From version < 102.15 >
edited by Xiaoling
on 2023/04/25 13:49
To version < 102.16 >
edited by Xiaoling
on 2023/04/25 14:05
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -94,8 +94,6 @@
94 94  * Automatic RF Sense and CAD with ultra-fast AFC.
95 95  * Packet engine up to 256 bytes with CRC
96 96  
97 -
98 -
99 99  == 1.3 Features ==
100 100  
101 101  
... ... @@ -108,8 +108,6 @@
108 108  * Support Modbus protocol
109 109  * Support Interrupt uplink (Since hardware version v1.2)
110 110  
111 -
112 -
113 113  == 1.4 Applications ==
114 114  
115 115  
... ... @@ -120,8 +120,6 @@
120 120  * Smart Cities
121 121  * Smart Factory
122 122  
123 -
124 -
125 125  == 1.5 Firmware Change log ==
126 126  
127 127  
... ... @@ -287,44 +287,53 @@
287 287  
288 288  To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
289 289  
290 -
291 291  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
292 -|=(% style="width: 120px; background-color:#D9E2F3;color:#0070C0" %)(((
285 +|=(% style="width: 126px; background-color:#D9E2F3;color:#0070C0" %)(((
293 293  **AT Commands**
294 -)))|=(% style="width: 195px; background-color:#D9E2F3;color:#0070C0" %)(((
287 +)))|=(% style="width: 187px; background-color:#D9E2F3;color:#0070C0" %)(((
295 295  **Description**
296 -)))|=(% style="width: 195px;background-color:#D9E2F3;color:#0070C0" %)(((
289 +)))|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)(((
297 297  **Example**
298 298  )))
299 -|(% style="width:119px" %)(((
292 +|(% style="width:126px" %)(((
293 +
294 +
295 +(((
300 300  AT+BAUDR
301 -)))|(% style="width:116px" %)(((
297 +)))
298 +)))|(% style="width:177px" %)(((
302 302  Set the baud rate (for RS485 connection). Default Value is: 9600.
303 -)))|(% style="width:190px" %)(((
300 +)))|(% style="width:193px" %)(((
304 304  (((
305 305  AT+BAUDR=9600
306 306  )))
307 307  
308 308  (((
309 -Options: (1200,2400,4800,14400,19200,115200)
306 +Options: (1200,2400,4800,
307 +
308 +14400,19200,115200)
310 310  )))
311 311  )))
312 -|(% style="width:119px" %)(((
311 +|(% style="width:126px" %)(((
313 313  AT+PARITY
314 -)))|(% style="width:116px" %)(((
313 +)))|(% style="width:177px" %)(((
315 315  Set UART parity (for RS485 connection)
316 -)))|(% style="width:190px" %)(((
315 +)))|(% style="width:193px" %)(((
317 317  (((
318 318  AT+PARITY=0
319 319  )))
320 320  
321 321  (((
322 -Option: 0: no parity, 1: odd parity, 2: even parity
321 +Option: 0: no parity,
322 +
323 +1: odd parity,
324 +
325 +2: even parity
323 323  )))
324 324  )))
325 -|(% style="width:119px" %)(((
328 +|(% style="width:126px" %)(((
326 326  AT+STOPBIT
327 -)))|(% style="width:116px" %)(((
330 +)))|(% style="width:177px" %)(((
328 328  (((
329 329  Set serial stopbit (for RS485 connection)
330 330  )))
... ... @@ -332,7 +332,7 @@
332 332  (((
333 333  
334 334  )))
335 -)))|(% style="width:190px" %)(((
338 +)))|(% style="width:193px" %)(((
336 336  (((
337 337  AT+STOPBIT=0 for 1bit
338 338  )))
... ... @@ -347,17 +347,12 @@
347 347  )))
348 348  
349 349  
350 -
351 351  === 3.3.2 Configure sensors ===
352 352  
353 353  
354 354  (((
355 -(((
356 356  Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won't run during each sampling.
357 -
358 -
359 359  )))
360 -)))
361 361  
362 362  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
363 363  |=(% style="width: 122px; background-color:#D9E2F3;color:#0070C0" %)**AT Commands**|=(% style="width: 198px; background-color:#D9E2F3;color:#0070C0" %)**Description**|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)**Example**
... ... @@ -375,8 +375,6 @@
375 375  )))
376 376  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
377 377  
378 -
379 -
380 380  === 3.3.3 Configure read commands for each sampling ===
381 381  
382 382  
... ... @@ -1429,8 +1429,6 @@
1429 1429  |(% style="width:50px" %)RST|(% style="width:361px" %)Reboot RS485
1430 1430  |(% style="width:50px" %)PRO|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1431 1431  
1432 -
1433 -
1434 1434  == 3.8 LEDs ==
1435 1435  
1436 1436  
... ... @@ -1439,8 +1439,6 @@
1439 1439  |PWR|Always on if there is power
1440 1440  |SYS|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1441 1441  
1442 -
1443 -
1444 1444  = 4. Case Study =
1445 1445  
1446 1446  
... ... @@ -1783,8 +1783,6 @@
1783 1783  * (% style="color:red" %)**RU864**(%%):  frequency bands RU864
1784 1784  * (% style="color:red" %)**KZ865**(%%):  frequency bands KZ865
1785 1785  
1786 -
1787 -
1788 1788  = 9. Packing Info =
1789 1789  
1790 1790  
... ... @@ -1801,8 +1801,6 @@
1801 1801  * Package Size / pcs : 14.5 x 8 x 5 cm
1802 1802  * Weight / pcs : 170g
1803 1803  
1804 -
1805 -
1806 1806  = 10. FCC Caution for RS485LN-US915 =
1807 1807  
1808 1808  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0