<
From version < 113.1 >
edited by Bei Jinggeng
on 2024/06/20 14:56
To version < 118.1 >
edited by Mengting Qiu
on 2024/09/25 14:56
>
Change comment: Uploaded new attachment "image-20240925145611-2.jpeg", version {1}

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.ting
Content
... ... @@ -736,31 +736,21 @@
736 736  )))
737 737  
738 738  (((
739 -(% style="color:blue" %)**Example 2:**  (%%) ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
739 +(% style="color:blue" %)**Example 2:**  (%%)
740 740  )))
741 741  
742 742  (((
743 -User in IoT server send a downlink command: (% style="color:#4f81bd" %)**A8 01 06 0A 08 00 04 00 01 YY**
743 +Check TTL Sensor return:
744 744  )))
745 745  
746 746  (((
747 -
748 -)))
749 -
750 750  (((
751 -(((
752 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:  **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
748 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/test/WebHome/1654132684752-193.png?rev=1.1||alt="1654132684752-193.png"]](% title="Click and drag to resize" %)​
753 753  )))
754 -
755 -
756 756  )))
757 757  
758 -(((
759 - (% aria-label="1654159460680-153.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654159460680-153.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
760 -)))
761 761  
762 762  
763 -
764 764  ==== (% style="color:blue" %)**Set Payload version**(%%) ====
765 765  
766 766  
... ... @@ -1694,7 +1694,7 @@
1694 1694  1. Check if Modbus-MTU return back the expected result to RS485-LN.
1695 1695  1. If both b) and c) has issue, we can compare PC’s output and RS485-LN output.
1696 1696  
1697 -[[image:image-20221130104310-1.png||height="380" width="680"]]
1687 +[[image:image-20240816112950-1.png||height="382" width="731"]]
1698 1698  
1699 1699  
1700 1700  Example Connection:
image-20240816112950-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.karry
Size
... ... @@ -1,0 +1,1 @@
1 +230.3 KB
Content
image-20240925144019-1.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +1.6 MB
Content
image-20240925145611-2.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +606.6 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0