Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/10 15:06
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -283,16 +283,16 @@ 283 283 284 284 285 285 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 286 -|=(% style="width: 1 20px;background-color:#D9E2F3;color:#0070C0" %)(((286 +|=(% style="width: 119px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)((( 287 287 **AT Commands** 288 -)))|=(% style="width: 200px;background-color:#D9E2F3;color:#0070C0" %)(((288 +)))|=(% style="width: 116px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)((( 289 289 **Description** 290 290 )))|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)((( 291 291 **Example** 292 292 ))) 293 -|(% style="width:11 0px" %)(((293 +|(% style="width:119px" %)((( 294 294 AT+BAUDR 295 -)))|(% style="width:1 90px" %)(((295 +)))|(% style="width:116px" %)((( 296 296 Set the baud rate (for RS485 connection). Default Value is: 9600. 297 297 )))|(% style="width:190px" %)((( 298 298 ((( ... ... @@ -303,9 +303,9 @@ 303 303 Options: (1200,2400,4800,14400,19200,115200) 304 304 ))) 305 305 ))) 306 -|(% style="width:11 0px" %)(((306 +|(% style="width:119px" %)((( 307 307 AT+PARITY 308 -)))|(% style="width:1 90px" %)(((308 +)))|(% style="width:116px" %)((( 309 309 Set UART parity (for RS485 connection) 310 310 )))|(% style="width:190px" %)((( 311 311 ((( ... ... @@ -316,9 +316,9 @@ 316 316 Option: 0: no parity, 1: odd parity, 2: even parity 317 317 ))) 318 318 ))) 319 -|(% style="width:11 0px" %)(((319 +|(% style="width:119px" %)((( 320 320 AT+STOPBIT 321 -)))|(% style="width:1 90px" %)(((321 +)))|(% style="width:116px" %)((( 322 322 ((( 323 323 Set serial stopbit (for RS485 connection) 324 324 ))) ... ... @@ -352,8 +352,8 @@ 352 352 ))) 353 353 354 354 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %) 355 -|=(% style="width: 1 10px;background-color:#D9E2F3;color:#0070C0" %)**AT Commands**|=(% style="width:210px;background-color:#D9E2F3;color:#0070C0" %)**Description**|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)**Example**356 -|AT+CFGDEV|(% style="width:1 10px" %)(((355 +|=(% style="width: 122px; background-color:#D9E2F3;color:#0070C0" %)**AT Commands**|=(% style="width: 198px; background-color:#D9E2F3;color:#0070C0" %)**Description**|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)**Example** 356 +|(% style="width:122px" %)AT+CFGDEV|(% style="width:196px" %)((( 357 357 ((( 358 358 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 359 359 ))) ... ... @@ -397,7 +397,7 @@ 397 397 398 398 (% style="color:#037691" %)**AT+COMMANDx **(%%)**: **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is: 399 399 400 -(% border="1" style="background-color:# 4bacc6;color:white; width:499px" %)400 +(% border="1" style="background-color:#f2f2f2; width:499px" %) 401 401 |(% style="width:496px" %)((( 402 402 **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m** 403 403 ... ... @@ -413,7 +413,7 @@ 413 413 414 414 (% style="color:#037691" %)**AT+DATACUTx **(%%)**: **This command defines how to handle the return from AT+COMMANDx, max return length is 100 bytes. 415 415 416 -(% border="1" style="background-color:# 4bacc6;color:white; width:510px" %)416 +(% border="1" style="background-color:#f2f2f2; width:510px" %) 417 417 |(% style="width:510px" %)((( 418 418 **AT+DATACUTx=a,b,c** 419 419