From version < 102.13 >
edited by Xiaoling
on 2023/04/25 12:00
To version < 102.19 >
edited by Xiaoling
on 2023/04/25 17:53
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -94,6 +94,8 @@
94 94  * Automatic RF Sense and CAD with ultra-fast AFC.
95 95  * Packet engine up to 256 bytes with CRC
96 96  
97 +
98 +
97 97  == 1.3 Features ==
98 98  
99 99  
... ... @@ -106,6 +106,8 @@
106 106  * Support Modbus protocol
107 107  * Support Interrupt uplink (Since hardware version v1.2)
108 108  
111 +
112 +
109 109  == 1.4 Applications ==
110 110  
111 111  
... ... @@ -116,6 +116,8 @@
116 116  * Smart Cities
117 117  * Smart Factory
118 118  
123 +
124 +
119 119  == 1.5 Firmware Change log ==
120 120  
121 121  
... ... @@ -281,53 +281,55 @@
281 281  
282 282  To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
283 283  
284 -
285 285  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
286 -|=(% style="width: 119px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)(((
291 +|=(% style="width: 126px; background-color:#D9E2F3;color:#0070C0" %)(((
287 287  **AT Commands**
288 -)))|=(% style="width: 116px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)(((
293 +)))|=(% style="width: 187px; background-color:#D9E2F3;color:#0070C0" %)(((
289 289  **Description**
290 -)))|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)(((
295 +)))|=(% style="width: 197px;background-color:#D9E2F3;color:#0070C0" %)(((
291 291  **Example**
292 292  )))
293 -|(% style="width:119px" %)(((
298 +|(% style="width:126px" %)(((
299 +
300 +
301 +(((
294 294  AT+BAUDR
295 -)))|(% style="width:116px" %)(((
303 +)))
304 +)))|(% style="width:177px" %)(((
296 296  Set the baud rate (for RS485 connection). Default Value is: 9600.
297 -)))|(% style="width:190px" %)(((
306 +)))|(% style="width:193px" %)(((
298 298  (((
299 299  AT+BAUDR=9600
300 300  )))
301 301  
302 302  (((
303 -Options: (1200,2400,4800,14400,19200,115200)
312 +Options: (1200,2400,4800,
313 +14400,19200,115200)
304 304  )))
305 305  )))
306 -|(% style="width:119px" %)(((
316 +|(% style="width:126px" %)(((
307 307  AT+PARITY
308 -)))|(% style="width:116px" %)(((
318 +)))|(% style="width:177px" %)(((
309 309  Set UART parity (for RS485 connection)
310 -)))|(% style="width:190px" %)(((
320 +)))|(% style="width:193px" %)(((
311 311  (((
312 312  AT+PARITY=0
313 313  )))
314 314  
315 315  (((
316 -Option: 0: no parity, 1: odd parity, 2: even parity
326 +Option: 0: no parity,
327 +1: odd parity,
328 +2: even parity
317 317  )))
318 318  )))
319 -|(% style="width:119px" %)(((
331 +|(% style="width:126px" %)(((
320 320  AT+STOPBIT
321 -)))|(% style="width:116px" %)(((
333 +)))|(% style="width:177px" %)(((
322 322  (((
323 323  Set serial stopbit (for RS485 connection)
324 324  )))
325 -
337 +)))|(% style="width:193px" %)(((
326 326  (((
327 -
328 -)))
329 -)))|(% style="width:190px" %)(((
330 -(((
331 331  AT+STOPBIT=0 for 1bit
332 332  )))
333 333  
... ... @@ -340,16 +340,14 @@
340 340  )))
341 341  )))
342 342  
351 +
352 +
343 343  === 3.3.2 Configure sensors ===
344 344  
345 345  
346 346  (((
347 -(((
348 348  Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won't run during each sampling.
349 -
350 -
351 351  )))
352 -)))
353 353  
354 354  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
355 355  |=(% style="width: 122px; background-color:#D9E2F3;color:#0070C0" %)**AT Commands**|=(% style="width: 198px; background-color:#D9E2F3;color:#0070C0" %)**Description**|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)**Example**
... ... @@ -367,6 +367,8 @@
367 367  )))
368 368  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
369 369  
376 +
377 +
370 370  === 3.3.3 Configure read commands for each sampling ===
371 371  
372 372  
... ... @@ -556,7 +556,7 @@
556 556  
557 557  
558 558  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
559 -|=(% scope="row" style="width: 60px;background-color:#D9E2F3;color:#0070C0" %)(((
567 +|=(% scope="row" style="width: 70px;background-color:#D9E2F3;color:#0070C0" %)(((
560 560  Size(bytes)
561 561  )))|(% style="background-color:#d9e2f3; color:#0070c0; width:80px" %)**1**|(% style="background-color:#d9e2f3; color:#0070c0; width:360px" %)(((
562 562  **Length depends on the return from the commands**
... ... @@ -1419,6 +1419,8 @@
1419 1419  |(% style="width:50px" %)RST|(% style="width:361px" %)Reboot RS485
1420 1420  |(% style="width:50px" %)PRO|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1421 1421  
1430 +
1431 +
1422 1422  == 3.8 LEDs ==
1423 1423  
1424 1424  
... ... @@ -1427,6 +1427,8 @@
1427 1427  |PWR|Always on if there is power
1428 1428  |SYS|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1429 1429  
1440 +
1441 +
1430 1430  = 4. Case Study =
1431 1431  
1432 1432  
... ... @@ -1769,6 +1769,8 @@
1769 1769  * (% style="color:red" %)**RU864**(%%):  frequency bands RU864
1770 1770  * (% style="color:red" %)**KZ865**(%%):  frequency bands KZ865
1771 1771  
1784 +
1785 +
1772 1772  = 9. Packing Info =
1773 1773  
1774 1774  
... ... @@ -1785,6 +1785,8 @@
1785 1785  * Package Size / pcs : 14.5 x 8 x 5 cm
1786 1786  * Weight / pcs : 170g
1787 1787  
1802 +
1803 +
1788 1788  = 10. FCC Caution for RS485LN-US915 =
1789 1789  
1790 1790  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0