From version < 102.19 >
edited by Xiaoling
on 2023/04/25 17:53
To version < 102.13 >
edited by Xiaoling
on 2023/04/25 12:00
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -94,8 +94,6 @@
94 94  * Automatic RF Sense and CAD with ultra-fast AFC.
95 95  * Packet engine up to 256 bytes with CRC
96 96  
97 -
98 -
99 99  == 1.3 Features ==
100 100  
101 101  
... ... @@ -108,8 +108,6 @@
108 108  * Support Modbus protocol
109 109  * Support Interrupt uplink (Since hardware version v1.2)
110 110  
111 -
112 -
113 113  == 1.4 Applications ==
114 114  
115 115  
... ... @@ -120,8 +120,6 @@
120 120  * Smart Cities
121 121  * Smart Factory
122 122  
123 -
124 -
125 125  == 1.5 Firmware Change log ==
126 126  
127 127  
... ... @@ -287,55 +287,53 @@
287 287  
288 288  To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
289 289  
284 +
290 290  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
291 -|=(% style="width: 126px; background-color:#D9E2F3;color:#0070C0" %)(((
286 +|=(% style="width: 119px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)(((
292 292  **AT Commands**
293 -)))|=(% style="width: 187px; background-color:#D9E2F3;color:#0070C0" %)(((
288 +)))|=(% style="width: 116px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)(((
294 294  **Description**
295 -)))|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)(((
290 +)))|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)(((
296 296  **Example**
297 297  )))
298 -|(% style="width:126px" %)(((
299 -
300 -
301 -(((
293 +|(% style="width:119px" %)(((
302 302  AT+BAUDR
303 -)))
304 -)))|(% style="width:177px" %)(((
295 +)))|(% style="width:116px" %)(((
305 305  Set the baud rate (for RS485 connection). Default Value is: 9600.
306 -)))|(% style="width:193px" %)(((
297 +)))|(% style="width:190px" %)(((
307 307  (((
308 308  AT+BAUDR=9600
309 309  )))
310 310  
311 311  (((
312 -Options: (1200,2400,4800,
313 -14400,19200,115200)
303 +Options: (1200,2400,4800,14400,19200,115200)
314 314  )))
315 315  )))
316 -|(% style="width:126px" %)(((
306 +|(% style="width:119px" %)(((
317 317  AT+PARITY
318 -)))|(% style="width:177px" %)(((
308 +)))|(% style="width:116px" %)(((
319 319  Set UART parity (for RS485 connection)
320 -)))|(% style="width:193px" %)(((
310 +)))|(% style="width:190px" %)(((
321 321  (((
322 322  AT+PARITY=0
323 323  )))
324 324  
325 325  (((
326 -Option: 0: no parity,
327 -1: odd parity,
328 -2: even parity
316 +Option: 0: no parity, 1: odd parity, 2: even parity
329 329  )))
330 330  )))
331 -|(% style="width:126px" %)(((
319 +|(% style="width:119px" %)(((
332 332  AT+STOPBIT
333 -)))|(% style="width:177px" %)(((
321 +)))|(% style="width:116px" %)(((
334 334  (((
335 335  Set serial stopbit (for RS485 connection)
336 336  )))
337 -)))|(% style="width:193px" %)(((
325 +
338 338  (((
327 +
328 +)))
329 +)))|(% style="width:190px" %)(((
330 +(((
339 339  AT+STOPBIT=0 for 1bit
340 340  )))
341 341  
... ... @@ -348,14 +348,16 @@
348 348  )))
349 349  )))
350 350  
351 -
352 -
353 353  === 3.3.2 Configure sensors ===
354 354  
355 355  
356 356  (((
347 +(((
357 357  Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won't run during each sampling.
349 +
350 +
358 358  )))
352 +)))
359 359  
360 360  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
361 361  |=(% style="width: 122px; background-color:#D9E2F3;color:#0070C0" %)**AT Commands**|=(% style="width: 198px; background-color:#D9E2F3;color:#0070C0" %)**Description**|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)**Example**
... ... @@ -373,8 +373,6 @@
373 373  )))
374 374  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
375 375  
376 -
377 -
378 378  === 3.3.3 Configure read commands for each sampling ===
379 379  
380 380  
... ... @@ -564,7 +564,7 @@
564 564  
565 565  
566 566  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
567 -|=(% scope="row" style="width: 70px;background-color:#D9E2F3;color:#0070C0" %)(((
559 +|=(% scope="row" style="width: 60px;background-color:#D9E2F3;color:#0070C0" %)(((
568 568  Size(bytes)
569 569  )))|(% style="background-color:#d9e2f3; color:#0070c0; width:80px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:360px" %)(((
570 570  **Length depends on the return from the commands**
... ... @@ -1427,8 +1427,6 @@
1427 1427  |(% style="width:50px" %)RST|(% style="width:361px" %)Reboot RS485
1428 1428  |(% style="width:50px" %)PRO|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1429 1429  
1430 -
1431 -
1432 1432  == 3.8 LEDs ==
1433 1433  
1434 1434  
... ... @@ -1437,8 +1437,6 @@
1437 1437  |PWR|Always on if there is power
1438 1438  |SYS|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1439 1439  
1440 -
1441 -
1442 1442  = 4. Case Study =
1443 1443  
1444 1444  
... ... @@ -1781,8 +1781,6 @@
1781 1781  * (% style="color:red" %)**RU864**(%%):  frequency bands RU864
1782 1782  * (% style="color:red" %)**KZ865**(%%):  frequency bands KZ865
1783 1783  
1784 -
1785 -
1786 1786  = 9. Packing Info =
1787 1787  
1788 1788  
... ... @@ -1799,8 +1799,6 @@
1799 1799  * Package Size / pcs : 14.5 x 8 x 5 cm
1800 1800  * Weight / pcs : 170g
1801 1801  
1802 -
1803 -
1804 1804  = 10. FCC Caution for RS485LN-US915 =
1805 1805  
1806 1806  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0