Changes for page RS485-LN – RS485 to LoRaWAN Converter User Manual
Last modified by Bei Jinggeng on 2025/01/16 11:36
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -28,7 +28,7 @@ 28 28 29 29 30 30 31 -= 1. 31 += 1.Introduction = 32 32 33 33 == 1.1 What is RS485-LN RS485 to LoRaWAN Converter == 34 34 ... ... @@ -94,7 +94,6 @@ 94 94 * Automatic RF Sense and CAD with ultra-fast AFC. 95 95 * Packet engine up to 256 bytes with CRC 96 96 97 - 98 98 == 1.3 Features == 99 99 100 100 ... ... @@ -107,7 +107,6 @@ 107 107 * Support Modbus protocol 108 108 * Support Interrupt uplink (Since hardware version v1.2) 109 109 110 - 111 111 == 1.4 Applications == 112 112 113 113 ... ... @@ -118,7 +118,6 @@ 118 118 * Smart Cities 119 119 * Smart Factory 120 120 121 - 122 122 == 1.5 Firmware Change log == 123 123 124 124 ... ... @@ -125,6 +125,7 @@ 125 125 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]] 126 126 127 127 125 + 128 128 == 1.6 Hardware Change log == 129 129 130 130 ... ... @@ -343,7 +343,6 @@ 343 343 ))) 344 344 ))) 345 345 346 - 347 347 === 3.3.2 Configure sensors === 348 348 349 349 ... ... @@ -371,7 +371,6 @@ 371 371 ))) 372 372 )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 373 373 374 - 375 375 === 3.3.3 Configure read commands for each sampling === 376 376 377 377 ... ... @@ -609,6 +609,7 @@ 609 609 ))) 610 610 611 611 608 + 612 612 === 3.5.1 Common Commands === 613 613 614 614 ... ... @@ -754,6 +754,7 @@ 754 754 755 755 756 756 754 + 757 757 ==== (% style="color:blue" %)**Set Payload version**(%%) ==== 758 758 759 759 ... ... @@ -796,6 +796,7 @@ 796 796 797 797 798 798 797 + 799 799 ==== (% style="color:blue" %)**Set RS485 Sampling Commands**(%%) ==== 800 800 801 801 ... ... @@ -880,6 +880,7 @@ 880 880 881 881 882 882 882 + 883 883 ==== (% style="color:blue" %)**Fast command to handle MODBUS device**(%%) ==== 884 884 885 885 ... ... @@ -923,6 +923,7 @@ 923 923 924 924 925 925 926 + 926 926 ==== (% style="color:blue" %)**RS485 command timeout**(%%) ==== 927 927 928 928 ... ... @@ -959,7 +959,7 @@ 959 959 ))) 960 960 961 961 ((( 962 -(% style="color:#4472c4" %)** 0x AA aa bb cc**(%%) Same as: AT+CMDDLaa=hex 963 +(% style="color:#4472c4" %)** 0x AA aa bb cc**(%%) Same as: AT+CMDDLaa=hex(bb cc)*1000 963 963 ))) 964 964 965 965 ((( ... ... @@ -969,11 +969,12 @@ 969 969 ))) 970 970 971 971 ((( 972 -**0xAA 01 0 3E8** ~-~-> Same as **AT+CMDDL1=1000 ms**973 +**0xAA 01 00 01** ~-~-> Same as **AT+CMDDL1=1000 ms** 973 973 ))) 974 974 975 975 976 976 978 + 977 977 ==== (% style="color:blue" %)**Uplink payload mode**(%%) ==== 978 978 979 979 ... ... @@ -1028,6 +1028,7 @@ 1028 1028 1029 1029 1030 1030 1033 + 1031 1031 ==== (% style="color:blue" %)**Manually trigger an Uplink**(%%) ==== 1032 1032 1033 1033 ... ... @@ -1057,6 +1057,7 @@ 1057 1057 1058 1058 1059 1059 1063 + 1060 1060 ==== (% style="color:blue" %)**Clear RS485 Command**(%%) ==== 1061 1061 1062 1062 ... ... @@ -1105,6 +1105,7 @@ 1105 1105 1106 1106 1107 1107 1112 + 1108 1108 ==== (% style="color:blue" %)**Set Serial Communication Parameters**(%%) ==== 1109 1109 1110 1110 ... ... @@ -1188,7 +1188,7 @@ 1188 1188 1189 1189 1190 1190 1191 -==== (% style="color:blue" %)**Encrypted payload (Since Version 1.4.0)**(%%) ====1196 +==== (% style="color:blue" %)**Encrypted payload**(%%) ==== 1192 1192 1193 1193 ((( 1194 1194 ... ... @@ -1204,9 +1204,10 @@ 1204 1204 1205 1205 1206 1206 1207 -==== (% style="color:blue" %)**Get sensor value(Since Version 1.4.0)**(%%) ==== 1208 1208 1213 +==== (% style="color:blue" %)**Get sensor value**(%%) ==== 1209 1209 1215 + 1210 1210 * ((( 1211 1211 (% style="color:#037691" %)** AT Command:** 1212 1212 ))) ... ... @@ -1217,9 +1217,10 @@ 1217 1217 1218 1218 1219 1219 1220 -==== (% style="color:blue" %)**Resets the downlink packet count(Since Version 1.4.0)**(%%) ==== 1221 1221 1227 +==== (% style="color:blue" %)**Resets the downlink packet count**(%%) ==== 1222 1222 1229 + 1223 1223 * ((( 1224 1224 (% style="color:#037691" %)** AT Command:** 1225 1225 ))) ... ... @@ -1230,9 +1230,10 @@ 1230 1230 1231 1231 1232 1232 1233 -==== (% style="color:blue" %)**When the limit bytes are exceeded, upload in batches(Since Version 1.4.0)**(%%) ==== 1234 1234 1241 +==== (% style="color:blue" %)**When the limit bytes are exceeded, upload in batches**(%%) ==== 1235 1235 1243 + 1236 1236 * ((( 1237 1237 (% style="color:#037691" %)** AT Command:** 1238 1238 ))) ... ... @@ -1250,9 +1250,10 @@ 1250 1250 1251 1251 1252 1252 1253 -==== (% style="color:blue" %)**Copy downlink to uplink (Since Version 1.4.0)**(%%) ==== 1254 1254 1262 +==== (% style="color:blue" %)** Copy downlink to uplink **(%%) ==== 1255 1255 1264 + 1256 1256 * ((( 1257 1257 (% style="color:#037691" %)** AT Command:** 1258 1258 ))) ... ... @@ -1274,9 +1274,10 @@ 1274 1274 1275 1275 1276 1276 1277 -==== (% style="color:blue" %)**Query version number and frequency band 、TDC(Since Version 1.4.0)**(%%) ==== 1278 1278 1287 +==== (% style="color:blue" %)**Query version number and frequency band 、TDC**(%%) ==== 1279 1279 1289 + 1280 1280 ((( 1281 1281 * (% style="color:#037691" %)**Downlink Payload:** 1282 1282 ... ... @@ -1291,9 +1291,10 @@ 1291 1291 1292 1292 1293 1293 1294 -==== (% style="color:blue" %)** Monitor RS485 communication of other devices(Since Version 1.4.0)**(%%) ==== 1295 1295 1305 +==== (% style="color:blue" %)** Monitor RS485 communication of other devices**(%%) ==== 1296 1296 1307 + 1297 1297 * ((( 1298 1298 (% style="color:#037691" %)** AT Command:** 1299 1299 ))) ... ... @@ -1430,7 +1430,6 @@ 1430 1430 |(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485 1431 1431 |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]] 1432 1432 1433 - 1434 1434 == 3.8 LEDs == 1435 1435 1436 1436 ... ... @@ -1439,7 +1439,6 @@ 1439 1439 |**PWR**|Always on if there is power 1440 1440 |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message. 1441 1441 1442 - 1443 1443 = 4. Case Study = 1444 1444 1445 1445 ... ... @@ -1493,6 +1493,8 @@ 1493 1493 1494 1494 * (% style="color:#037691" %)**AT+NJM=0** 1495 1495 * (% style="color:#037691" %)**ATZ** 1505 + 1506 + 1496 1496 ))) 1497 1497 1498 1498 ... ... @@ -1694,7 +1694,7 @@ 1694 1694 1695 1695 RS485-LN sent below command: 1696 1696 1697 -(% style="color:blue" %)**AT+CFGDEV=01 03 0020 00 01,1**(%%) to RS485 network, and PC is able to get this command and return commands from MTU to show in the serial tool.1708 +(% style="color:blue" %)**AT+CFGDEV=01 03 20 00 01 85 c0,1**(%%) to RS485 network, and PC is able to get this command and return commands from MTU to show in the serial tool. 1698 1698 1699 1699 1700 1700 We can see the output from the Serial port tool to analyze. And check if they are expected result. ... ... @@ -1746,7 +1746,6 @@ 1746 1746 1747 1747 == 6.8 Where to get the decoder for RS485-LN? == 1748 1748 1749 - 1750 1750 The decoder for RS485-LN needs to be written by yourself. Because the sensor to which the user is connected is custom, the read device data bytes also need custom parsing, so there is no universal decoder. We can only provide [[templates>>https://github.com/dragino/dragino-end-node-decoder/tree/main/RS485-LN]] for decoders (no intermediate data parsing part involved) 1751 1751 1752 1752 ... ... @@ -1782,10 +1782,9 @@ 1782 1782 * (% style="color:red" %)**RU864**(%%): frequency bands RU864 1783 1783 * (% style="color:red" %)**KZ865**(%%): frequency bands KZ865 1784 1784 1795 += 9.Packing Info = 1785 1785 1786 -= 9. Packing Info = 1787 1787 1788 - 1789 1789 **Package Includes**: 1790 1790 1791 1791 * RS485-LN x 1 ... ... @@ -1799,7 +1799,6 @@ 1799 1799 * Package Size / pcs : 14.5 x 8 x 5 cm 1800 1800 * Weight / pcs : 170g 1801 1801 1802 - 1803 1803 = 10. FCC Caution for RS485LN-US915 = 1804 1804 1805 1805