Version 45.4 by Xiaoling on 2023/02/21 15:29

Show last authors
1 [[image:image-20230131115217-1.png]]
2
3
4
5 **Table of Contents:**
6
7 {{toc/}}
8
9
10
11
12
13
14 = 1. Introduction =
15
16 == 1.1 What is LoRaWAN Pressure Sensor ==
17
18
19 (((
20 The Dragino PS-LB series sensors are (% style="color:blue" %)**LoRaWAN Pressure Sensor**(%%) for Internet of Things solution. PS-LB can measure Air, Water pressure and liquid level and upload the sensor data via wireless to LoRaWAN IoT server.
21 )))
22
23 (((
24 The PS-LB series sensors include (% style="color:blue" %)**Thread Installation Type**(%%) and (% style="color:blue" %)**Immersion Type**(%%), it supports different pressure range which can be used for different measurement requirement.
25 )))
26
27 (((
28 The LoRa wireless technology used in PS-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
29 )))
30
31 (((
32 PS-LB supports BLE configure and wireless OTA update which make user easy to use.
33 )))
34
35 (((
36 PS-LB is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), it is designed for long term use up to 5 years.
37 )))
38
39 (((
40 Each PS-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
41 )))
42
43 [[image:1675071321348-194.png]]
44
45
46 == 1.2 ​Features ==
47
48
49 * LoRaWAN 1.0.3 Class A
50 * Ultra-low power consumption
51 * Measure air / gas or water pressure
52 * Different pressure range available
53 * Thread Installation Type or Immersion Type
54 * Monitor Battery Level
55 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865
56 * Support Bluetooth v5.1 and LoRaWAN remote configure
57 * Support wireless OTA update firmware
58 * Uplink on periodically
59 * Downlink to change configure
60 * 8500mAh Battery for long term use
61
62
63
64 == 1.3 Specification ==
65
66
67 (% style="color:#037691" %)**Micro Controller:**
68
69 * MCU: 48Mhz ARM
70 * Flash: 256KB
71 * RAM: 64KB
72
73 (% style="color:#037691" %)**Common DC Characteristics:**
74
75 * Supply Voltage: 2.5v ~~ 3.6v
76 * Operating Temperature: -40 ~~ 85°C
77
78 (% style="color:#037691" %)**LoRa Spec:**
79
80 * Frequency Range,  Band 1 (HF): 862 ~~ 1020 Mhz
81 * Max +22 dBm constant RF output vs.
82 * RX sensitivity: down to -139 dBm.
83 * Excellent blocking immunity
84
85 (% style="color:#037691" %)**Current Input Measuring :**
86
87 * Range: 0 ~~ 20mA
88 * Accuracy: 0.02mA
89 * Resolution: 0.001mA
90
91 (% style="color:#037691" %)**Voltage Input Measuring:**
92
93 * Range: 0 ~~ 30v
94 * Accuracy: 0.02v
95 * Resolution: 0.001v
96
97 (% style="color:#037691" %)**Battery:**
98
99 * Li/SOCI2 un-chargeable battery
100 * Capacity: 8500mAh
101 * Self-Discharge: <1% / Year @ 25°C
102 * Max continuously current: 130mA
103 * Max boost current: 2A, 1 second
104
105 (% style="color:#037691" %)**Power Consumption**
106
107 * Sleep Mode: 5uA @ 3.3v
108 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
109
110
111
112 == 1.4 Probe Types ==
113
114 === 1.4.1 Thread Installation Type ===
115
116
117 [[image:1675071448299-229.png]]
118
119 * Hersman Pressure Transmitter
120 * Measuring Range: -0.1 ~~ 0 ~~ 60MPa, see order info.
121 * Accuracy: 0.2% F.S
122 * Long-Term Stability: 0.2% F.S ±0.05%
123 * Overload 200% F.S
124 * Zero Temperature Drift: 0.03% FS/℃(≤100Kpa), 0.02%FS/℃(>100Kpa)
125 * FS Temperature Drift: 0.003% FS/℃(≤100Kpa), 0.002%FS/℃(>100Kpa)
126 * Storage temperature: -30℃~~80℃
127 * Operating temperature: -20℃~~60℃
128 * Connector Type: Various Types, see order info
129
130
131
132 === 1.4.2 Immersion Type ===
133
134
135 [[image:1675071521308-426.png]]
136
137 * Immersion Type, Probe IP Level: IP68
138 * Measuring Range: Measure range can be customized, up to 100m.
139 * Accuracy: 0.2% F.S
140 * Long-Term Stability: ±0.2% F.S / Year
141 * Overload 200% F.S
142 * Zero Temperature Drift: ±2% F.S)
143 * FS Temperature Drift: ±2% F.S
144 * Storage temperature: -30℃~~80℃
145 * Operating temperature: -40℃~~85℃
146 * Material: 316 stainless steels
147
148
149
150 == 1.5 Probe Dimension ==
151
152
153
154 == 1.6 Application and Installation ==
155
156 === 1.6.1 Thread Installation Type ===
157
158
159 (% style="color:blue" %)**Application:**
160
161 * Hydraulic Pressure
162 * Petrochemical Industry
163 * Health and Medical
164 * Food & Beverage Processing
165 * Auto-controlling house
166 * Constant Pressure Water Supply
167 * Liquid Pressure measuring
168
169 Order the suitable thread size and install to measure the air / liquid pressure
170
171 [[image:1675071670469-145.png]]
172
173
174 === 1.6.2 Immersion Type ===
175
176
177 (% style="color:blue" %)**Application:**
178
179 Liquid & Water Pressure / Level detect.
180
181 [[image:1675071725288-579.png]]
182
183
184 The Immersion Type pressure sensor is shipped with the probe and device separately. When user got the device, below is the wiring to for connect the probe to the device.
185
186
187 [[image:1675071736646-450.png]]
188
189
190 [[image:1675071776102-240.png]]
191
192
193 == 1.7 Sleep mode and working mode ==
194
195
196 (% style="color:blue" %)**Deep Sleep Mode: **(%%)Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life.
197
198 (% style="color:blue" %)**Working Mode:** (%%)In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode.
199
200
201 == 1.8 Button & LEDs ==
202
203
204 [[image:1675071855856-879.png]]
205
206
207 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
208 |=(% style="width: 167px;" %)**Behavior on ACT**|=(% style="width: 117px;" %)**Function**|=(% style="width: 225px;" %)**Action**
209 |(% style="width:167px" %)Pressing ACT between 1s < time < 3s|(% style="width:117px" %)Send an uplink|(% style="width:225px" %)(((
210 If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, (% style="color:blue" %)**blue led** (%%)will blink once.
211 Meanwhile, BLE module will be active and user can connect via BLE to configure device.
212 )))
213 |(% style="width:167px" %)Pressing ACT for more than 3s|(% style="width:117px" %)Active Device|(% style="width:225px" %)(((
214 (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:#037691" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network.
215 (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network.
216 Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network.
217 )))
218 |(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode.
219
220
221
222 == 1.9 Pin Mapping ==
223
224
225 [[image:1675072568006-274.png]]
226
227
228 == 1.10 BLE connection ==
229
230
231 PS-LB support BLE remote configure.
232
233
234 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case:
235
236 * Press button to send an uplink
237 * Press button to active device.
238 * Device Power on or reset.
239
240 If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode.
241
242
243 == 1.11 Mechanical ==
244
245
246 [[image:1675143884058-338.png]]
247
248
249 [[image:1675143899218-599.png]]
250
251
252 [[image:1675143909447-639.png]]
253
254
255 = 2. Configure PS-LB to connect to LoRaWAN network =
256
257 == 2.1 How it works ==
258
259
260 The PS-LB is configured as (% style="color:#037691" %)**LoRaWAN OTAA Class A**(%%) mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and activate the PS-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
261
262
263 == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
264
265
266 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LPS8v2>>url:https://www.dragino.com/products/lora-lorawan-gateway/item/228-lps8v2.html]] as a LoRaWAN gateway in this example.
267
268
269 [[image:1675144005218-297.png]]
270
271
272 The LPS8V2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
273
274
275 (% style="color:blue" %)**Step 1:**(%%) Create a device in TTN with the OTAA keys from PS-LB.
276
277 Each PS-LB is shipped with a sticker with the default device EUI as below:
278
279 [[image:image-20230131134744-2.jpeg]]
280
281
282
283 You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot:
284
285
286 (% style="color:blue" %)**Register the device**
287
288 [[image:1675144099263-405.png]]
289
290
291 (% style="color:blue" %)**Add APP EUI and DEV EUI**
292
293 [[image:1675144117571-832.png]]
294
295
296 (% style="color:blue" %)**Add APP EUI in the application**
297
298
299 [[image:1675144143021-195.png]]
300
301
302 (% style="color:blue" %)**Add APP KEY**
303
304 [[image:1675144157838-392.png]]
305
306 (% style="color:blue" %)**Step 2:**(%%) Activate on PS-LB
307
308
309 Press the button for 5 seconds to activate the PS-LB.
310
311 (% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:blue" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. (% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network.
312
313 After join success, it will start to upload messages to TTN and you can see the messages in the panel.
314
315
316 == 2.3 ​Uplink Payload ==
317
318
319 Uplink payloads have two types:
320
321 * Distance Value: Use FPORT=2
322 * Other control commands: Use other FPORT fields.
323
324 The application server should parse the correct value based on FPORT settings.
325
326
327 === 2.3.1 Device Status, FPORT~=5 ===
328
329
330 Include device configure status. Once PS-LB Joined the network, it will uplink this message to the server.
331
332 Users can also use the downlink command(0x26 01) to ask PS-LB to resend this uplink.
333
334
335 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
336 |(% colspan="6" %)**Device Status (FPORT=5)**
337 |(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2**
338 |(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT
339
340 Example parse in TTNv3
341
342 [[image:1675144504430-490.png]]
343
344
345 (% style="color:#037691" %)**Sensor Model**(%%): For PS-LB, this value is 0x16
346
347 (% style="color:#037691" %)**Firmware Version**(%%): 0x0100, Means: v1.0.0 version
348
349 (% style="color:#037691" %)**Frequency Band**:
350
351 *0x01: EU868
352
353 *0x02: US915
354
355 *0x03: IN865
356
357 *0x04: AU915
358
359 *0x05: KZ865
360
361 *0x06: RU864
362
363 *0x07: AS923
364
365 *0x08: AS923-1
366
367 *0x09: AS923-2
368
369 *0x0a: AS923-3
370
371 *0x0b: CN470
372
373 *0x0c: EU433
374
375 *0x0d: KR920
376
377 *0x0e: MA869
378
379
380 (% style="color:#037691" %)**Sub-Band**:
381
382 AU915 and US915:value 0x00 ~~ 0x08
383
384 CN470: value 0x0B ~~ 0x0C
385
386 Other Bands: Always 0x00
387
388
389 (% style="color:#037691" %)**Battery Info**:
390
391 Check the battery voltage.
392
393 Ex1: 0x0B45 = 2885mV
394
395 Ex2: 0x0B49 = 2889mV
396
397
398 === 2.3.2 Sensor value, FPORT~=2 ===
399
400
401 Uplink payload includes in total 9 bytes.
402
403
404 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
405 |(% style="width:97px" %)(((
406 **Size(bytes)**
407 )))|(% style="width:48px" %)**2**|(% style="width:71px" %)**2**|(% style="width:98px" %)**2**|(% style="width:73px" %)**2**|(% style="width:122px" %)**1**
408 |(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt  flag>>||anchor="H2.3.7IN126IN226INTpin"]]
409
410 [[image:1675144608950-310.png]]
411
412
413 === 2.3.3 Sensor value, FPORT~=7 ===
414
415
416 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %)
417 |(% style="width:94px" %)(((
418 **Size(bytes)**
419 )))|(% style="width:43px" %)2|(% style="width:367px" %)n
420 |(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:367px" %)(((
421 Voltage value, each 2 bytes is a set of voltage values.
422 )))
423
424 [[image:image-20230220171300-1.png||height="207" width="863"]]
425
426
427 === 2.3.4 Battery Info ===
428
429
430 Check the battery voltage for PS-LB.
431
432 Ex1: 0x0B45 = 2885mV
433
434 Ex2: 0x0B49 = 2889mV
435
436
437 === 2.3.5 Probe Model ===
438
439
440 PS-LB has different kind of probe, 0~~20mA represent the full scale of the measuring range. So a 15mA output means different meaning for different probe. 
441
442
443 For example.
444
445 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
446 |(% style="width:111px" %)**Part Number**|(% style="width:158px" %)**Probe Used**|**0~~20mA scale**|**Example: 10mA meaning**
447 |(% style="width:111px" %)PS-LB-I3|(% style="width:158px" %)immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water
448 |(% style="width:111px" %)PS-LB-I5|(% style="width:158px" %)immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water
449
450 The probe model field provides the convenient for server to identical how it should parse the 0~~20mA sensor value and get the correct value.
451
452
453 === 2.3.6 0~~20mA value (IDC_IN) ===
454
455
456 The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level.
457
458 (% style="color:#037691" %)**Example**:
459
460 27AE(H) = 10158 (D)/1000 = 10.158mA.
461
462
463 === 2.3.7 0~~30V value ( pin VDC_IN) ===
464
465
466 Measure the voltage value. The range is 0 to 30V.
467
468 (% style="color:#037691" %)**Example**:
469
470 138E(H) = 5006(D)/1000= 5.006V
471
472
473 === 2.3.8 IN1&IN2&INT pin ===
474
475
476 IN1 and IN2 are used as digital input pins.
477
478 (% style="color:#037691" %)**Example**:
479
480 09 (H): (0x09&0x08)>>3=1    IN1 pin is high level.
481
482 09 (H): (0x09&0x04)>>2=0    IN2 pin is low level.
483
484
485 This data field shows if this packet is generated by (% style="color:blue" %)**Interrupt Pin** (%%)or not. [[Click here>>||anchor="H3.2SetInterruptMode"]] for the hardware and software set up. Note: The Internet Pin is a separate pin in the screw terminal.
486
487 (% style="color:#037691" %)**Example:**
488
489 09 (H): (0x09&0x02)>>1=1    The level of the interrupt pin.
490
491 09 (H): 0x09&0x01=1              0x00: Normal uplink packet.
492
493 0x01: Interrupt Uplink Packet.
494
495
496 === 2.3.9 ​Decode payload in The Things Network ===
497
498
499 While using TTN network, you can add the payload format to decode the payload.
500
501
502 [[image:1675144839454-913.png]]
503
504
505 PS-LB TTN Payload Decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>url:https://github.com/dragino/dragino-end-node-decoder]]
506
507
508 == 2.4 Uplink Interval ==
509
510
511 The PS-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval||style="background-color: rgb(255, 255, 255);"]]
512
513
514 == 2.5 Show Data in DataCake IoT Server ==
515
516
517 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
518
519
520 (% style="color:blue" %)**Step 1: **(%%)Be sure that your device is programmed and properly connected to the network at this time.
521
522 (% style="color:blue" %)**Step 2:**(%%) To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:
523
524
525 [[image:1675144951092-237.png]]
526
527
528 [[image:1675144960452-126.png]]
529
530
531 (% style="color:blue" %)**Step 3:**(%%) Create an account or log in Datacake.
532
533 (% style="color:blue" %)**Step 4:** (%%)Create PS-LB product.
534
535 [[image:1675145004465-869.png]]
536
537
538 [[image:1675145018212-853.png]]
539
540
541
542
543 [[image:1675145029119-717.png]]
544
545
546 (% style="color:blue" %)**Step 5: **(%%)add payload decode
547
548 [[image:1675145051360-659.png]]
549
550
551 [[image:1675145060812-420.png]]
552
553
554 After added, the sensor data arrive TTN, it will also arrive and show in Datacake.
555
556
557 [[image:1675145081239-376.png]]
558
559
560 == 2.6 Frequency Plans ==
561
562
563 The PS-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
564
565 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
566
567
568 == 2.7 ​Firmware Change Log ==
569
570
571 **Firmware download link:**
572
573 [[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]]
574
575
576
577 = 3. Configure PS-LB via AT Command or LoRaWAN Downlink =
578
579
580 Use can configure PS-LB via AT Command or LoRaWAN Downlink.
581
582 * AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]].
583 * LoRaWAN Downlink instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section.
584
585 There are two kinds of commands to configure PS-LB, they are:
586
587 * (% style="color:#037691" %)**General Commands**
588
589 These commands are to configure:
590
591 * General system settings like: uplink interval.
592 * LoRaWAN protocol & radio related command.
593
594 They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:
595
596 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
597
598
599 * (% style="color:#037691" %)**Commands special design for PS-LB**
600
601 These commands only valid for PS-LB, as below:
602
603
604 == 3.1 Set Transmit Interval Time ==
605
606
607 Feature: Change LoRaWAN End Node Transmit Interval.
608
609 (% style="color:blue" %)**AT Command: AT+TDC**
610
611 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
612 |=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response**
613 |(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|(((
614 30000
615 OK
616 the interval is 30000ms = 30s
617 )))
618 |(% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|(((
619 OK
620 Set transmit interval to 60000ms = 60 seconds
621 )))
622
623 (% style="color:blue" %)**Downlink Command: 0x01**
624
625 Format: Command Code (0x01) followed by 3 bytes time value.
626
627 If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01.
628
629 * Example 1: Downlink Payload: 0100001E  ~/~/  Set Transmit Interval (TDC) = 30 seconds
630 * Example 2: Downlink Payload: 0100003C  ~/~/  Set Transmit Interval (TDC) = 60 seconds
631
632
633
634 == 3.2 Set Interrupt Mode ==
635
636
637 Feature, Set Interrupt mode for GPIO_EXIT.
638
639 (% style="color:blue" %)**AT Command: AT+INTMOD**
640
641 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
642 |=(% style="width: 154px;" %)**Command Example**|=(% style="width: 196px;" %)**Function**|=(% style="width: 157px;" %)**Response**
643 |(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
644 0
645 OK
646 the mode is 0 = No interruption
647 )))
648 |(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((
649 Set Transmit Interval
650 ~1. (Disable Interrupt),
651 2. (Trigger by rising and falling edge)
652 3. (Trigger by falling edge)
653 4. (Trigger by rising edge)
654 )))|(% style="width:157px" %)OK
655
656 (% style="color:blue" %)**Downlink Command: 0x06**
657
658 Format: Command Code (0x06) followed by 3 bytes.
659
660 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
661
662 * Example 1: Downlink Payload: 06000000  ~/~/  Turn off interrupt mode
663 * Example 2: Downlink Payload: 06000003  ~/~/  Set the interrupt mode to rising edge trigger
664
665
666
667 == 3.3 Set the output time ==
668
669
670 Feature, Control the output 3V3 , 5V or 12V.
671
672 (% style="color:blue" %)**AT Command: AT+3V3T**
673
674 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:474px" %)
675 |=(% style="width: 154px;" %)**Command Example**|=(% style="width: 201px;" %)**Function**|=(% style="width: 116px;" %)**Response**
676 |(% style="width:154px" %)AT+3V3T=?|(% style="width:201px" %)Show 3V3 open time.|(% style="width:116px" %)(((
677 0
678 OK
679 )))
680 |(% style="width:154px" %)AT+3V3T=0|(% style="width:201px" %)Normally open 3V3 power supply.|(% style="width:116px" %)(((
681 OK
682 default setting
683 )))
684 |(% style="width:154px" %)AT+3V3T=1000|(% style="width:201px" %)Close after a delay of 1000 milliseconds.|(% style="width:116px" %)(((
685 OK
686 )))
687 |(% style="width:154px" %)AT+3V3T=65535|(% style="width:201px" %)Normally closed 3V3 power supply.|(% style="width:116px" %)(((
688 OK
689 )))
690
691 (% style="color:blue" %)**AT Command: AT+5VT**
692
693 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:470px" %)
694 |=(% style="width: 155px;" %)**Command Example**|=(% style="width: 196px;" %)**Function**|=(% style="width: 114px;" %)**Response**
695 |(% style="width:155px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:114px" %)(((
696 0
697 OK
698 )))
699 |(% style="width:155px" %)AT+5VT=0|(% style="width:196px" %)Normally closed 5V power supply.|(% style="width:114px" %)(((
700 OK
701 default setting
702 )))
703 |(% style="width:155px" %)AT+5VT=1000|(% style="width:196px" %)Close after a delay of 1000 milliseconds.|(% style="width:114px" %)(((
704 OK
705 )))
706 |(% style="width:155px" %)AT+5VT=65535|(% style="width:196px" %)Normally open 5V power supply.|(% style="width:114px" %)(((
707 OK
708 )))
709
710 (% style="color:blue" %)**AT Command: AT+12VT**
711
712 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:443px" %)
713 |=(% style="width: 156px;" %)**Command Example**|=(% style="width: 199px;" %)**Function**|=(% style="width: 83px;" %)**Response**
714 |(% style="width:156px" %)AT+12VT=?|(% style="width:199px" %)Show 12V open time.|(% style="width:83px" %)(((
715 0
716 OK
717 )))
718 |(% style="width:156px" %)AT+12VT=0|(% style="width:199px" %)Normally closed 12V power supply.|(% style="width:83px" %)OK
719 |(% style="width:156px" %)AT+12VT=500|(% style="width:199px" %)Close after a delay of 500 milliseconds.|(% style="width:83px" %)(((
720 OK
721 )))
722
723 (% style="color:blue" %)**Downlink Command: 0x07**
724
725 Format: Command Code (0x07) followed by 3 bytes.
726
727 The first byte is which power, the second and third bytes are the time to turn on.
728
729 * Example 1: Downlink Payload: 070101F4  **~-~-->**  AT+3V3T=500
730 * Example 2: Downlink Payload: 0701FFFF   **~-~-->**  AT+3V3T=65535
731 * Example 3: Downlink Payload: 070203E8  **~-~-->**  AT+5VT=1000
732 * Example 4: Downlink Payload: 07020000  **~-~-->**  AT+5VT=0
733 * Example 5: Downlink Payload: 070301F4  **~-~-->**  AT+12VT=500
734 * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
735
736
737
738 == 3.4 Set the Probe Model ==
739
740
741 (% style="color:blue" %)**AT Command: AT** **+PROBE**
742
743 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:448px" %)
744 |=(% style="width: 154px;" %)**Command Example**|=(% style="width: 204px;" %)**Function**|=(% style="width: 85px;" %)**Response**
745 |(% style="width:154px" %)AT +PROBE =?|(% style="width:204px" %)Get or Set the probe model.|(% style="width:85px" %)(((
746 0
747 OK
748 )))
749 |(% style="width:154px" %)AT +PROBE =0003|(% style="width:204px" %)Set water depth sensor mode, 3m type.|(% style="width:85px" %)OK
750 |(% style="width:154px" %)AT +PROBE =0101|(% style="width:204px" %)Set pressure transmitters mode, first type.|(% style="width:85px" %)(((
751 OK
752 )))
753 |(% style="width:154px" %)AT +PROBE =0000|(% style="width:204px" %)Initial state, no settings.|(% style="width:85px" %)(((
754 OK
755 )))
756
757 (% style="color:blue" %)**Downlink Command: 0x08**
758
759 Format: Command Code (0x08) followed by 2 bytes.
760
761 * Example 1: Downlink Payload: 080003  **~-~-->**  AT+PROBE=0003
762 * Example 2: Downlink Payload: 080101  **~-~-->**  AT+PROBE=0101
763
764
765
766 == 3.5 Multiple collections are one uplink(Since firmware V1.1) ==
767
768
769 Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time.
770
771 (% style="color:blue" %)**AT Command: AT** **+STDC**
772
773 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
774 |=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response**
775 |(% style="width:156px" %)AT+STDC=?|(% style="width:137px" %)(((
776 Get the mode of multiple acquisitions and one uplink
777 )))|(((
778 1,10,18
779 OK
780 )))
781 |(% style="width:156px" %)AT+STDC=1,10,18|(% style="width:137px" %)Set the mode of multiple acquisitions and one uplink|(((
782 OK
783 (% style="color:#037691" %)**aa:**(%%)
784 **0:** means disable this function and use TDC to send packets.
785 **1:** means enable this function, use the method of multiple acquisitions to send packets.
786 (% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535
787 (% style="color:#037691" %)**cc: **(%%)the number of collection times, the value is 1~~120
788 )))
789
790 (% style="color:blue" %)**Downlink Command: 0xAE**
791
792 Format: Command Code (0x08) followed by 5 bytes.
793
794 * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->**  AT+STDC=1,600,18
795
796
797
798 = 4. Battery & how to replace =
799
800 == 4.1 Battery Type ==
801
802
803 PS-LB is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>https://www.dropbox.com/sh/w9l2oa3ytpculph/AAAPtt-apH4lYfCj-2Y6lHvQa?dl=0]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
804
805 The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
806
807 [[image:1675146710956-626.png]]
808
809
810 Minimum Working Voltage for the PS-LB:
811
812 PS-LB:  2.45v ~~ 3.6v
813
814
815 == 4.2 Replace Battery ==
816
817
818 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
819
820 And make sure the positive and negative pins match.
821
822
823 == 4.3 Power Consumption Analyze ==
824
825
826 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
827
828 Instruction to use as below:
829
830 (% style="color:blue" %)**Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0>>https://www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0]]
831
832 (% style="color:blue" %)**Step 2:**(%%) Open it and choose
833
834 * Product Model
835 * Uplink Interval
836 * Working Mode
837
838 And the Life expectation in difference case will be shown on the right.
839
840 [[image:1675146895108-304.png]]
841
842
843 The battery related documents as below:
844
845 * [[Battery Dimension>>https://www.dropbox.com/s/ox5g9njwjle7aw3/LSN50-Battery-Dimension.pdf?dl=0]],
846 * [[Lithium-Thionyl Chloride Battery datasheet, Tech Spec>>https://www.dropbox.com/sh/d4oyfnp8o94180o/AABQewCNSh5GPeQH86UxRgQQa?dl=0]]
847 * [[Lithium-ion Battery-Capacitor datasheet>>https://www.dropbox.com/s/791gjes2lcbfi1p/SPC_1520_datasheet.jpg?dl=0]], [[Tech Spec>>https://www.dropbox.com/s/4pkepr9qqqvtzf2/SPC1520%20Technical%20Specification20171123.pdf?dl=0]]
848
849 [[image:image-20230131145708-3.png]]
850
851
852 === 4.3.1 ​Battery Note ===
853
854
855 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
856
857
858 === 4.3.2 Replace the battery ===
859
860
861 You can change the battery in the PS-LB.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
862
863 The default battery pack of PS-LB includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
864
865
866 = 5. Remote Configure device =
867
868 == 5.1 Connect via BLE ==
869
870
871 Please see this instruction for how to configure via BLE: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]
872
873
874 == 5.2 AT Command Set ==
875
876
877
878 = 6. OTA firmware update =
879
880
881 Please see this link for how to do OTA firmware update: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
882
883
884 = 7. FAQ =
885
886 == 7.1 How to use AT Command to access device? ==
887
888
889 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]
890
891
892 == 7.2 How to update firmware via UART port? ==
893
894
895 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]
896
897
898 == 7.3 How to change the LoRa Frequency Bands/Region? ==
899
900
901 You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]].
902 When downloading the images, choose the required image file for download. ​
903
904
905 = 8. Order Info =
906
907
908 [[image:image-20230131153105-4.png]]
909
910
911 = 9. ​Packing Info =
912
913
914 (% style="color:#037691" %)**Package Includes**:
915
916 * PS-LB LoRaWAN Pressure Sensor
917
918 (% style="color:#037691" %)**Dimension and weight**:
919
920 * Device Size: cm
921 * Device Weight: g
922 * Package Size / pcs : cm
923 * Weight / pcs : g
924
925
926
927 = 10. Support =
928
929
930 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
931
932 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]