... ... @@ -736,31 +736,21 @@
736 736  )))
737 737  
738 738  (((
739 -(% style="color:blue" %)**Example 2:**  (%%) ~-~-> Configure with requesting uplink and original downlink command (**YY=FF**)
739 +(% style="color:blue" %)**Example 2:**  (%%)
740 740  )))
741 741  
742 742  (((
743 -User in IoT server send a downlink command: (% style="color:#4f81bd" %)**A8 01 06 0A 08 00 04 00 01 YY**
743 +Check TTL Sensor return:
744 744  )))
745 745  
746 746  (((
747 -
748 -)))
749 -
750 750  (((
751 -(((
752 -RS485-LN got this downlink command and send (% style="color:#4f81bd" %)**0A 08 00 04 00 01 **(%%)to Modbus network. One of the RS485 sensor in the network send back Modbus reply **0A 08 00 04 00 00**. RS485-LN get this reply and combine with the original downlink command and uplink. The uplink message is:  **A8** (% style="color:#4f81bd" %)**0A 08 00 04 00  **(% style="color:red" %)**01 06** ** **(% style="color:green" %)**0A 08 00 04 00 00**
748 +[[image:http://8.211.40.43/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/test/WebHome/1654132684752-193.png?rev=1.1||alt="1654132684752-193.png"]](% title="Click and drag to resize" %)​
753 753  )))
754 -
755 -
756 756  )))
757 757  
758 -(((
759 - (% aria-label="1654159460680-153.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654159460680-153.png||data-widget="image"]](% style="background-image:url(http://wiki.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png); background:rgba(220,220,220,0.5); display:none" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %)​
760 -)))
761 761  
762 762  
763 -
764 764  ==== (% style="color:blue" %)**Set Payload version**(%%) ====
765 765  
766 766  
... ... @@ -1694,7 +1694,7 @@
1694 1694  1. Check if Modbus-MTU return back the expected result to RS485-LN.
1695 1695  1. If both b) and c) has issue, we can compare PC’s output and RS485-LN output.
1696 1696  
1697 -[[image:image-20221130104310-1.png||height="380" width="680"]]
1687 +[[image:image-20240816112950-1.png||height="382" width="731"]]
1698 1698  
1699 1699  
1700 1700  Example Connection:
... ... @@ -1816,12 +1816,36 @@
1816 1816  Please see this link for debug: [[LoRaWAN Communication Debug>>doc:Main.LoRaWAN Communication Debug.WebHome]]
1817 1817  
1818 1818  
1819 -== 7.2 Why I can't join TTN V3 in US915 /AU915 bands? ==
1809 +== 7.2 Why customers can't join TTN V3 in US915 /AU915 bands? ==
1820 1820  
1821 1821  
1822 1822  It might about the channels mapping. Please see for detail: [[Notice of Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1823 1823  
1824 1824  
1815 +== 7.3 Why can't customers see the device's data in the server when the data is too long? ==
1816 +
1817 +This is due to the limitation of the lorawan protocol, and the fixed DR needs to be adjusted to improve this problem.
1818 +
1819 +Please refer to the following link for the number of bytes limited by different frequencies and different DRs in the lorawan protocol
1820 +
1821 +[[lora-alliance.org/wp-content/uploads/2021/05/RP002-1.0.3-FINAL-1.pdf>>url:https://lora-alliance.org/wp-content/uploads/2021/05/RP002-1.0.3-FINAL-1.pdf]]
1822 +
1823 +Example:
1824 +
1825 +[[image:image-20240620145456-1.png]]
1826 +
1827 +Please refer to the following command to fix DR
1828 +
1829 +AT+ADR=0
1830 +
1831 +AT+DR=3
1832 +
1833 +Downlink command:
1834 +
1835 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.4DataRate]]
1836 +
1837 +
1838 +
1825 1825  = 8. Order Info =
1826 1826  
1827 1827  
image-20240816112950-1.png
Author
... ... @@ -1,0 +1,1 @@