<
From version < 101.1 >
edited by Bei Jinggeng
on 2023/04/17 11:59
To version < 102.5 >
edited by Xiaoling
on 2023/04/25 11:00
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.Xiaoling
Content
... ... @@ -94,7 +94,6 @@
94 94  * Automatic RF Sense and CAD with ultra-fast AFC.
95 95  * Packet engine up to 256 bytes with CRC
96 96  
97 -
98 98  == 1.3 Features ==
99 99  
100 100  
... ... @@ -107,7 +107,6 @@
107 107  * Support Modbus protocol
108 108  * Support Interrupt uplink (Since hardware version v1.2)
109 109  
110 -
111 111  == 1.4 Applications ==
112 112  
113 113  
... ... @@ -118,7 +118,6 @@
118 118  * Smart Cities
119 119  * Smart Factory
120 120  
121 -
122 122  == 1.5 Firmware Change log ==
123 123  
124 124  
... ... @@ -285,17 +285,17 @@
285 285  To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
286 286  
287 287  
288 -(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:510px" %)
289 -|=(% style="width: 110px;" %)(((
285 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
286 +|=(% style="width: 119px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)(((
290 290  **AT Commands**
291 -)))|=(% style="width: 210px;" %)(((
288 +)))|=(% style="width: 116px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)(((
292 292  **Description**
293 -)))|=(% style="width: 190px;" %)(((
290 +)))|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)(((
294 294  **Example**
295 295  )))
296 -|(% style="width:110px" %)(((
293 +|(% style="width:119px" %)(((
297 297  AT+BAUDR
298 -)))|(% style="width:190px" %)(((
295 +)))|(% style="width:116px" %)(((
299 299  Set the baud rate (for RS485 connection). Default Value is: 9600.
300 300  )))|(% style="width:190px" %)(((
301 301  (((
... ... @@ -306,9 +306,9 @@
306 306  Options: (1200,2400,4800,14400,19200,115200)
307 307  )))
308 308  )))
309 -|(% style="width:110px" %)(((
306 +|(% style="width:119px" %)(((
310 310  AT+PARITY
311 -)))|(% style="width:190px" %)(((
308 +)))|(% style="width:116px" %)(((
312 312  Set UART parity (for RS485 connection)
313 313  )))|(% style="width:190px" %)(((
314 314  (((
... ... @@ -319,9 +319,9 @@
319 319  Option: 0: no parity, 1: odd parity, 2: even parity
320 320  )))
321 321  )))
322 -|(% style="width:110px" %)(((
319 +|(% style="width:119px" %)(((
323 323  AT+STOPBIT
324 -)))|(% style="width:190px" %)(((
321 +)))|(% style="width:116px" %)(((
325 325  (((
326 326  Set serial stopbit (for RS485 connection)
327 327  )))
... ... @@ -343,7 +343,6 @@
343 343  )))
344 344  )))
345 345  
346 -
347 347  === 3.3.2 Configure sensors ===
348 348  
349 349  
... ... @@ -355,9 +355,9 @@
355 355  )))
356 356  )))
357 357  
358 -(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:510px" %)
359 -|=(% style="width: 110px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 190px;" %)**Example**
360 -|AT+CFGDEV|(% style="width:110px" %)(((
354 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:510px" %)
355 +|=(% style="width: 122px; background-color:#D9E2F3;color:#0070C0" %)**AT Commands**|=(% style="width: 198px; background-color:#D9E2F3;color:#0070C0" %)**Description**|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)**Example**
356 +|(% style="width:122px" %)AT+CFGDEV|(% style="width:196px" %)(((
361 361  (((
362 362  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
363 363  )))
... ... @@ -371,7 +371,6 @@
371 371  )))
372 372  )))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
373 373  
374 -
375 375  === 3.3.3 Configure read commands for each sampling ===
376 376  
377 377  
... ... @@ -402,7 +402,7 @@
402 402  
403 403  (% style="color:#037691" %)**AT+COMMANDx **(%%)**: **This command will be sent to RS485 devices during each sampling, Max command length is 14 bytes. The grammar is:
404 404  
405 -(% border="1" style="background-color:#4bacc6; color:white; width:499px" %)
400 +(% border="1" style="background-color:#f2f2f2; width:499px" %)
406 406  |(% style="width:496px" %)(((
407 407  **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
408 408  
... ... @@ -418,7 +418,7 @@
418 418  
419 419  (% style="color:#037691" %)**AT+DATACUTx **(%%)**: **This command defines how to handle the return from AT+COMMANDx, max return length is 100 bytes.
420 420  
421 -(% border="1" style="background-color:#4bacc6; color:white; width:510px" %)
416 +(% border="1" style="background-color:#f2f2f2; width:510px" %)
422 422  |(% style="width:510px" %)(((
423 423  **AT+DATACUTx=a,b,c**
424 424  
... ... @@ -1430,7 +1430,6 @@
1430 1430  |(% style="width:50px" %)**RST**|(% style="width:361px" %)Reboot RS485
1431 1431  |(% style="width:50px" %)**PRO**|(% style="width:361px" %)Use for upload image, see [[How to Update Image>>||anchor="H6.1Howtoupgradetheimage3F"]]
1432 1432  
1433 -
1434 1434  == 3.8 LEDs ==
1435 1435  
1436 1436  
... ... @@ -1439,7 +1439,6 @@
1439 1439  |**PWR**|Always on if there is power
1440 1440  |**SYS**|After device is powered on, the SYS will (% style="color:green" %)**fast blink in GREEN**(%%) for 5 times, means RS485-LN start to join LoRaWAN network. If join success, SYS will be (% style="color:green" %)**on GREEN for 5 seconds** (%%)**. **SYS will (% style="color:green" %)**blink Blue**(%%) on every upload and (% style="color:green" %)**blink Green**(%%) once receive a downlink message.
1441 1441  
1442 -
1443 1443  = 4. Case Study =
1444 1444  
1445 1445  
... ... @@ -1694,7 +1694,7 @@
1694 1694  
1695 1695  RS485-LN sent below command:
1696 1696  
1697 -(% style="color:blue" %)**AT+CFGDEV=01 03 20 00 01 85 c0,1**(%%) to RS485 network, and PC is able to get this command and return commands from MTU to show in the serial tool.
1690 +(% style="color:blue" %)**AT+CFGDEV=01 03 00 20 00 01,1**(%%) to RS485 network, and PC is able to get this command and return commands from MTU to show in the serial tool.
1698 1698  
1699 1699  
1700 1700  We can see the output from the Serial port tool to analyze. And check if they are expected result.
... ... @@ -1782,7 +1782,6 @@
1782 1782  * (% style="color:red" %)**RU864**(%%):  frequency bands RU864
1783 1783  * (% style="color:red" %)**KZ865**(%%):  frequency bands KZ865
1784 1784  
1785 -
1786 1786  = 9. Packing Info =
1787 1787  
1788 1788  
... ... @@ -1799,7 +1799,6 @@
1799 1799  * Package Size / pcs : 14.5 x 8 x 5 cm
1800 1800  * Weight / pcs : 170g
1801 1801  
1802 -
1803 1803  = 10. FCC Caution for RS485LN-US915 =
1804 1804  
1805 1805  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0