Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -581,11 +581,20 @@ 581 581 582 582 * Use a dry contact to connect the (% style="color:blue" %)**INT**(%%) pin and (% style="color:blue" %)**VIN+**(%%) pin of the RS485-LN. 583 583 584 -When the dry contact is closed, INT and VIN+ conduct, and INT goes high, which triggers an interrupt, and the node sends an uplink message.584 +When the dry contact is closed, INT and VIN+ conduct, and INT goes high, which triggers an interrupt, and the node sends an uplink data. 585 585 586 +[[image:image-20240925164510-3.jpeg||height="414" width="656"]] 586 586 588 +* Use a regulated power supply or a wet contact to connect the 485-LN to trigger the interruption.(This section uses a regulated power supply as an example.) 587 587 590 +The positive pole of the stabilized power supply is connected to the (% style="color:blue" %)**INT**(%%) pin of RS485-LN, and the negative pole of the stabilized power supply is connected to the (% style="color:blue" %)**VIN-**(%%) pin of RS485-LN. 588 588 592 +When the regulated power supply is turned on, given a high voltage to the INT pin, an interrupt will be triggered and the device will send an uplink data. 593 + 594 + 595 + 596 + 597 + 589 589 == 3.4 Uplink Payload == 590 590 591 591
- image-20240925164510-3.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +850.5 KB - Content