Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/19 17:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.ting - Content
-
... ... @@ -647,6 +647,7 @@ 647 647 )))|(% style="background-color:#f2f2f2; width:150px" %)**1byte** 648 648 |(% style="background-color:#f2f2f2; width:70px" %)31|(% style="background-color:#f2f2f2; width:140px" %)Timestamp start|(% style="background-color:#f2f2f2; width:140px" %)Timestamp end|(% style="background-color:#f2f2f2; width:150px" %)Uplink Interval 649 649 650 + 650 650 Timestamp start and Timestamp end-use Unix TimeStamp format as mentioned above. Devices will reply with all data logs during this period, using the uplink interval. 651 651 652 652 For example, downlink command[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/image-20220518162852-1.png?rev=1.1||alt="image-20220518162852-1.png"]] ... ... @@ -855,12 +855,6 @@ 855 855 856 856 (A->01,B->02,C->03,D->04,E->05,F->06,G->07,H->08,I->09,J->0A,K->0B,L->0C) 857 857 858 -When aa=02, it is the Differential Pressure Sensor , which converts the current into a pressure value; 859 - 860 -bb represents which type of pressure sensor it is. 861 - 862 -(0~~100Pa->01,0~~200Pa->02,0~~300Pa->03,0~~1KPa->04,0~~2KPa->05,0~~3KPa->06,0~~4KPa->07,0~~5KPa->08,0~~10KPa->09,-100~~ 100Pa->0A,-200~~ 200Pa->0B,-1~~ 1KPa->0C) 863 - 864 864 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 865 865 |(% style="background-color:#4f81bd; color:white; width:154px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:269px" %)**Function**|(% style="background-color:#4f81bd; color:white" %)**Response** 866 866 |(% style="background-color:#f2f2f2; width:154px" %)AT+PROBE=?|(% style="background-color:#f2f2f2; width:269px" %)Get or Set the probe model.|(% style="background-color:#f2f2f2" %)0 ... ... @@ -883,7 +883,7 @@ 883 883 === 3.3.5 Multiple collections are one uplink (Since firmware V1.1) === 884 884 885 885 886 -Added AT+STDC command to collect the voltage of VDC_INPUT /IDC_INPUTmultiple times and upload it at one time.881 +Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time. 887 887 888 888 (% style="color:blue" %)**AT Command: AT** **+STDC** 889 889 ... ... @@ -891,8 +891,7 @@ 891 891 892 892 (% style="color:#037691" %)**aa:**(%%) 893 893 **0:** means disable this function and use TDC to send packets. 894 -**1:** means that the function is enabled to send packets by collecting VDC data for multiple times. 895 -**2:** means that the function is enabled to send packets by collecting IDC data for multiple times. 889 +**1:** means enable this function, use the method of multiple acquisitions to send packets. 896 896 (% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535 897 897 (% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120 898 898 ... ... @@ -917,7 +917,7 @@ 917 917 918 918 (% style="color:blue" %)**Downlink Command: 0xAE** 919 919 920 -Format: Command Code (0x AE) followed by4bytes.914 +Format: Command Code (0x08) followed by 5 bytes. 921 921 922 922 * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 923 923 ... ... @@ -1003,7 +1003,6 @@ 1003 1003 1004 1004 [[image:image-20240109172423-7.png]](% style="display:none" %) 1005 1005 1006 -[[image:image-20240817150702-1.png]] 1007 1007 1008 1008 = 9. Packing Info = 1009 1009
- image-20240817150702-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -38.4 KB - Content