From version < 111.1 >
edited by Bei Jinggeng
on 2024/02/23 17:47
To version < 109.2 >
edited by Xiaoling
on 2023/12/20 17:51
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.Xiaoling
Content
... ... @@ -281,17 +281,19 @@
281 281  )))
282 282  )))
283 283  
284 -==== 3.3.2.1 Configure UART settings for RS485 communication ====
284 +==== 3.3.2.1 Configure UART settings for RS485 or TTL communication ====
285 285  
286 286  
287 -To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. The related commands for UART settings are:
287 +RS485-LN can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect.
288 288  
289 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
290 -|=(% style="width: 126px; background-color:#4F81BD;color:white" %)(((
289 +To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
290 +
291 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
292 +|=(% style="width: 126px; background-color:#D9E2F3;color:#0070C0" %)(((
291 291  **AT Commands**
292 -)))|=(% style="width: 187px; background-color:#4F81BD;color:white" %)(((
294 +)))|=(% style="width: 187px; background-color:#D9E2F3;color:#0070C0" %)(((
293 293  **Description**
294 -)))|=(% style="width: 197px;background-color:#4F81BD;color:white" %)(((
296 +)))|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)(((
295 295  **Example**
296 296  )))
297 297  |(% style="width:126px" %)(((
... ... @@ -354,8 +354,8 @@
354 354  Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won't run during each sampling.
355 355  )))
356 356  
357 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
358 -|=(% style="width: 122px; background-color:#4F81BD;color:white" %)**AT Commands**|=(% style="width: 198px; background-color:#4F81BD;color:white" %)**Description**|=(% style="width: 190px;background-color:#4F81BD;color:white" %)**Example**
359 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
360 +|=(% style="width: 122px; background-color:#D9E2F3;color:#0070C0" %)**AT Commands**|=(% style="width: 198px; background-color:#D9E2F3;color:#0070C0" %)**Description**|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)**Example**
359 359  |(% style="width:122px" %)AT+CFGDEV|(% style="width:196px" %)(((
360 360  (((
361 361  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
... ... @@ -571,10 +571,10 @@
571 571  == 3.4 Uplink Payload ==
572 572  
573 573  
574 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
575 -|(% style="background-color:#4f81bd; color:white; width:70px" %)(((
576 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
577 +|(% style="background-color:#d9e2f3; color:#0070c0; width:70px" %)(((
576 576  **Size(bytes)**
577 -)))|(% style="background-color:#4f81bd; color:white; width:80px" %)**1**|(% style="background-color:#4f81bd; color:white; width:360px" %)(((
579 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:80px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:360px" %)(((
578 578  **Length depends on the return from the commands**
579 579  )))
580 580  |(% style="width:90px" %)(((
... ... @@ -1386,10 +1386,10 @@
1386 1386  To enable the listening mode, use can run the command (% style="color:#4472c4" %)** AT+RXMODE**.
1387 1387  )))
1388 1388  
1389 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
1390 -|=(% style="width: 156px; background-color:#4F81BD;color:white" %)(((
1391 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
1392 +|=(% style="width: 156px; background-color:#D9E2F3;color:#0070C0" %)(((
1391 1391  **Command example**
1392 -)))|=(% style="width: 355px; background-color:#4F81BD;color:white" %)(((
1394 +)))|=(% style="width: 355px; background-color:#D9E2F3;color:#0070C0" %)(((
1393 1393  **Function**
1394 1394  )))
1395 1395  |(% style="width:156px" %)(((
... ... @@ -1468,7 +1468,7 @@
1468 1468  
1469 1469  
1470 1470  (% border="1.5" cellspacing="4" style="background-color:#f2f2f2; width:430px" %)
1471 -|=(% style="width: 50px;background-color:#4F81BD;color:white" %)**Button**|=(% style="width: 380px;background-color:#4F81BD;color:white" %)**Feature**
1473 +|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)**Button**|=(% style="width: 380px;background-color:#D9E2F3;color:#0070C0" %)**Feature**
1472 1472  |(% style="width:50px" %)ACT|(% style="width:361px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1473 1473  |(% style="width:50px" %)RST|(% style="width:361px" %)Reboot RS485
1474 1474  |(% style="width:50px" %)PRO|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
... ... @@ -1477,7 +1477,7 @@
1477 1477  
1478 1478  
1479 1479  (% border="1.5" cellspacing="4" style="background-color:#f2f2f2; width:430px" %)
1480 -|=(% style="width: 50px;background-color:#4F81BD;color:white" %)**LEDs**|=(% style="width: 380px;background-color:#4F81BD;color:white" %)**Feature**
1482 +|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)**LEDs**|=(% style="width: 380px;background-color:#D9E2F3;color:#0070C0" %)**Feature**
1481 1481  |PWR|Always on if there is power
1482 1482  |SYS|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1483 1483  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved