Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/19 17:58
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -647,6 +647,7 @@ 647 647 )))|(% style="background-color:#f2f2f2; width:150px" %)**1byte** 648 648 |(% style="background-color:#f2f2f2; width:70px" %)31|(% style="background-color:#f2f2f2; width:140px" %)Timestamp start|(% style="background-color:#f2f2f2; width:140px" %)Timestamp end|(% style="background-color:#f2f2f2; width:150px" %)Uplink Interval 649 649 650 + 650 650 Timestamp start and Timestamp end-use Unix TimeStamp format as mentioned above. Devices will reply with all data logs during this period, using the uplink interval. 651 651 652 652 For example, downlink command[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/image-20220518162852-1.png?rev=1.1||alt="image-20220518162852-1.png"]] ... ... @@ -877,7 +877,7 @@ 877 877 === 3.3.5 Multiple collections are one uplink (Since firmware V1.1) === 878 878 879 879 880 -Added AT+STDC command to collect the voltage of VDC_INPUT /IDC_INPUTmultiple times and upload it at one time.881 +Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time. 881 881 882 882 (% style="color:blue" %)**AT Command: AT** **+STDC** 883 883 ... ... @@ -885,8 +885,7 @@ 885 885 886 886 (% style="color:#037691" %)**aa:**(%%) 887 887 **0:** means disable this function and use TDC to send packets. 888 -**1:** means that the function is enabled to send packets by collecting VDC data for multiple times. 889 -**2:** means that the function is enabled to send packets by collecting IDC data for multiple times. 889 +**1:** means enable this function, use the method of multiple acquisitions to send packets. 890 890 (% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535 891 891 (% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120 892 892 ... ... @@ -911,7 +911,7 @@ 911 911 912 912 (% style="color:blue" %)**Downlink Command: 0xAE** 913 913 914 -Format: Command Code (0x AE) followed by4bytes.914 +Format: Command Code (0x08) followed by 5 bytes. 915 915 916 916 * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 917 917