19
20
21 = 1. Introduction =
22
23 == 1.1 What is LoRaWAN Pressure Sensor ==
24
25
26 The Dragino PS-LB series sensors are **LoRaWAN Pressure Sensor** for Internet of Things solution. PS-LB can measure Air, Water pressure and liquid level and upload the sensor data via wireless to LoRaWAN IoT server.
27
28 The PS-LB series sensors include **Thread Installation Type** and **Immersion Type**, it supports different pressure range which can be used for different measurement requirement.
29
30 The LoRa wireless technology used in PS-LB allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption.
31
32 PS-LB supports BLE configure and wireless OTA update which make user easy to use.
33
34 PS-LB is powered by **8500mAh Li-SOCI2 battery**, it is designed for long term use up to 5 years.
35
36 Each PS-LB is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on.
37
38 [[image:1675071321348-194.png]]
39
40
41
42 == 1.2 ​Features ==
43
44
45 * LoRaWAN 1.0.3 Class A
46 * Ultra-low power consumption
47 * Measure air / gas or water pressure
48 * Different pressure range available
49 * Thread Installation Type or Immersion Type
50 * Monitor Battery Level
51 * Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/IN865
52 * Support Bluetooth v5.1 and LoRaWAN remote configure
53 * Support wireless OTA update firmware
54 * Uplink on periodically
55 * Downlink to change configure
56 * 8500mAh Battery for long term use
57
58
59 == 1.3 Specification ==
60
61
62 **Micro Controller:**
63
64 * MCU: 48Mhz ARM
65 * Flash: 256KB
66 * RAM: 64KB
67
68 **Common DC Characteristics:**
69
70 * Supply Voltage: 2.5v ~~ 3.6v
71 * Operating Temperature: -40 ~~ 85°C
72
73 **LoRa Spec:**
74
75 * Frequency Range,  Band 1 (HF): 862 ~~ 1020 Mhz
76 * Max +22 dBm constant RF output vs.
77 * RX sensitivity: down to -139 dBm.
78 * Excellent blocking immunity
79
80 **Current Input Measuring :**
81
82 * Range: 0 ~~ 20mA
83 * Accuracy: 0.02mA
84 * Resolution: 0.001mA
85
86 **Voltage Input Measuring:**
87
88 * Range: 0 ~~ 30v
89 * Accuracy: 0.02v
90 * Resolution: 0.001v
91
92 **Battery:**
93
94 * Li/SOCI2 un-chargeable battery
95 * Capacity: 8500mAh
96 * Self-Discharge: <1% / Year @ 25°C
97 * Max continuously current: 130mA
98 * Max boost current: 2A, 1 second
99
100 **Power Consumption**
101
102 * Sleep Mode: 5uA @ 3.3v
103 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm
104
105
106 == 1.4 Probe Types ==
107
108 === 1.4.1 Thread Installation Type ===
109
110
111 [[image:1675071448299-229.png]]
112
113 * Hersman Pressure Transmitter
114 * Measuring Range: -0.1 ~~ 0 ~~ 60MPa, see order info.
115 * Accuracy: 0.2% F.S
116 * Long-Term Stability: 0.2% F.S ±0.05%
117 * Overload 200% F.S
118 * Zero Temperature Drift: 0.03% FS/℃(≤100Kpa), 0.02%FS/℃(>100Kpa)
119 * FS Temperature Drift: 0.003% FS/℃(≤100Kpa), 0.002%FS/℃(>100Kpa)
120 * Storage temperature: -30℃~~80℃
121 * Operating temperature: -20℃~~60℃
122 * Connector Type: Various Types, see order info
123
124
125 === 1.4.2 Immersion Type ===
126
127
128 [[image:1675071521308-426.png]]
129
130 * Immersion Type, Probe IP Level: IP68
131 * Measuring Range: Measure range can be customized, up to 100m.
132 * Accuracy: 0.2% F.S
133 * Long-Term Stability: ±0.2% F.S / Year
134 * Overload 200% F.S
135 * Zero Temperature Drift: ±2% F.S)
136 * FS Temperature Drift: ±2% F.S
137 * Storage temperature: -30℃~~80℃
138 * Operating temperature: -40℃~~85℃
139 * Material: 316 stainless steels
140
141
142 == 1.5 Probe Dimension ==
143
144
145
146
147 == 1.6 Application and Installation ==
148
149 === 1.6.1 Thread Installation Type ===
150
151
152 **Application:**
153
154 * Hydraulic Pressure
155 * Petrochemical Industry
156 * Health and Medical
157 * Food & Beverage Processing
158 * Auto-controlling house
159 * Constant Pressure Water Supply
160 * Liquid Pressure measuring
161
162 Order the suitable thread size and install to measure the air / liquid pressure
163
164 [[image:1675071670469-145.png]]
165
166
167 === 1.6.2 Immersion Type ===
168
169
170 **Application:**
171
172 Liquid & Water Pressure / Level detect.
173
174 [[image:1675071725288-579.png]]
175
176
177 The Immersion Type pressure sensor is shipped with the probe and device separately. When user got the device, below is the wiring to for connect the probe to the device.
178
179
180 [[image:1675071736646-450.png]]
181
182
183 [[image:1675071776102-240.png]]
184
185
186 == 1.7 Sleep mode and working mode ==
187
188
189 **Deep Sleep Mode: **Sensor doesn't have any LoRaWAN activate. This mode is used for storage and shipping to save battery life.
190
191 **Working Mode:** In this mode, Sensor will work as LoRaWAN Sensor to Join LoRaWAN network and send out sensor data to server. Between each sampling/tx/rx periodically, sensor will be in IDLE mode), in IDLE mode, sensor has the same power consumption as Deep Sleep mode.
192
193
194 == 1.8 Button & LEDs ==
195
196
197 [[image:1675071855856-879.png]]
198
199
200 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
201 |(% style="width:138px" %)**Behavior on ACT**|(% style="width:100px" %)**Function**|**Action**
202 |(% style="width:138px" %)Pressing ACT between 1s < time < 3s|(% style="width:100px" %)Send an uplink|(((
203 If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, **blue led** will blink once.
204
205 Meanwhile, BLE module will be active and user can connect via BLE to configure device.
206 )))
207 |(% style="width:138px" %)Pressing ACT for more than 3s|(% style="width:100px" %)Active Device|(((
208 **Green led** will fast blink 5 times, device will enter **OTA mode** for 3 seconds. And then start to JOIN LoRaWAN network.
209
210 **Green led** will solidly turn on for 5 seconds after joined in network.
211
212 Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network.
213 )))
214 |(% style="width:138px" %)Fast press ACT 5 times.|(% style="width:100px" %)Deactivate Device|red led will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode.
215
216
217
218 == 1.9 Pin Mapping ==
219
220
221 [[image:1675072568006-274.png]]
222
223
224 == 1.10 BLE connection ==
225
226
227 PS-LB support BLE remote configure.
228
229
230 BLE can be used to configure the parameter of sensor or see the console output from sensor. BLE will be only activate on below case:
231
232 * Press button to send an uplink
233 * Press button to active device.
234 * Device Power on or reset.
235
236 If there is no activity connection on BLE in 60 seconds, sensor will shut down BLE module to enter low power mode.
237
238
239 == 1.11 Mechanical ==
240
241
242
243
244 [[image:1675143884058-338.png]]
245
246
247 [[image:1675143899218-599.png]]
248
249
250 [[image:1675143909447-639.png]]
251
252
253 = 2. Configure PS-LB to connect to LoRaWAN network =
254
255 == 2.1 How it works ==
256
257
258 The PS-LB is configured as **LoRaWAN OTAA Class A** mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and activate the PS-LB. It will automatically join the network via OTAA and start to send the sensor value. The default uplink interval is 20 minutes.
259
260
261
262 == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
263
264
265 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LPS8v2>>url:https://www.dragino.com/products/lora-lorawan-gateway/item/228-lps8v2.html]] as a LoRaWAN gateway in this example.
266
267
268 [[image:1675144005218-297.png]]
269
270
271 The LPS8V2 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server.
272
273
274 **Step 1**: Create a device in TTN with the OTAA keys from PS-LB.
275
276 Each PS-LB is shipped with a sticker with the default device EUI as below:
277
278 [[image:image-20230131134744-2.jpeg]]
279
280
281
282 You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot:
283
284
285 **Register the device**
286
287 [[image:1675144099263-405.png]]
288
289
290 **Add APP EUI and DEV EUI**
291
292 [[image:1675144117571-832.png]]
293
294
295 **Add APP EUI in the application**
296
297
298 [[image:1675144143021-195.png]]
299
300
301 **Add APP KEY**
302
303 [[image:1675144157838-392.png]]
304
305 **Step 2**: Activate on PS-LB
306
307
308 Press the button for 5 seconds to activate the PS-LB.
309
310 **Green led** will fast blink 5 times, device will enter **OTA mode** for 3 seconds. And then start to JOIN LoRaWAN network. **Green led** will solidly turn on for 5 seconds after joined in network.
311
312 After join success, it will start to upload messages to TTN and you can see the messages in the panel.
313
314
315
316 == 2.3 ​Uplink Payload ==
317
318
319 Uplink payloads have two types:
320
321 * Distance Value: Use FPORT=2
322 * Other control commands: Use other FPORT fields.
323
324 The application server should parse the correct value based on FPORT settings.
325
326
327 === 2.3.1 Device Status, FPORT~=5 ===
328
329
330 Include device configure status. Once PS-LB Joined the network, it will uplink this message to the server.
331
332 Users can also use the downlink command(0x26 01) to ask PS-LB to resend this uplink.
333
334
335 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
336 |(% colspan="6" %)**Device Status (FPORT=5)**
337 |(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|**1**|**1**|**2**
338 |(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|Frequency Band|Sub-band|BAT
339
340 Example parse in TTNv3
341
342 [[image:1675144504430-490.png]]
343
344
345 **Sensor Model**: For PS-LB, this value is 0x16
346
347 **Firmware Version**: 0x0100, Means: v1.0.0 version
348
349 **Frequency Band**:
350
351 *0x01: EU868
352
353 *0x02: US915
354
355 *0x03: IN865
356
357 *0x04: AU915
358
359 *0x05: KZ865
360
361 *0x06: RU864
362
363 *0x07: AS923
364
365 *0x08: AS923-1
366
367 *0x09: AS923-2
368
369 *0x0a: AS923-3
370
371 *0x0b: CN470
372
373 *0x0c: EU433
374
375 *0x0d: KR920
376
377 *0x0e: MA869
378
379
380 **Sub-Band**:
381
382 AU915 and US915:value 0x00 ~~ 0x08
383
384 CN470: value 0x0B ~~ 0x0C
385
386 Other Bands: Always 0x00
387
388
389 **Battery Info**:
390
391 Check the battery voltage.
392
393 Ex1: 0x0B45 = 2885mV
394
395 Ex2: 0x0B49 = 2889mV
396
397
398 === 1.3.2 Sensor value, FPORT~=2 ===
399
400
401 Uplink payload includes in total 9 bytes.
402
403
404 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
405 |(% style="width:97px" %)(((
406 **Size(bytes)**
407 )))|(% style="width:48px" %)**2**|(% style="width:58px" %)**2**|**2**|**2**|**1**
408 |(% style="width:97px" %)**Value**|(% style="width:48px" %)[[BAT>>path:#bat]]|(% style="width:58px" %)[[Probe Model>>path:#Probe_Model]]|0 ~~ 20mA value|[[0 ~~~~ 30v value>>path:#Voltage_30v]]|[[IN1 &IN2 Interrupt  flag>>path:#Int_pin]]
409
410 [[image:1675144608950-310.png]]
411
412
413
414 === 2.3.3 Battery Info ===
415
416
417 Check the battery voltage for PS-LB.
418
419 Ex1: 0x0B45 = 2885mV
420
421 Ex2: 0x0B49 = 2889mV
422
423
424 === 2.3.4 Probe Model ===
425
426
427 PS-LB has different kind of probe, 0~~20mA represent the full scale of the measuring range. So a 15mA output means different meaning for different probe. 
428
429
430 For example.
431
432 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
433 |(% style="width:111px" %)**Part Number**|(% style="width:158px" %)**Probe Used**|**0~~20mA scale**|**Example: 10mA meaning**
434 |(% style="width:111px" %)PS-LB-I3|(% style="width:158px" %)immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water
435 |(% style="width:111px" %)PS-LB-I5|(% style="width:158px" %)immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water
436
437 The probe model field provides the convenient for server to identical how it should parse the 0~~20mA sensor value and get the correct value.
438
439
440 === 2.3.5 0~~20mA value (IDC_IN) ===
441
442
443 The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level.
444
445 **Example**:
446
447 27AE(H) = 10158 (D)/1000 = 10.158mA.
448
449
450 === 2.3.6 0~~30V value ( pin VDC_IN) ===
451
452
453 Measure the voltage value. The range is 0 to 30V.
454
455 **Example**:
456
457 138E(H) = 5006(D)/1000= 5.006V
458
459
460 === 2.3.7 IN1&IN2&INT pin ===
461
462
463 IN1 and IN2 are used as digital input pins.
464
465 **Example**:
466
467 09 (H) :(0x09&0x08)>>3=1    IN1 pin is high level.
468
469 09 (H) :(0x09&0x04)>>2=0    IN2 pin is low level.
470
471
472 This data field shows if this packet is generated by **Interrupt Pin** or not. [[Click here>>path:#Int_mod]] for the hardware and software set up. Note: The Internet Pin is a separate pin in the screw terminal.
473
474 **Example:**
475
476 09 (H) : (0x09&0x02)>>1=1    The level of the interrupt pin.
477
478 09 (H) : 0x09&0x01=1              0x00: Normal uplink packet.
479
480 0x01: Interrupt Uplink Packet.
481
482
483 === 2.3.8 ​Decode payload in The Things Network ===
484
485
486 While using TTN network, you can add the payload format to decode the payload.
487
488
489 [[image:1675144839454-913.png]]
490
491
492 PS-LB TTN Payload Decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>url:https://github.com/dragino/dragino-end-node-decoder]]
493
494
495 == 2.4 Uplink Interval ==
496
497
498 The PS-LB by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H4.1ChangeUplinkInterval||style="background-color: rgb(255, 255, 255);"]]
499
500
501 == 2.5 Show Data in DataCake IoT Server ==
502
503
504 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
505
506
507 **Step 1: **Be sure that your device is programmed and properly connected to the network at this time.
508
509 **Step 2:** To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:
510
511
512 [[image:1675144951092-237.png]]
513
514
515 [[image:1675144960452-126.png]]
516
517
518 **Step 3:** Create an account or log in Datacake.
519
520 **Step 4:** Create PS-LB product.
521
522 [[image:1675145004465-869.png]]
523
524
525 [[image:1675145018212-853.png]]
526
527
528
529
530 [[image:1675145029119-717.png]]
531
532
533 **Step 5: **add payload decode
534
535 [[image:1675145051360-659.png]]
536
537
538 [[image:1675145060812-420.png]]
539
540
541
542 After added, the sensor data arrive TTN, it will also arrive and show in Datacake.
543
544
545 [[image:1675145081239-376.png]]
546
547
548 == 2.6 Frequency Plans ==
549
550
551 The PS-LB uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
552
553 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
554
555
556
557
558 1.
559 11. ​Firmware Change Log
560
561 **Firmware download link:**
562
563 [[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]]
564
565
566
567 1. Configure PS-LB via AT Command or LoRaWAN Downlink
568
569 Use can configure PS-LB via AT Command or LoRaWAN Downlink.
570
571 * AT Command Connection: See [[FAQ>>path:#AT_COMMAND]].
572 * LoRaWAN Downlink instruction for different platforms:
573
574 [[http:~~/~~/wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server>>url:http://wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server]]
575
576
577 There are two kinds of commands to configure PS-LB, they are:
578
579 * **General Commands**.
580
581 These commands are to configure:
582
583 * General system settings like: uplink interval.
584 * LoRaWAN protocol & radio related command.
585
586 They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:
587
588 [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]]
589
590
591 * **Commands special design for PS-LB**
592
593 These commands only valid for PS-LB, as below:
594
595
596 1.
597 11. Set Transmit Interval Time
598
599 Feature: Change LoRaWAN End Node Transmit Interval.
600
601 **AT Command: AT+TDC**
602
603 |**Command Example**|**Function**|**Response**
604 |AT+TDC=?|Show current transmit Interval|(((
605 30000
606
607 OK
608
609 the interval is 30000ms = 30s
610 )))
611 |AT+TDC=60000|Set Transmit Interval|(((
612 OK
613
614 Set transmit interval to 60000ms = 60 seconds
615 )))
616
617 **Downlink Command: 0x01**
618
619 Format: Command Code (0x01) followed by 3 bytes time value.
620
621 If the downlink payload=0100003C, it means set the END Node’s Transmit Interval to 0x00003C=60(S), while type code is 01.
622
623 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
624 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
625
626
627 1.
628 11. Set Interrupt Mode
629
630 Feature, Set Interrupt mode for GPIO_EXIT.
631
632 **AT Command: AT+INTMOD**
633
634 |**Command Example**|**Function**|**Response**
635 |AT+INTMOD=?|Show current interrupt mode|(((
636 0
637
638 OK
639
640 the mode is 0 = No interruption
641 )))
642 |AT+INTMOD=2|(((
643 Set Transmit Interval
644
645 1. (Disable Interrupt),
646 1. (Trigger by rising and falling edge),
647 1. (Trigger by falling edge)
648 1. (Trigger by rising edge)
649 )))|OK
650
651 **Downlink Command: 0x06**
652
653 Format: Command Code (0x06) followed by 3 bytes.
654
655 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
656
657 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
658 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
659
660 1.
661 11. Set the output time
662
663 Feature, Control the output 3V3 , 5V or 12V.
664
665 **AT Command: AT+3V3T**
666
667 |**Command Example**|**Function**|**Response**
668 |AT+3V3T=?|Show 3V3 open time.|(((
669 0
670
671 OK
672 )))
673 |AT+3V3T=0|Normally open 3V3 power supply.|(((
674 OK
675
676 default setting
677 )))
678 |AT+3V3T=1000|Close after a delay of 1000 milliseconds.|(((
679 OK
680
681
682 )))
683 |AT+3V3T=65535|Normally closed 3V3 power supply.|(((
684 OK
685
686
687 )))
688
689 **AT Command: AT+5VT**
690
691 |**Command Example**|**Function**|**Response**
692 |AT+5VT=?|Show 5V open time.|(((
693 0
694
695 OK
696 )))
697 |AT+5VT=0|Normally closed 5V power supply.|(((
698 OK
699
700 default setting
701 )))
702 |AT+5VT=1000|Close after a delay of 1000 milliseconds.|(((
703 OK
704
705
706 )))
707 |AT+5VT=65535|Normally open 5V power supply.|(((
708 OK
709
710
711 )))
712
713 **AT Command: AT+12VT**
714
715 |**Command Example**|**Function**|**Response**
716 |AT+12VT=?|Show 12V open time.|(((
717 0
718
719 OK
720 )))
721 |AT+12VT=0|Normally closed 12V power supply.|OK
722 |AT+12VT=500|Close after a delay of 500 milliseconds.|(((
723 OK
724
725
726 )))
727
728 **Downlink Command: 0x07**
729
730 Format: Command Code (0x07) followed by 3 bytes.
731
732 The first byte is which power, the second and third bytes are the time to turn on.
733
734 * Example 1: Downlink Payload: 070101F4  -> AT+3V3T=500
735 * Example 2: Downlink Payload: 0701FFFF   -> AT+3V3T=65535
736 * Example 3: Downlink Payload: 070203E8  -> AT+5VT=1000
737 * Example 4: Downlink Payload: 07020000  -> AT+5VT=0
738 * Example 5: Downlink Payload: 070301F4  -> AT+12VT=500
739 * Example 6: Downlink Payload: 07030000  -> AT+12VT=0
740
741 1.
742 11. Set the Probe Model
743
744 **AT Command: AT** **+PROBE**
745
746 |**Command Example**|**Function**|**Response**
747 |AT +PROBE =?|Get or Set the probe model.|(((
748 0
749
750 OK
751 )))
752 |AT +PROBE =0003|Set water depth sensor mode, 3m type.|OK
753 |AT +PROBE =0101|Set pressure transmitters mode, first type.|(((
754 OK
755
756
757 )))
758 |AT +PROBE =0000|Initial state, no settings.|(((
759 OK
760
761
762 )))
763
764 **Downlink Command: 0x08**
765
766 Format: Command Code (0x08) followed by 2 bytes.
767
768 * Example 1: Downlink Payload: 080003  -> AT+PROBE=0003
769 * Example 2: Downlink Payload: 080101  -> AT+PROBE=0101
770
771
772
773 1. Battery & how to replace
774 11. Battery Type
775
776 PS-LB is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
777
778
779 The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
780
781 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image031.png]]
782
783
784 Minimum Working Voltage for the PS-LB:
785
786 PS-LB:  2.45v ~~ 3.6v
787
788
789 1.
790 11. Replace Battery
791
792 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
793
794 And make sure the positive and negative pins match.
795
796
797
798 1.
799 11. Power Consumption Analyze
800
801 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
802
803
804 Instruction to use as below:
805
806
807 Step 1: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
808
809 [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
810
811
812 Step 2: Open it and choose
813
814 * Product Model
815 * Uplink Interval
816 * Working Mode
817
818 And the Life expectation in difference case will be shown on the right.
819
820 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image032.png]]
821
822
823 The battery related documents as below:
824
825 * [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
826 * [[Lithium-Thionyl Chloride Battery>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/ER18505_datasheet-EN.pdf]] datasheet, [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/ER18505_datasheet_PM-ER18505-S-02-LF_EN.pdf]]
827 * [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
828
829 |(((
830 JST-XH-2P connector
831 )))
832
833 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image033.png]]
834
835
836
837 1.
838 11.
839 111. ​Battery Note
840
841 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
842
843
844 1.
845 11.
846 111. ​Replace the battery
847
848 You can change the battery in the PS-LB.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
849
850
851 The default battery pack of PS-LB includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
852
853
854
855
856
857
858 1. Remote Configure device
859 11. Connect via BLE
860
861 Please see this instruction for how to configure via BLE:
862
863 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]
864
865
866 1.
867 11. AT Command Set
868
869 1. OTA firmware update
870
871 Please see this link for how to do OTA firmware update.
872
873 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]
874
875
876
877
878
879 1. FAQ
880 11. How to use AT Command to access device?
881
882 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]
883
884
885 1.
886 11. How to update firmware via UART port?
887
888 See:
889
890 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]]
891
892
893 1.
894 11. How to change the LoRa Frequency Bands/Region
895
896 You can follow the instructions for [[how to upgrade image>>path:#3ygebqi]].
897 When downloading the images, choose the required image file for download. ​
898
899
900
901
902
903 1. Order Info
904
905 [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image034.png]]
906
907
908
909
910
911 1. ​Packing Info
912
913 **Package Includes**:
914
915 * PS-LB LoRaWAN Pressure Sensor
916
917 **Dimension and weight**:
918
919 * Device Size: cm
920 * Device Weight: g
921 * Package Size / pcs : cm
922 * Weight / pcs : g
923
924
925
926 1. ​Support
927
928 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
929 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to
930
931 [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
932
933