43 43  (((
44 -PS-LB/LS is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery **(%%)or (% style="color:blue" %)**solar powered + li-on battery **(%%), it is designed for long term use up to 5 years.
44 +PS-LB/LS is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery **(%%)or (% style="color:blue" %)**solar powered + Li-ion battery **(%%), it is designed for long term use up to 5 years.
45 45  )))
46 46  
47 47  (((
... ... @@ -67,7 +67,7 @@
67 67  * Downlink to change configure
68 68  * Controllable 3.3v,5v and 12v output to power external sensor
69 69  * 8500mAh Li/SOCl2 Battery (PS-LB)
70 -* Solar panel + 3000mAh Li-on battery (PS-LS)
70 +* Solar panel + 3000mAh Li-ion battery (PS-LS)
71 71  
72 72  == 1.3 Specification ==
73 73  
... ... @@ -136,14 +136,14 @@
136 136  === 1.4.2 Immersion Type ===
137 137  
138 138  
139 -[[image:image-20240109160445-5.png||height="284" width="214"]]
139 +[[image:image-20240109160445-5.png||height="221" width="166"]]
140 140  
141 141  * Immersion Type, Probe IP Level: IP68
142 142  * Measuring Range: Measure range can be customized, up to 100m.
143 143  * Accuracy: 0.2% F.S
144 144  * Long-Term Stability: ±0.2% F.S / Year
145 -* Storage temperature: -30~~80
146 -* Operating temperature: 0~~50
145 +* Storage temperature: -30°C~~80°C
146 +* Operating temperature: 0°C~~50°C
147 147  * Material: 316 stainless steels
148 148  
149 149  === 1.4.3 Wireless Differential Air Pressure Sensor ===
... ... @@ -154,8 +154,8 @@
154 154  * Accuracy: 0.5% F.S, resolution is 0.05%.
155 155  * Overload: 300% F.S
156 156  * Zero temperature drift: ±0.03%F.S/°C
157 -* Operating temperature: -20~~60
158 -* Storage temperature:  -20~~60
157 +* Operating temperature: -20°C~~60°C
158 +* Storage temperature:  -20°C~~60°C
159 159  * Compensation temperature: 0~~50°C
160 160  
161 161  == 1.5 Application and Installation ==
... ... @@ -275,7 +275,7 @@
275 275  
276 276  == 1.10 Mechanical ==
277 277  
278 -=== 1.10.1 for LB version(% style="display:none" %) (%%) ===
278 +=== 1.10.1 for LB version ===
279 279  
280 280  
281 281  [[image:image-20240109160800-6.png]]
... ... @@ -669,12 +669,143 @@
669 669  
670 670  The PS-LB/LS uses OTAA mode and below frequency plans by default. Each frequency band use different firmware, user update the firmware to the corresponding band for their country.
671 671  
672 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
672 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/a>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
673 673  
674 674  
675 -== 2.8 ​Firmware Change Log ==
675 +== 2.8 Report on Change Feature (Since firmware V1.1.2) ==
676 676  
677 677  
678 +=== 2.8.1 Uplink payload(Enable ROC) ===
679 +
680 +
681 +Used to Monitor the IDC and VDC increments, and send ROC uplink when the IDC or VDC changes exceed.
682 +
683 +With ROC enabled, the payload is as follows:
684 +
685 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
686 +|(% style="background-color:#4f81bd; color:white; width:97px" %)(((
687 +**Size(bytes)**
688 +)))|(% style="background-color:#4f81bd; color:white; width:48px" %)**2**|(% style="background-color:#4f81bd; color:white; width:71px" %)**2**|(% style="background-color:#4f81bd; color:white; width:98px" %)**2**|(% style="background-color:#4f81bd; color:white; width:73px" %)**2**|(% style="background-color:#4f81bd; color:white; width:122px" %)**1**
689 +|(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)(((
690 +[[IN1 &IN2 Interrupt  flag>>||anchor="H2.3.7IN126IN226INTpin"]]
691 +
692 +& **ROC_flag**
693 +)))
694 +
695 +(% style="color:blue" %)**IN1 &IN2 , Interrupt  flag , ROC_flag:**
696 +
697 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
698 +|(% style="background-color:#4f81bd; color:white; width:55px" %)**Size(bit)**|(% style="background-color:#4f81bd; color:white; width:65px" %)**bit7**|(% style="background-color:#4f81bd; color:white; width:46.5834px" %)**bit6**|(% style="background-color:#4f81bd; color:white; width:1px" %)**bit5**|(% style="background-color:#4f81bd; color:white; width:65px" %)**bit4**|(% style="background-color:#4f81bd; color:white; width:65px" %)**bit3**|(% style="background-color:#4f81bd; color:white; width:105px" %)**bit2**|(% style="background-color:#4f81bd; color:white; width:105px" %)**bit1**|(% style="background-color:#4f81bd; color:white; width:105px" %)**bit0**
699 +|(% style="width:75px" %)Value|(% style="width:89px" %)IDC_Roc_flagL|(% style="width:46.5834px" %)IDC_Roc_flagH|(% style="width:1px" %)VDC_Roc_flagL|(% style="width:89px" %)VDC_Roc_flagH|(% style="width:89px" %)IN1_pin_level|(% style="width:103px" %)IN2_pin_level|(% style="width:103px" %)Exti_pin_level|(% style="width:103px" %)Exti_status
700 +
701 +* (% style="color:#037691" %)**IDC_Roc_flagL**
702 +
703 +80 (H): (0x80&0x80)=80(H)=**1**000 0000(B)  bit7=1, "TRUE", This uplink is triggered when the decrease in the IDC compared to the last ROC refresh exceeds the set threshold.
704 +
705 +60 (H): (0x60&0x80)=0  bit7=0, "FALSE", This uplink is not triggered when the decrease in the IDC compared to the last ROC refresh exceeds the set threshold.
706 +
707 +
708 +* (% style="color:#037691" %)**IDC_Roc_flagH**
709 +
710 +60 (H): (0x60&0x40)=60(H)=0**1**000 0000(B)  bit6=1, "TRUE", This uplink is triggered when the increase in the value of the IDC compared to the last ROC refresh exceeds the set threshold.
711 +
712 +80 (H): (0x80&0x40)=0  bit6=0, "FALSE", This uplink is not triggered when the increase in the value of the IDC compared to the last ROC refresh exceeds the set threshold.
713 +
714 +
715 +* (% style="color:#037691" %)**VDC_Roc_flagL**
716 +
717 +20 (H): (0x20&0x20)=20(H)=00**1**0 0000(B)  bit5=1, "TRUE", This uplink is triggered when the decrease in the VDC compared to the last ROC refresh exceeds the set threshold.
718 +
719 +90 (H): (0x90&0x20)=0  bit5=0, "FALSE", This uplink is not triggered when the decrease in the VDC compared to the last ROC refresh exceeds the set threshold.
720 +
721 +
722 +* (% style="color:#037691" %)**VDC_Roc_flagH**
723 +
724 +90 (H): (0x90&0x10)=10(H)=000**1** 0000(B)  bit4=1, "TRUE", This uplink is triggered when the increase in the value of the VDC compared to the last ROC refresh exceeds the set threshold.
725 +
726 +20 (H): (0x20&0x10)=0  bit4=0, "FALSE", This uplink is not triggered when the increase in the value of the VDC compared to the last ROC refresh exceeds the set threshold.
727 +
728 +
729 +* (% style="color:#037691" %)**IN1_pin_level & IN2_pin_level**
730 +
731 +IN1 and IN2 are used as digital input pins.
732 +
733 +80 (H): (0x80&0x08)=0  IN1 pin is low level.
734 +
735 +80 (H): (0x09&0x04)=0    IN2 pin is low level.
736 +
737 +
738 +* (% style="color:#037691" %)**Exti_pin_level &Exti_status**
739 +
740 +This data field shows whether the packet is generated by an interrupt pin.
741 +
742 +Note: The Internet pin of the old motherboard is a separate pin in the screw terminal, and the interrupt pin of the new motherboard(SIB V1.3) is the **GPIO_EXTI** pin.
743 +
744 +**Exti_pin_level:**  80 (H): (0x80&0x02)=0  "low", The level of the interrupt pin.
745 +
746 +**Exti_status: **80 (H): (0x80&0x01)=0  "False", Normal uplink packet.
747 +
748 +
749 +=== 2.8.2 Set the Report on Change ===
750 +
751 +
752 +Feature: Set the detection interval and threshold to monitor whether the IDC/VDC variable exceeds the threshold. If the threshold is exceeded, an ROC uplink is sent.
753 +(% style="color:blue" %)**AT Command: AT+ROC**
754 +
755 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
756 +|=(% style="width: 143px; background-color: rgb(79, 129, 189); color: white;" %)**Command Example**|=(% style="width: 197px; background-color: rgb(79, 129, 189); color: white;" %)**Parameters**|=(% style="width: 168px; background-color: rgb(79, 129, 189); color: white;" %)**Response/Explanation**
757 +|(% style="width:143px" %)AT+ROC=?|(% style="width:197px" %)Show current ROC setting|(% style="width:168px" %)(((
758 +0,0,0,0(default)
759 +
760 +OK
761 +)))
762 +|(% colspan="1" rowspan="4" style="width:143px" %)(((
763 +
764 +
765 +
766 +
767 +AT+ROC=a,b,c,d
768 +)))|(% style="width:197px" %)**a**: Enable or disable the ROC|(% style="width:168px" %)(((
769 +0: off
770 +
771 +1: on
772 +)))
773 +|(% style="width:197px" %)**b**: Set the detection interval|(% style="width:168px" %)Unit: second
774 +|(% style="width:197px" %)**c**: Setting the IDC change threshold|(% style="width:168px" %)Unit: uA
775 +|(% style="width:197px" %)**d**: Setting the VDC change threshold|(% style="width:168px" %)Unit: mV
776 +
777 +**Example:**
778 +
779 +* AT+ROC=1,60,3000, 500  ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA) or VDC (>500mV), sends an ROC uplink.
780 +* AT+ROC=1,60,3000,0  ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink. 0 Means doesn't monitor Voltage.
781 +
782 +(% style="color:blue" %)**Downlink Command: 0x09 aa bb cc dd**
783 +
784 +Format: Function code (0x09) followed by 4 bytes.
785 +
786 +(% style="color:blue" %)**aa: **(%%)Enable/Disable the ROC.
787 +
788 +(% style="color:blue" %)**bb: **(%%)Set the detection interval. (second)
789 +
790 +(% style="color:blue" %)**cc: **(%%)Setting the IDC change threshold. (uA)
791 +
792 +(% style="color:blue" %)**dd: **(%%)Setting the VDC change threshold. (mV)
793 +
794 +**Example:**
795 +
796 +* Downlink Payload: **09 01 00 3C 0B B8 01 F4 ** ~/~/Equal to AT+ROC=1,60,3000, 500
797 +* Downlink Payload: **09 01 00 3C 0B B8 00 00 ** ~/~/AT+ROC=1,60,3000,0
798 +
799 +(% style="color:blue" %)**Screenshot of parsing example in TTN:**
800 +
801 +* AT+ROC=1,60,3000, 500.
802 +
803 +[[image:image-20241019170902-1.png||height="450" width="1454"]]
804 +
805 +
806 +== 2.9 ​Firmware Change Log ==
807 +
808 +
678 678  **Firmware download link:**
679 679  
680 680  [[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]]
... ... @@ -1026,4 +1026,3 @@
1026 1026  
1027 1027  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]].
1028 1028  
1029 -
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0