From version < 102.14 >
edited by Xiaoling
on 2023/04/25 13:41
To version < 102.19 >
edited by Xiaoling
on 2023/04/25 17:53
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -287,53 +287,55 @@
287 287  
288 288  To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
289 289  
290 -
291 291  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
292 -|=(% style="width: 119px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)(((
291 +|=(% style="width: 126px; background-color:#D9E2F3;color:#0070C0" %)(((
293 293  **AT Commands**
294 -)))|=(% style="width: 116px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)(((
293 +)))|=(% style="width: 187px; background-color:#D9E2F3;color:#0070C0" %)(((
295 295  **Description**
296 -)))|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)(((
295 +)))|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)(((
297 297  **Example**
298 298  )))
299 -|(% style="width:119px" %)(((
298 +|(% style="width:126px" %)(((
299 +
300 +
301 +(((
300 300  AT+BAUDR
301 -)))|(% style="width:116px" %)(((
303 +)))
304 +)))|(% style="width:177px" %)(((
302 302  Set the baud rate (for RS485 connection). Default Value is: 9600.
303 -)))|(% style="width:190px" %)(((
306 +)))|(% style="width:193px" %)(((
304 304  (((
305 305  AT+BAUDR=9600
306 306  )))
307 307  
308 308  (((
309 -Options: (1200,2400,4800,14400,19200,115200)
312 +Options: (1200,2400,4800,
313 +14400,19200,115200)
310 310  )))
311 311  )))
312 -|(% style="width:119px" %)(((
316 +|(% style="width:126px" %)(((
313 313  AT+PARITY
314 -)))|(% style="width:116px" %)(((
318 +)))|(% style="width:177px" %)(((
315 315  Set UART parity (for RS485 connection)
316 -)))|(% style="width:190px" %)(((
320 +)))|(% style="width:193px" %)(((
317 317  (((
318 318  AT+PARITY=0
319 319  )))
320 320  
321 321  (((
322 -Option: 0: no parity, 1: odd parity, 2: even parity
326 +Option: 0: no parity,
327 +1: odd parity,
328 +2: even parity
323 323  )))
324 324  )))
325 -|(% style="width:119px" %)(((
331 +|(% style="width:126px" %)(((
326 326  AT+STOPBIT
327 -)))|(% style="width:116px" %)(((
333 +)))|(% style="width:177px" %)(((
328 328  (((
329 329  Set serial stopbit (for RS485 connection)
330 330  )))
331 -
337 +)))|(% style="width:193px" %)(((
332 332  (((
333 -
334 -)))
335 -)))|(% style="width:190px" %)(((
336 -(((
337 337  AT+STOPBIT=0 for 1bit
338 338  )))
339 339  
... ... @@ -352,12 +352,8 @@
352 352  
353 353  
354 354  (((
355 -(((
356 356  Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won't run during each sampling.
357 -
358 -
359 359  )))
360 -)))
361 361  
362 362  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
363 363  |=(% style="width: 122px; background-color:#D9E2F3;color:#0070C0" %)**AT Commands**|=(% style="width: 198px; background-color:#D9E2F3;color:#0070C0" %)**Description**|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)**Example**
... ... @@ -566,7 +566,7 @@
566 566  
567 567  
568 568  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
569 -|=(% scope="row" style="width: 60px;background-color:#D9E2F3;color:#0070C0" %)(((
567 +|=(% scope="row" style="width: 70px;background-color:#D9E2F3;color:#0070C0" %)(((
570 570  Size(bytes)
571 571  )))|(% style="background-color:#d9e2f3; color:#0070c0; width:80px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:360px" %)(((
572 572  **Length depends on the return from the commands**
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved