable Interrupt
590 -
591 -* (% style="color:#037691" %)**AT+INTMOD=1 **(%%) ~/~/ Trigger by rising and falling edge
592 -
593 -* (% style="color:#037691" %)**AT+INTMOD=2 **(%%) ~/~/ Trigger by falling edge **(default)**
594 -
595 -* (% style="color:#037691" %)**AT+INTMOD=3  **(%%) ~/~/ Trigger by rising edge
596 -
597 -(% style="color:blue" %)**Downlink Commands: **(% style="color:#037691" %)**0x06**
598 -
599 -Format: Command Code (0x06) followed by 3 bytes.
600 -
601 -Example1:  Downlink Payload: **06 00 00 01    **~/~/ AT+INTMOD=1
602 -
603 -Example2:  Downlink Payload: **06 00 00 03    **~/~/AT+INTMOD=3
604 -
605 -
606 -==== 3.3.7.2 Practical application ====
607 -
608 -
609 -The following uses the default interrupt triggering mode (% style="color:blue" %)**(AT+INTMOD=2)**(%%) as an example to show the interrupt function of (% style="color:blue" %)**INT**(%%):
610 -
611 -When a high voltage is given to the INT pin and then the level of the (% style="color:blue" %)**INT**(%%) pin changes from high to low, the interrupt is triggered by a falling edge and the RS485-LN sends an uplink data.
612 -
613 -(% style="color:red" %)**Note: The voltage ranges from 3.3V to 24V. Generally, it is recommended to use less than 12V.**
614 -
615 615  **Example:**
616 616  
617 617  * Use a dry contact to connect the (% style="color:blue" %)**INT**(%%) pin and (% style="color:blue" %)**VIN+**(%%) pin of the RS485-LN.
618 618  
619 -When the dry contact is closed, INT and VIN+ conduct and INT is high.
584 +When the dry contact is closed, INT and VIN+ conduct, and INT goes high, which triggers an interrupt, and the node sends an uplink data.
620 620  
621 -Disconnecting the dry contact, the level of the INT pin changes from high to low, triggering an interrupt (triggered by the falling edge along the interrupt), and the RS485-LN sends an uplink data.
622 -
623 623  [[image:image-20240925164510-3.jpeg||height="414" width="656"]]
624 624  
625 625  * Use a regulated power supply or a wet contact to connect the 485-LN to trigger the interruption.(This section uses a regulated power supply as an example.)
... ... @@ -626,13 +626,12 @@
626 626  
627 627  The positive pole of the stabilized power supply is connected to the (% style="color:blue" %)**INT**(%%) pin of RS485-LN, and the negative pole of the stabilized power supply is connected to the (% style="color:blue" %)**VIN-**(%%) pin of RS485-LN.
628 628  
629 -When the regulated power supply is operating, a high voltage is given to the INT pin and the INT level is high. When the regulated power supply is turned off, the level of the INT pin changes from
592 +When the regulated power supply is turned on, given a high voltage to the INT pin, an interrupt will be triggered and the device will send an uplink data.
630 630  
631 -high to low, at which time an interrupt is triggered (triggered along the falling edge), and the device will send an uplink data.
632 632  
633 -[[image:image-20240925173243-4.jpeg||height="404" width="900"]]
634 634  
635 635  
597 +
636 636  == 3.4 Uplink Payload ==
637 637  
638 638  
image-20240925174124-5.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.ting
Size
... ... @@ -1,1 +1,0 @@
1 -857.8 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0