Show last authors
1 (% style="text-align:center" %)
2 [[image:1653266934636-343.png||height="385" width="385"]]
3
4
5
6 **RS485-LN – RS485 to LoRaWAN Converter User Manual**
7
8
9 **Table of Contents:**
10
11
12
13
14
15 = 1.Introduction =
16
17 == 1.1 What is RS485-LN RS485 to LoRaWAN Converter ==
18
19 (((
20 (((
21 The Dragino RS485-LN is a RS485 to LoRaWAN Converter. It converts the RS485 signal into LoRaWAN wireless signal which simplify the IoT installation and reduce the installation/maintaining cost.
22 )))
23
24 (((
25 RS485-LN allows user to monitor / control RS485 devices and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on.
26 )))
27
28 (((
29 For data uplink, RS485-LN sends user-defined commands to RS485 devices and gets the return from the RS485 devices. RS485-LN will process these returns according to user-define rules to get the final payload and upload to LoRaWAN server.
30 )))
31
32 (((
33 For data downlink, RS485-LN runs in LoRaWAN Class C. When there downlink commands from LoRaWAN server, RS485-LN will forward the commands from LoRaWAN server to RS485 devices.
34 )))
35 )))
36
37 [[image:1653267211009-519.png||height="419" width="724"]]
38
39 == 1.2 Specifications ==
40
41 **Hardware System:**
42
43 * STM32L072CZT6 MCU
44 * SX1276/78 Wireless Chip 
45 * Power Consumption (exclude RS485 device):
46 ** Idle: 32mA@12v
47
48 *
49 ** 20dB Transmit: 65mA@12v
50
51 **Interface for Model:**
52
53 * RS485
54 * Power Input 7~~ 24V DC. 
55
56 **LoRa Spec:**
57
58 * Frequency Range:
59 ** Band 1 (HF): 862 ~~ 1020 Mhz
60 ** Band 2 (LF): 410 ~~ 528 Mhz
61 * 168 dB maximum link budget.
62 * +20 dBm - 100 mW constant RF output vs.
63 * +14 dBm high efficiency PA.
64 * Programmable bit rate up to 300 kbps.
65 * High sensitivity: down to -148 dBm.
66 * Bullet-proof front end: IIP3 = -12.5 dBm.
67 * Excellent blocking immunity.
68 * Low RX current of 10.3 mA, 200 nA register retention.
69 * Fully integrated synthesizer with a resolution of 61 Hz.
70 * FSK, GFSK, MSK, GMSK, LoRaTM and OOK modulation.
71 * Built-in bit synchronizer for clock recovery.
72 * Preamble detection.
73 * 127 dB Dynamic Range RSSI.
74 * Automatic RF Sense and CAD with ultra-fast AFC.
75 * Packet engine up to 256 bytes with CRC.
76
77 == 1.3 Features ==
78
79 * LoRaWAN Class A & Class C protocol (default Class C)
80 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865/RU864
81 * AT Commands to change parameters
82 * Remote configure parameters via LoRa Downlink
83 * Firmware upgradable via program port
84 * Support multiply RS485 devices by flexible rules
85 * Support Modbus protocol
86 * Support Interrupt uplink (Since hardware version v1.2)
87
88 == 1.4 Applications ==
89
90 * Smart Buildings & Home Automation
91 * Logistics and Supply Chain Management
92 * Smart Metering
93 * Smart Agriculture
94 * Smart Cities
95 * Smart Factory
96
97 == 1.5 Firmware Change log ==
98
99 [[RS485-LN Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/]]
100
101 == 1.6 Hardware Change log ==
102
103 (((
104 (((
105 v1.2: Add External Interrupt Pin.
106
107 v1.0: Release
108 )))
109 )))
110
111 = 2. Power ON Device =
112
113 (((
114 The RS485-LN can be powered by 7 ~~ 24V DC power source. Connection as below
115
116 * Power Source VIN to RS485-LN VIN+
117 * Power Source GND to RS485-LN VIN-
118
119 (((
120 Once there is power, the RS485-LN will be on.
121 )))
122
123 [[image:1653268091319-405.png]]
124 )))
125
126 = 3. Operation Mode =
127
128 == 3.1 How it works? ==
129
130 (((
131 The RS485-LN is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the RS485-LN. It will auto join the network via OTAA.
132 )))
133
134 == 3.2 Example to join LoRaWAN network ==
135
136 Here shows an example for how to join the TTN V3 Network. Below is the network structure, we use [[LG308>>url:http://www.dragino.com/products/lora-lorawan-gateway/item/140-lg308.html]] as LoRaWAN gateway here. 
137
138 [[image:1653268155545-638.png||height="334" width="724"]]
139
140 (((
141 The RS485-LN in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method. The connection is as below:
142
143 485A+ and 485B- of the sensor are connected to RS485A and RA485B of RS485-LN respectively.
144
145 [[image:1653268227651-549.png||height="592" width="720"]]
146
147 (((
148 The LG308 is already set to connect to [[TTN V3 network >>path:eu1.cloud.thethings.network/]]. So what we need to now is only configure the TTN V3:
149 )))
150
151 (((
152 **Step 1**: Create a device in TTN V3 with the OTAA keys from RS485-LN.
153 )))
154
155 (((
156 Each RS485-LN is shipped with a sticker with unique device EUI:
157 )))
158 )))
159
160 [[image:1652953462722-299.png]]
161
162 (((
163 (((
164 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot:
165 )))
166
167 (((
168 Add APP EUI in the application.
169 )))
170 )))
171
172 [[image:image-20220519174512-1.png]]
173
174 [[image:image-20220519174512-2.png||height="323" width="720"]]
175
176 [[image:image-20220519174512-3.png||height="556" width="724"]]
177
178 [[image:image-20220519174512-4.png]]
179
180 You can also choose to create the device manually.
181
182 [[image:1652953542269-423.png||height="710" width="723"]]
183
184 Add APP KEY and DEV EUI
185
186 [[image:1652953553383-907.png||height="514" width="724"]]
187
188
189 (((
190 **Step 2**: Power on RS485-LN and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
191 )))
192
193 [[image:1652953568895-172.png||height="232" width="724"]]
194
195 == 3.3 Configure Commands to read data ==
196
197 (((
198 (((
199 There are plenty of RS485 devices in the market and each device has different command to read the valid data. To support these devices in flexible, RS485-LN supports flexible command set. User can use [[AT Commands>>path:#AT_COMMAND]] or LoRaWAN Downlink Command to configure what commands RS485-LN should send for each sampling and how to handle the return from RS485 devices.
200 )))
201
202 (((
203 (% style="color:red" %)Note: below description and commands are for firmware version >v1.1, if you have firmware version v1.0. Please check the [[user manual v1.0>>url:http://www.dragino.com/downloads/index.php?dir=RS485-LN/&file=RS485-LN_UserManual_v1.0.1.pdf]] or upgrade the firmware to v1.1
204 )))
205 )))
206
207 === 3.3.1 onfigure UART settings for RS485 or TTL communication ===
208
209 To use RS485-LN to read data from RS485 sensors, connect the RS485-LN A/B traces to the sensors. And user need to make sure RS485-LN use the match UART setting to access the sensors. The related commands for UART settings are:
210
211 (% border="1" style="background-color:#ffffcc; color:green; width:795px" %)
212 |(((
213 **AT Commands**
214 )))|(% style="width:285px" %)(((
215 **Description**
216 )))|(% style="width:347px" %)(((
217 **Example**
218 )))
219 |(((
220 AT+BAUDR
221 )))|(% style="width:285px" %)(((
222 Set the baud rate (for RS485 connection). Default Value is: 9600.
223 )))|(% style="width:347px" %)(((
224 (((
225 AT+BAUDR=9600
226 )))
227
228 (((
229 Options: (1200,2400,4800,14400,19200,115200)
230 )))
231 )))
232 |(((
233 AT+PARITY
234 )))|(% style="width:285px" %)(((
235 Set UART parity (for RS485 connection)
236 )))|(% style="width:347px" %)(((
237 (((
238 AT+PARITY=0
239 )))
240
241 (((
242 Option: 0: no parity, 1: odd parity, 2: even parity
243 )))
244 )))
245 |(((
246 AT+STOPBIT
247 )))|(% style="width:285px" %)(((
248 (((
249 Set serial stopbit (for RS485 connection)
250 )))
251
252 (((
253
254 )))
255 )))|(% style="width:347px" %)(((
256 (((
257 AT+STOPBIT=0 for 1bit
258 )))
259
260 (((
261 AT+STOPBIT=1 for 1.5 bit
262 )))
263
264 (((
265 AT+STOPBIT=2 for 2 bits
266 )))
267 )))
268
269 === 3.3.2 Configure sensors ===
270
271 (((
272 (((
273 Some sensors might need to configure before normal operation. User can configure such sensor via PC and RS485 adapter or through RS485-LN AT Commands (% style="color:#4f81bd" %)**AT+CFGDEV**(%%). Each (% style="color:#4f81bd" %)**AT+CFGDEV **(%%)equals to send a RS485 command to sensors. This command will only run when user input it and won’t run during each sampling.
274 )))
275 )))
276
277 (% border="1" style="background-color:#ffffcc; color:green; width:806px" %)
278 |**AT Commands**|(% style="width:418px" %)**Description**|(% style="width:256px" %)**Example**
279 |AT+CFGDEV|(% style="width:418px" %)(((
280 This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
281
282 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
283
284 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
285 )))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
286
287 === 3.3.3 Configure read commands for each sampling ===
288
289 (((
290 RS485-BL is a battery powered device; it will sleep most of time. And wake up on each period and read RS485 / TTL sensor data and uplink.
291 )))
292
293 (((
294 During each sampling, we need to confirm what commands we need to send to the sensors to read data. After the RS485/TTL sensors send back the value, it normally includes some bytes and we only need a few from them for a shorten payload.
295 )))
296
297 (((
298 To save the LoRaWAN network bandwidth, we might need to read data from different sensors and combine their valid value into a short payload.
299 )))
300
301 (((
302 This section describes how to achieve above goals.
303 )))
304
305 (((
306 During each sampling, the RS485-BL can support 15 commands to read sensors. And combine the return to one or several uplink payloads.
307 )))
308
309 (((
310 **Command from RS485-BL to Sensor:**
311 )))
312
313 (((
314 RS485-BL can send out pre-set max 15 strings via **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF** . All commands are of same grammar.
315 )))
316
317 (((
318 **Handle return from sensors to RS485-BL**:
319 )))
320
321 (((
322 After RS485-BL send out a string to sensor, RS485-BL will wait for the return from RS485 or TTL sensor. And user can specify how to handle the return, by **AT+DATACUT or AT+SEARCH commands**
323 )))
324
325 * (((
326 **AT+DATACUT**
327 )))
328
329 (((
330 When the return value from sensor have fix length and we know which position the valid value we should get, we can use AT+DATACUT command.
331 )))
332
333 * (((
334 **AT+SEARCH**
335 )))
336
337 (((
338 When the return value from sensor is dynamic length and we are not sure which bytes the valid data is, instead, we know what value the valid value following. We can use AT+SEARCH to search the valid value in the return string.
339 )))
340
341 (((
342 **Define wait timeout:**
343 )))
344
345 (((
346 Some RS485 device might has longer delay on reply, so user can use AT+CMDDL to set the timeout for getting reply after the RS485 command is sent. For example, AT+CMDDL1=1000 to send the open time to 1000ms
347 )))
348
349 (((
350 After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**.
351 )))
352
353 **Examples:**
354
355 Below are examples for the how above AT Commands works.
356
357 **AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is:
358
359 (% border="1" class="table-bordered" %)
360 |(((
361 **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
362
363 **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent**
364
365 **m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command**
366 )))
367
368 (((
369 For example, if we have a RS485 sensor. The command to get sensor value is: 01 03 0B B8 00 02 46 0A. Where 01 03 0B B8 00 02 is the Modbus command to read the register 0B B8 where stored the sensor value. The 46 0A is the CRC-16/MODBUS which calculate manually.
370 )))
371
372 (((
373 In the RS485-BL, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same.
374 )))
375
376 (((
377 **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx.
378 )))
379
380 (% border="1" class="table-bordered" %)
381 |(((
382 **AT+SEARCHx=aa,xx xx xx xx xx**
383
384 * **aa: 1: prefix match mode; 2: prefix and suffix match mode**
385 * **xx xx xx xx xx: match string. Max 5 bytes for prefix and 5 bytes for suffix**
386
387
388 )))
389
390 **Examples:**
391
392 ~1. For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
393
394 If we set AT+SEARCH1=1,1E 56 34.      (max 5 bytes for prefix)
395
396 The valid data will be all bytes after 1E 56 34 , so it is (% style="background-color:yellow" %)** 2e 30 58 5f 36 41 30 31 00 49**
397
398 [[image:1653269403619-508.png]]
399
400 2. For a return string from AT+COMMAND1:  16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
401
402 If we set AT+SEARCH1=2, 1E 56 34+31 00 49
403
404 Device will search the bytes between 1E 56 34 and 31 00 49. So it is (% style="background-color:yellow" %)** 2e 30 58 5f 36 41 30**
405
406 [[image:1653269438444-278.png]]
407
408 **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
409
410 |(((
411 **AT+DATACUTx=a,b,c**
412
413 * **a: length for the return of AT+COMMAND**
414 * **b:1: grab valid value by byte, max 6 bytes. 2: grab valid value by bytes section, max 3 sections.**
415 * **c: define the position for valid value.  **
416 )))
417
418 Examples:
419
420 * Grab bytes:
421
422 [[image:1653269551753-223.png||height="311" width="717"]]
423
424 * Grab a section.
425
426 [[image:1653269568276-930.png||height="325" width="718"]]
427
428 * Grab different sections.
429
430 [[image:1653269593172-426.png||height="303" width="725"]]
431
432 (% style="color:red" %)**Note:**
433
434 AT+SEARCHx and AT+DATACUTx can be used together, if both commands are set, RS485-BL will first process AT+SEARCHx on the return string and get a temporary string, and then process AT+DATACUTx on this temporary string to get the final payload. In this case, AT+DATACUTx need to set to format AT+DATACUTx=0,xx,xx where the return bytes set to 0.
435
436 Example:
437
438 (% style="color:red" %)AT+COMMAND1=11 01 1E D0,0
439
440 (% style="color:red" %)AT+SEARCH1=1,1E 56 34
441
442 (% style="color:red" %)AT+DATACUT1=0,2,1~~5
443
444 (% style="color:red" %)Return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49
445
446 (% style="color:red" %)String after SEARCH command: 2e 30 58 5f 36 41 30 31 00 49
447
448 (% style="color:red" %)Valid payload after DataCUT command: 2e 30 58 5f 36
449
450 [[image:1653269618463-608.png]]
451
452 === 3.3.4 Compose the uplink payload ===
453
454 (((
455 Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.**
456 )))
457
458 (((
459 (% style="color:#4f81bd" %)**Examples: AT+DATAUP=0**
460 )))
461
462 (((
463 Compose the uplink payload with value returns in sequence and send with (% style="color:red" %)**A SIGNLE UPLINK**.
464 )))
465
466 (((
467 Final Payload is
468 )))
469
470 (((
471 (% style="color:#4f81bd" %)**Battery Info+PAYVER + VALID Value from RETURN1 + Valid Value from RETURN2 + … + RETURNx**
472 )))
473
474 (((
475 Where PAYVER is defined by AT+PAYVER, below is an example screen shot.
476 )))
477
478 [[image:1653269759169-150.png]]
479
480
481
482 **Examples: AT+DATAUP=1**
483
484 Compose the uplink payload with value returns in sequence and send with **Multiply UPLINKs**.
485
486 Final Payload is
487
488 Battery Info+PAYVER + PAYLOAD COUNT + PAYLOAD# + DATA
489
490 1. Battery Info (2 bytes): Battery voltage
491 1. PAYVER (1 byte): Defined by AT+PAYVER
492 1. PAYLOAD COUNT (1 byte): Total how many uplinks of this sampling.
493 1. PAYLOAD# (1 byte): Number of this uplink. (from 0,1,2,3…,to PAYLOAD COUNT)
494 1. DATA: Valid value: max 6 bytes(US915 version here, [[Notice*!>>path:#max_byte]]) for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 6 bytes
495
496 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image020.png]]
497
498
499 So totally there will be 3 uplinks for this sampling, each uplink includes 6 bytes DATA
500
501 DATA1=RETURN1 Valid Value = 20 20 0a 33 90 41
502
503 DATA2=1^^st^^ ~~ 6^^th^^ byte of Valid value of RETURN10= 02 aa 05 81 0a 20
504
505 DATA3=7^^th^^ ~~ 11^^th^^ bytes of Valid value of RETURN10 = 20 20 20 2d 30
506
507
508
509 Below are the uplink payloads:
510
511 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image021.png]]
512
513
514 Notice: the Max bytes is according to the max support bytes in different Frequency Bands for lowest SF. As below:
515
516 ~* For AU915/AS923 bands, if UplinkDwell time=0, max 51 bytes for each uplink ( so 51 -5 = 46 max valid date)
517
518 * For AU915/AS923 bands, if UplinkDwell time=1, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date).
519
520 * For US915 band, max 11 bytes for each uplink ( so 11 -5 = 6 max valid date).
521
522 ~* For all other bands: max 51 bytes for each uplink  ( so 51 -5 = 46 max valid date).
523
524
525
526 1.
527 11.
528 111. Uplink on demand
529
530 Except uplink periodically, RS485-BL is able to uplink on demand. The server sends downlink command to RS485-BL and RS485 will uplink data base on the command.
531
532 Downlink control command:
533
534 [[0x08 command>>path:#downlink_08]]: Poll an uplink with current command set in RS485-BL.
535
536 [[0xA8 command>>path:#downlink_A8]]: Send a command to RS485-BL and uplink the output from sensors.
537
538
539
540 1.
541 11.
542 111. Uplink on Interrupt
543
544 Put the interrupt sensor between 3.3v_out and GPIO ext.[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]
545
546 AT+INTMOD=0  Disable Interrupt
547
548 AT+INTMOD=1  Interrupt trigger by rising or falling edge.
549
550 AT+INTMOD=2  Interrupt trigger by falling edge. ( Default Value)
551
552 AT+INTMOD=3  Interrupt trigger by rising edge.
553
554
555 1.
556 11. Uplink Payload
557
558 |**Size(bytes)**|**2**|**1**|**Length depends on the return from the commands**
559 |Value|(((
560 Battery(mV)
561
562 &
563
564 Interrupt _Flag
565 )))|(((
566 PAYLOAD_VER
567
568
569 )))|If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server.
570
571 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors.
572
573
574 function Decoder(bytes, port) {
575
576 ~/~/Payload Formats of RS485-BL Deceive
577
578 return {
579
580 ~/~/Battery,units:V
581
582 BatV:((bytes[0]<<8 | bytes[1])&0x7fff)/1000,
583
584 ~/~/GPIO_EXTI 
585
586 EXTI_Trigger:(bytes[0] & 0x80)? "TRUE":"FALSE",
587
588 ~/~/payload of version
589
590 Pay_ver:bytes[2],
591
592 };
593
594 }
595
596
597
598
599
600
601
602 TTN V3 uplink screen shot.
603
604 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
605
606 1.
607 11. Configure RS485-BL via AT or Downlink
608
609 User can configure RS485-BL via [[AT Commands >>path:#_​Using_the_AT]]or LoRaWAN Downlink Commands
610
611 There are two kinds of Commands:
612
613 * **Common Commands**: They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: http:~/~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands
614
615 * **Sensor Related Commands**: These commands are special designed for RS485-BL.  User can see these commands below:
616
617 1.
618 11.
619 111. Common Commands:
620
621 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands]]
622
623
624 1.
625 11.
626 111. Sensor related commands:
627
628 ==== Choose Device Type (RS485 or TTL) ====
629
630 RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect.
631
632 * AT Command
633
634 **AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins.
635
636 **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins.
637
638
639 * Downlink Payload
640
641 **0A aa**     à same as AT+MOD=aa
642
643
644
645 ==== [[RS485 Debug Command>>path:#downlink_A8]] (AT+CFGDEV) ====
646
647 This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling.
648
649 * AT Command
650
651 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
652
653 m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command.
654
655
656
657 * Downlink Payload
658
659 Format: A8 MM NN XX XX XX XX YY
660
661 Where:
662
663 * MM: 1: add CRC-16/MODBUS ; 0: no CRC
664 * NN: The length of RS485 command
665 * XX XX XX XX: RS485 command total NN bytes
666 * YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command
667
668 **Example 1:**
669
670 To connect a Modbus Alarm with below commands.
671
672 * The command to active alarm is: 0A 05 00 04 00 01 4C B0. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
673
674 * The command to deactivate alarm is: 0A 05 00 04 00 00 8D 70. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
675
676 So if user want to use downlink command to control to RS485 Alarm, he can use:
677
678 **A8 01 06 0A 05 00 04 00 01 00**: to activate the RS485 Alarm
679
680 **A8 01 06 0A 05 00 04 00 00 00**: to deactivate the RS485 Alarm
681
682 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output.
683
684
685 **Example 2:**
686
687 Check TTL Sensor return:
688
689 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]
690
691
692
693
694 ==== Set Payload version ====
695
696 This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
697
698 * AT Command:
699
700 AT+PAYVER: Set PAYVER field = 1
701
702
703 * Downlink Payload:
704
705 0xAE 01   à Set PAYVER field =  0x01
706
707 0xAE 0F   à Set PAYVER field =  0x0F
708
709
710 ==== Set RS485 Sampling Commands ====
711
712 AT+COMMANDx, AT+DATACUTx and AT+SEARCHx
713
714 These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>path:#polling_485]].
715
716
717 * AT Command:
718
719 AT+COMMANDx: Configure RS485 read command to sensor.
720
721 AT+DATACUTx: Configure how to handle return from RS485 devices.
722
723 AT+SEARCHx: Configure search command
724
725
726 * Downlink Payload:
727
728 0xAF downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
729
730 Note: if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
731
732 Format: AF MM NN LL XX XX XX XX YY
733
734 Where:
735
736 * MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
737 * NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
738 * LL: The length of AT+COMMAND or AT+DATACUT command
739 * XX XX XX XX: AT+COMMAND or AT+DATACUT command
740 * YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command.
741
742 Example:
743
744 **AF 03 01 06 0A 05 00 04 00 01 00**: Same as AT+COMMAND3=0A 05 00 04 00 01,1
745
746 **AF 03 02 06 10 01 05 06 09 0A 00**: Same as AT+DATACUT3=**16**,**1**,**5+6+9+10**
747
748 **AF 03 02 06 0B 02 05 07 08 0A 00**: Same as AT+DATACUT3=**11**,**2**,**5~~7+8~~10**
749
750
751 0xAB downlink command can be used for set AT+SEARCHx
752
753 Example: **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So
754
755 * AB aa 01 03 xx xx xx  same as AT+SEARCHaa=1,xx xx xx
756 * AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands
757
758 **AB aa 02 03 xx xx xx 02 yy yy**  same as **AT+SEARCHaa=2,xx xx xx+yy yy**
759
760
761 ==== Fast command to handle MODBUS device ====
762
763 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
764
765 This command is valid since v1.3 firmware version
766
767
768 AT+MBFUN has only two value:
769
770 * AT+MBFUN=1: Enable Modbus reading. And get response base on the MODBUS return
771
772 AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore.
773
774 * AT+MBFUN=0: Disable Modbus fast reading.
775
776 Example:
777
778 * AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0).
779 * AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
780 * AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
781
782 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]
783
784
785 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]
786
787
788 * Downlink Commands:
789
790 A9 aa -à Same as AT+MBFUN=aa
791
792
793 ==== RS485 command timeout ====
794
795 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action.
796
797 Default value: 0, range:  0 ~~ 5 seconds
798
799
800 * AT Command:
801
802 AT+CMDDLaa=hex(bb cc)
803
804 Example:
805
806 **AT+CMDDL1=1000** to send the open time to 1000ms
807
808
809 * Downlink Payload:
810
811 0x AA aa bb cc
812
813 Same as: AT+CMDDLaa=hex(bb cc)
814
815 Example:
816
817 0xAA 01 03 E8  à Same as **AT+CMDDL1=1000 ms**
818
819
820 ==== [[Uplink>>path:#downlink_A8]] payload mode ====
821
822 Define to use one uplink or multiple uplinks for the sampling.
823
824 The use of this command please see: [[Compose Uplink payload>>path:#DataUP]]
825
826 * AT Command:
827
828 AT+DATAUP=0
829
830 AT+DATAUP=1
831
832
833 * Downlink Payload:
834
835 0xAD 00   à Same as AT+DATAUP=0
836
837 0xAD 01   à Same as AT+DATAUP=1
838
839
840 ==== Manually trigger an Uplink ====
841
842 Ask device to send an uplink immediately.
843
844 * Downlink Payload:
845
846 0x08 FF, RS485-BL will immediately send an uplink.
847
848
849 ==== Clear RS485 Command ====
850
851 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
852
853
854 * AT Command:
855
856 **AT+CMDEAR=mm,nn**   mm: start position of erase ,nn: stop position of erase
857
858 Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
859
860 Example screen shot after clear all RS485 commands. 
861
862
863
864 The uplink screen shot is:
865
866 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]
867
868
869 * Downlink Payload:
870
871 0x09 aa bb same as AT+CMDEAR=aa,bb
872
873
874 ==== Set Serial Communication Parameters ====
875
876 Set the Rs485 serial communication parameters:
877
878 * AT Command:
879
880 Set Baud Rate:
881
882 AT+BAUDR=9600    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
883
884
885 Set UART parity
886
887 AT+PARITY=0    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
888
889
890 Set STOPBIT
891
892 AT+STOPBIT=0    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
893
894
895 * Downlink Payload:
896
897 A7 01 aa bb: Same  AT+BAUDR=hex(aa bb)*100
898
899 Example:
900
901 * A7 01 00 60   same as AT+BAUDR=9600
902 * A7 01 04 80  same as AT+BAUDR=115200
903
904 A7 02 aa: Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
905
906 A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
907
908
909 ==== Control output power duration ====
910
911 User can set the output power duration before each sampling.
912
913 * AT Command:
914
915 Example:
916
917 AT+3V3T=1000 ~/~/ 3V3 output power will open 1s before each sampling.
918
919 AT+5VT=1000 ~/~/ +5V output power will open 1s before each sampling.
920
921
922 * LoRaWAN Downlink Command:
923
924 07 01 aa bb  Same as AT+5VT=(aa bb)
925
926 07 02 aa bb  Same as AT+3V3T=(aa bb)
927
928
929
930
931 1.
932 11. Buttons
933
934 |**Button**|**Feature**
935 |**RST**|Reboot RS485-BL
936
937 1.
938 11. +3V3 Output
939
940 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
941
942 The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 
943
944
945 The +3V3 output time can be controlled by AT Command.
946
947 **AT+3V3T=1000**
948
949 Means set +3v3 valid time to have 1000ms. So, the real +3v3 output will actually have 1000ms + sampling time for other sensors.
950
951
952 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
953
954
955 1.
956 11. +5V Output
957
958 RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
959
960 The +5V output will be valid for every sampling. RS485-BL will enable +5V output before all sampling and disable the +5v after all sampling. 
961
962
963 The 5V output time can be controlled by AT Command.
964
965 **AT+5VT=1000**
966
967 Means set 5V valid time to have 1000ms. So, the real 5V output will actually have 1000ms + sampling time for other sensors.
968
969
970 By default, the AT+5VT=0. If the external sensor which require 5v and require more time to get stable state, user can use this command to increase the power ON duration for this sensor.
971
972
973
974
975 1.
976 11. LEDs
977
978 |**LEDs**|**Feature**
979 |**LED1**|Blink when device transmit a packet.
980
981 1.
982 11. Switch Jumper
983
984 |**Switch Jumper**|**Feature**
985 |**SW1**|(((
986 ISP position: Upgrade firmware via UART
987
988 Flash position: Configure device, check running status.
989 )))
990 |**SW2**|(((
991 5V position: set to compatible with 5v I/O.
992
993 3.3v position: set to compatible with 3.3v I/O.,
994 )))
995
996 +3.3V: is always ON
997
998 +5V: Only open before every sampling. The time is by default, it is AT+5VT=0.  Max open time. 5000 ms.
999
1000 1. Case Study
1001
1002 User can check this URL for some case studies.
1003
1004 [[http:~~/~~/wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS>>url:http://wiki.dragino.com/index.php?title=APP_RS485_COMMUNICATE_WITH_SENSORS]]
1005
1006
1007
1008
1009 1. Use AT Command
1010 11. Access AT Command
1011
1012 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below.
1013
1014 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image027.png]]
1015
1016
1017 In PC, User needs to set **serial tool**(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to **9600** to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference:
1018
1019 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image028.png]]
1020
1021
1022
1023 More detail AT Command manual can be found at [[AT Command Manual>>path:#AT_COMMAND]]
1024
1025
1026
1027 1.
1028 11. Common AT Command Sequence
1029 111. Multi-channel ABP mode (Use with SX1301/LG308)
1030
1031 If device has not joined network yet:
1032
1033 AT+FDR
1034
1035 AT+NJM=0
1036
1037 ATZ
1038
1039
1040 If device already joined network:
1041
1042 AT+NJM=0
1043
1044 ATZ
1045
1046 1.
1047 11.
1048 111. Single-channel ABP mode (Use with LG01/LG02)
1049
1050 AT+FDR   Reset Parameters to Factory Default, Keys Reserve
1051
1052 AT+NJM=0 Set to ABP mode
1053
1054 AT+ADR=0 Set the Adaptive Data Rate Off
1055
1056 AT+DR=5  Set Data Rate
1057
1058 AT+TDC=60000  Set transmit interval to 60 seconds
1059
1060 AT+CHS=868400000 Set transmit frequency to 868.4Mhz
1061
1062 AT+RX2FQ=868400000 Set RX2Frequency to 868.4Mhz (according to the result from server)
1063
1064 AT+RX2DR=5  Set RX2DR to match the downlink DR from server. see below
1065
1066 AT+DADDR=26 01 1A F1 Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.
1067
1068 ATZ          Reset MCU
1069
1070 **Note:**
1071
1072 1. Make sure the device is set to ABP mode in the IoT Server.
1073 1. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1074 1. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1075 1. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1076
1077 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image029.png]]
1078
1079
1080 1. FAQ
1081 11. How to upgrade the image?
1082
1083 The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to:
1084
1085 * Support new features
1086 * For bug fix
1087 * Change LoRaWAN bands.
1088
1089 Below shows the hardware connection for how to upload an image to RS485-BL:
1090
1091 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image030.png]]
1092
1093 **Step1:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1094
1095 **Step2**: Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1096
1097 **Step3: **Open flashloader; choose the correct COM port to update.
1098
1099
1100 |(((
1101 HOLD PRO then press the RST button, SYS will be ON, then click next
1102 )))
1103
1104 |(((
1105 Board detected
1106 )))
1107
1108 |(((
1109
1110 )))
1111
1112 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image031.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image032.png]]
1113
1114
1115
1116 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image033.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image034.png]]
1117
1118
1119 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image035.png]] [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image036.png]]
1120
1121
1122 1.
1123 11. How to change the LoRa Frequency Bands/Region?
1124
1125 User can follow the introduction for [[how to upgrade image>>path:#upgrade_image]]. When download the images, choose the required image file for download.
1126
1127
1128
1129 1.
1130 11. How many RS485-Slave can RS485-BL connects?
1131
1132 The RS485-BL can support max 32 RS485 devices. Each uplink command of RS485-BL can support max 16 different RS485 command. So RS485-BL can support max 16 RS485 devices pre-program in the device for uplink. For other devices no pre-program, user can use the [[downlink message (type code 0xA8) to poll their info>>path:#downlink_A8]].
1133
1134
1135
1136
1137 1. Trouble Shooting     
1138 11. Downlink doesn’t work, how to solve it?
1139
1140 Please see this link for debug:
1141
1142 [[http:~~/~~/wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug>>url:http://wiki.dragino.com/index.php?title=Main_Page#LoRaWAN_Communication_Debug]] 
1143
1144
1145
1146 1.
1147 11. Why I can’t join TTN V3 in US915 /AU915 bands?
1148
1149 It might about the channels mapping. Please see for detail.
1150
1151 [[http:~~/~~/wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band>>url:http://wiki.dragino.com/index.php?title=LoRaWAN_Communication_Debug#Notice_of_US915.2FCN470.2FAU915_Frequency_band]]
1152
1153
1154
1155 1. Order Info
1156
1157 **Part Number: RS485-BL-XXX**
1158
1159 **XXX:**
1160
1161 * **EU433**: frequency bands EU433
1162 * **EU868**: frequency bands EU868
1163 * **KR920**: frequency bands KR920
1164 * **CN470**: frequency bands CN470
1165 * **AS923**: frequency bands AS923
1166 * **AU915**: frequency bands AU915
1167 * **US915**: frequency bands US915
1168 * **IN865**: frequency bands IN865
1169 * **RU864**: frequency bands RU864
1170 * **KZ865: **frequency bands KZ865
1171
1172 1. Packing Info
1173
1174 **Package Includes**:
1175
1176 * RS485-BL x 1
1177 * Stick Antenna for LoRa RF part x 1
1178 * Program cable x 1
1179
1180 **Dimension and weight**:
1181
1182 * Device Size: 13.5 x 7 x 3 cm
1183 * Device Weight: 105g
1184 * Package Size / pcs : 14.5 x 8 x 5 cm
1185 * Weight / pcs : 170g
1186
1187 1. Support
1188
1189 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1190 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to
1191
1192 [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]