Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/19 17:58
Change comment:
Uploaded new attachment "image-20240513100129-6.png", version {1}
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -146,18 +146,20 @@ 146 146 * Operating temperature: 0℃~~50℃ 147 147 * Material: 316 stainless steels 148 148 149 + 149 149 === 1.4.3 Wireless Differential Air Pressure Sensor === 150 150 151 151 [[image:image-20240511174954-1.png]] 152 152 153 -* Measuring Range: -100KPa~~0~~100KPa (Optional measuringrange).154 +* Measuring Range: -100KPa~~0~~100KPa,Intermediate range is optional. 154 154 * Accuracy: 0.5% F.S, resolution is 0.05%. 155 155 * Overload: 300% F.S 156 156 * Zero temperature drift: ±0.03%F.S/°C 157 -* Operating temperature: -20℃~~60℃ 158 -* Storage temperature: -20℃~~60℃ 158 +* Operating temperature: -40℃~~85℃ 159 159 * Compensation temperature: 0~~50°C 160 160 161 + 162 + 161 161 == 1.5 Application and Installation == 162 162 163 163 === 1.5.1 Thread Installation Type === ... ... @@ -188,7 +188,7 @@ 188 188 [[image:1675071725288-579.png]] 189 189 190 190 191 - Below is the wiring to for connect the probe to the device.193 +The Immersion Type pressure sensor is shipped with the probe and device separately. When user got the device, below is the wiring to for connect the probe to the device. 192 192 193 193 The Immersion Type Sensor has different variant which defined by Ixx. For example, this means two points: 194 194 ... ... @@ -201,31 +201,6 @@ 201 201 [[image:1675071776102-240.png]] 202 202 203 203 204 - 205 -=== 1.5.3 Wireless Differential Air Pressure Sensor === 206 - 207 - 208 -(% style="color:blue" %)**Application:** 209 - 210 -Indoor Air Control & Filter clogging Detect. 211 - 212 -[[image:image-20240513100129-6.png]] 213 - 214 -[[image:image-20240513100135-7.png]] 215 - 216 - 217 -Below is the wiring to for connect the probe to the device. 218 - 219 -[[image:image-20240513093957-1.png]] 220 - 221 - 222 -Size of wind pressure transmitter: 223 - 224 -[[image:image-20240513094047-2.png]] 225 - 226 -Note: The above dimensions are measured by hand, and the numerical error of the shell is within ±0.2mm. 227 - 228 - 229 229 == 1.6 Sleep mode and working mode == 230 230 231 231 ... ... @@ -591,88 +591,15 @@ 591 591 [[image:1675145081239-376.png]] 592 592 593 593 594 -== 2.6 DatalogFeature(SinceV1.1)==571 +== 2.6 Frequency Plans == 595 595 596 -When a user wants to retrieve sensor value, he can send a poll command from the IoT platform to ask the sensor to send value in the required time slot. 597 597 598 - 599 - 600 -=== 2.6.1 Unix TimeStamp === 601 - 602 -CPL01 uses Unix TimeStamp format based on 603 - 604 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652861618065-927.png?width=705&height=109&rev=1.1||alt="1652861618065-927.png" height="109" width="705"]] 605 - 606 -Users can get this time from the link: [[https:~~/~~/www.epochconverter.com/>>url:https://www.epochconverter.com/]] : 607 - 608 -Below is the converter example: 609 - 610 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652861637105-371.png?width=732&height=428&rev=1.1||alt="1652861637105-371.png"]] 611 - 612 - 613 -=== 2.6.2 Set Device Time === 614 - 615 -There are two ways to set the device's time: 616 - 617 - 618 -(% style="color:blue" %)**1. Through LoRaWAN MAC Command (Default settings)** 619 - 620 -Users need to set SYNCMOD=1 to enable sync time via the MAC command. 621 - 622 -Once CPL01 Joined the LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to CPL01. If CPL01 fails to get the time from the server, CPL01 will use the internal time and wait for the next time request ~[[[via Device Status (FPORT=5)>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.1DeviceStatus2CFPORT3D5]]]. 623 - 624 - 625 -(% style="color:red" %)**Note: LoRaWAN Server needs to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature.** 626 - 627 - 628 -(% style="color:blue" %)** 2. Manually Set Time** 629 - 630 -Users need to set SYNCMOD=0 to manual time, otherwise, the user set time will be overwritten by the time set by the server. 631 - 632 - 633 -=== 2.6.3 Poll sensor value === 634 - 635 -Users can poll sensor values based on timestamps. Below is the downlink command. 636 - 637 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:470px" %) 638 -|=(% colspan="4" style="width: 154px;background-color:#4F81BD;color:white" %)**Downlink Command to poll Open/Close status (0x31)** 639 -|(% style="background-color:#f2f2f2; width:70px" %)**1byte**|(% style="background-color:#f2f2f2; width:140px" %)**4bytes**|(% style="background-color:#f2f2f2; width:140px" %)((( 640 -((( 641 -**4bytes** 642 -))) 643 - 644 -((( 645 - 646 -))) 647 -)))|(% style="background-color:#f2f2f2; width:150px" %)**1byte** 648 -|(% style="background-color:#f2f2f2; width:70px" %)31|(% style="background-color:#f2f2f2; width:140px" %)Timestamp start|(% style="background-color:#f2f2f2; width:140px" %)Timestamp end|(% style="background-color:#f2f2f2; width:150px" %)Uplink Interval 649 - 650 -Timestamp start and Timestamp end-use Unix TimeStamp format as mentioned above. Devices will reply with all data logs during this period, using the uplink interval. 651 - 652 -For example, downlink command[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/image-20220518162852-1.png?rev=1.1||alt="image-20220518162852-1.png"]] 653 - 654 -Is to check 2021/11/12 12:00:00 to 2021/11/12 15:00:00's data 655 - 656 -Uplink Internal =5s,means CPL01 will send one packet every 5s. range 5~~255s. 657 - 658 - 659 -=== 2.6.4 Decoder in TTN V3 === 660 - 661 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652862574387-195.png?width=722&height=359&rev=1.1||alt="1652862574387-195.png" height="359" width="722"]] 662 - 663 -Please check the decoder from this link: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>url:https://github.com/dragino/dragino-end-node-decoder]] 664 - 665 - 666 - 667 -== 2.7 Frequency Plans == 668 - 669 - 670 670 The PS-LB/LS uses OTAA mode and below frequency plans by default. Each frequency band use different firmware, user update the firmware to the corresponding band for their country. 671 671 672 672 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 673 673 674 674 675 -== 2. 8Firmware Change Log ==579 +== 2.7 Firmware Change Log == 676 676 677 677 678 678 **Firmware download link:** ... ... @@ -877,7 +877,7 @@ 877 877 === 3.3.5 Multiple collections are one uplink (Since firmware V1.1) === 878 878 879 879 880 -Added AT+STDC command to collect the voltage of VDC_INPUT /IDC_INPUTmultiple times and upload it at one time.784 +Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time. 881 881 882 882 (% style="color:blue" %)**AT Command: AT** **+STDC** 883 883 ... ... @@ -885,8 +885,7 @@ 885 885 886 886 (% style="color:#037691" %)**aa:**(%%) 887 887 **0:** means disable this function and use TDC to send packets. 888 -**1:** means that the function is enabled to send packets by collecting VDC data for multiple times. 889 -**2:** means that the function is enabled to send packets by collecting IDC data for multiple times. 792 +**1:** means enable this function, use the method of multiple acquisitions to send packets. 890 890 (% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535 891 891 (% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120 892 892 ... ... @@ -911,7 +911,7 @@ 911 911 912 912 (% style="color:blue" %)**Downlink Command: 0xAE** 913 913 914 -Format: Command Code (0x AE) followed by4bytes.817 +Format: Command Code (0x08) followed by 5 bytes. 915 915 916 916 * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 917 917
- image-20240513100135-7.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -98.0 KB - Content