From version < 102.16 >
edited by Xiaoling
on 2023/04/25 14:05
To version < 102.11 >
edited by Xiaoling
on 2023/04/25 11:38
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -281,53 +281,44 @@
281 281  
282 282  To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
283 283  
284 +
284 284  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
285 -|=(% style="width: 126px; background-color:#D9E2F3;color:#0070C0" %)(((
286 +|=(% style="width: 119px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)(((
286 286  **AT Commands**
287 -)))|=(% style="width: 187px; background-color:#D9E2F3;color:#0070C0" %)(((
288 +)))|=(% style="width: 116px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)(((
288 288  **Description**
289 -)))|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)(((
290 +)))|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)(((
290 290  **Example**
291 291  )))
292 -|(% style="width:126px" %)(((
293 -
294 -
295 -(((
293 +|(% style="width:119px" %)(((
296 296  AT+BAUDR
297 -)))
298 -)))|(% style="width:177px" %)(((
295 +)))|(% style="width:116px" %)(((
299 299  Set the baud rate (for RS485 connection). Default Value is: 9600.
300 -)))|(% style="width:193px" %)(((
297 +)))|(% style="width:190px" %)(((
301 301  (((
302 302  AT+BAUDR=9600
303 303  )))
304 304  
305 305  (((
306 -Options: (1200,2400,4800,
307 -
308 -14400,19200,115200)
303 +Options: (1200,2400,4800,14400,19200,115200)
309 309  )))
310 310  )))
311 -|(% style="width:126px" %)(((
306 +|(% style="width:119px" %)(((
312 312  AT+PARITY
313 -)))|(% style="width:177px" %)(((
308 +)))|(% style="width:116px" %)(((
314 314  Set UART parity (for RS485 connection)
315 -)))|(% style="width:193px" %)(((
310 +)))|(% style="width:190px" %)(((
316 316  (((
317 317  AT+PARITY=0
318 318  )))
319 319  
320 320  (((
321 -Option: 0: no parity,
322 -
323 -1: odd parity,
324 -
325 -2: even parity
316 +Option: 0: no parity, 1: odd parity, 2: even parity
326 326  )))
327 327  )))
328 -|(% style="width:126px" %)(((
319 +|(% style="width:119px" %)(((
329 329  AT+STOPBIT
330 -)))|(% style="width:177px" %)(((
321 +)))|(% style="width:116px" %)(((
331 331  (((
332 332  Set serial stopbit (for RS485 connection)
333 333  )))
... ... @@ -335,7 +335,7 @@
335 335  (((
336 336  
337 337  )))
338 -)))|(% style="width:193px" %)(((
329 +)))|(% style="width:190px" %)(((
339 339  (((
340 340  AT+STOPBIT=0 for 1bit
341 341  )))
... ... @@ -349,13 +349,16 @@
349 349  )))
350 350  )))
351 351  
352 -
353 353  === 3.3.2 Configure sensors ===
354 354  
355 355  
356 356  (((
347 +(((
357 357  Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won't run during each sampling.
349 +
350 +
358 358  )))
352 +)))
359 359  
360 360  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
361 361  |=(% style="width: 122px; background-color:#D9E2F3;color:#0070C0" %)**AT Commands**|=(% style="width: 198px; background-color:#D9E2F3;color:#0070C0" %)**Description**|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)**Example**
... ... @@ -1419,19 +1419,19 @@
1419 1419  == 3.7 Buttons ==
1420 1420  
1421 1421  
1422 -(% border="1.5" cellspacing="4" style="background-color:#f2f2f2; width:430px" %)
1423 -|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)**Button**|=(% style="width: 380px;background-color:#D9E2F3;color:#0070C0" %)**Feature**
1424 -|(% style="width:50px" %)ACT|(% style="width:361px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1425 -|(% style="width:50px" %)RST|(% style="width:361px" %)Reboot RS485
1426 -|(% style="width:50px" %)PRO|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1416 +(% border="1.5" cellspacing="4" style="background-color:#ffffcc; width:430px" %)
1417 +|=(% style="width: 50px;" %)**Button**|=(% style="width: 380px;" %)**Feature**
1418 +|(% style="width:50px" %)**ACT**|(% style="width:361px" %)If RS485 joined in network, press this button for more than 1 second, RS485 will upload a packet, and the SYS LED will give a (% style="color:blue" %)**Blue blink**
1419 +|(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485
1420 +|(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1427 1427  
1428 1428  == 3.8 LEDs ==
1429 1429  
1430 1430  
1431 -(% border="1.5" cellspacing="4" style="background-color:#f2f2f2; width:430px" %)
1432 -|=(% style="width: 50px;background-color:#D9E2F3;color:#0070C0" %)**LEDs**|=(% style="width: 380px;background-color:#D9E2F3;color:#0070C0" %)**Feature**
1433 -|PWR|Always on if there is power
1434 -|SYS|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1425 +(% border="1.5" cellspacing="4" style="background-color:#ffffcc; width:430px" %)
1426 +|=(% style="width: 50px;" %)**LEDs**|=(% style="width: 380px;" %)**Feature**
1427 +|**PWR**|Always on if there is power
1428 +|**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1435 1435  
1436 1436  = 4. Case Study =
1437 1437  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0