From version < 93.1 >
edited by Mengting Qiu
on 2024/05/31 12:00
To version < 97.1 >
edited by Xiaoling
on 2024/09/26 14:13
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.ting
1 +XWiki.Xiaoling
Content
... ... @@ -41,7 +41,7 @@
41 41  )))
42 42  
43 43  (((
44 -PS-LB/LS is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery **(%%)or (% style="color:blue" %)**solar powered + li-on battery **(%%), it is designed for long term use up to 5 years.
44 +PS-LB/LS is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery **(%%)or (% style="color:blue" %)**solar powered + Li-ion battery **(%%), it is designed for long term use up to 5 years.
45 45  )))
46 46  
47 47  (((
... ... @@ -67,7 +67,7 @@
67 67  * Downlink to change configure
68 68  * Controllable 3.3v,5v and 12v output to power external sensor
69 69  * 8500mAh Li/SOCl2 Battery (PS-LB)
70 -* Solar panel + 3000mAh Li-on battery (PS-LS)
70 +* Solar panel + 3000mAh Li-ion battery (PS-LS)
71 71  
72 72  == 1.3 Specification ==
73 73  
... ... @@ -647,7 +647,6 @@
647 647  )))|(% style="background-color:#f2f2f2; width:150px" %)**1byte**
648 648  |(% style="background-color:#f2f2f2; width:70px" %)31|(% style="background-color:#f2f2f2; width:140px" %)Timestamp start|(% style="background-color:#f2f2f2; width:140px" %)Timestamp end|(% style="background-color:#f2f2f2; width:150px" %)Uplink Interval
649 649  
650 -
651 651  Timestamp start and Timestamp end-use Unix TimeStamp format as mentioned above. Devices will reply with all data logs during this period, using the uplink interval.
652 652  
653 653  For example, downlink command[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/image-20220518162852-1.png?rev=1.1||alt="image-20220518162852-1.png"]]
... ... @@ -856,6 +856,12 @@
856 856  
857 857  (A->01,B->02,C->03,D->04,E->05,F->06,G->07,H->08,I->09,J->0A,K->0B,L->0C)
858 858  
858 +When aa=02, it is the Differential Pressure Sensor , which converts the current into a pressure value;
859 +
860 +bb represents which type of pressure sensor it is.
861 +
862 +(0~~100Pa->01,0~~200Pa->02,0~~300Pa->03,0~~1KPa->04,0~~2KPa->05,0~~3KPa->06,0~~4KPa->07,0~~5KPa->08,0~~10KPa->09,-100~~ 100Pa->0A,-200~~ 200Pa->0B,-1~~ 1KPa->0C)
863 +
859 859  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
860 860  |(% style="background-color:#4f81bd; color:white; width:154px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:269px" %)**Function**|(% style="background-color:#4f81bd; color:white" %)**Response**
861 861  |(% style="background-color:#f2f2f2; width:154px" %)AT+PROBE=?|(% style="background-color:#f2f2f2; width:269px" %)Get or Set the probe model.|(% style="background-color:#f2f2f2" %)0
... ... @@ -878,7 +878,7 @@
878 878  === 3.3.5 Multiple collections are one uplink (Since firmware V1.1) ===
879 879  
880 880  
881 -Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time.
886 +Added AT+STDC command to collect the voltage of VDC_INPUT/IDC_INPUT multiple times and upload it at one time.
882 882  
883 883  (% style="color:blue" %)**AT Command: AT** **+STDC**
884 884  
... ... @@ -886,7 +886,8 @@
886 886  
887 887  (% style="color:#037691" %)**aa:**(%%)
888 888  **0:** means disable this function and use TDC to send packets.
889 -**1:** means enable this function, use the method of multiple acquisitions to send packets.
894 +**1:** means that the function is enabled to send packets by collecting VDC data for multiple times.
895 +**2:** means that the function is enabled to send packets by collecting IDC data for multiple times.
890 890  (% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535
891 891  (% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120
892 892  
... ... @@ -911,7 +911,7 @@
911 911  
912 912  (% style="color:blue" %)**Downlink Command: 0xAE**
913 913  
914 -Format: Command Code (0x08) followed by 5 bytes.
920 +Format: Command Code (0xAE) followed by 4 bytes.
915 915  
916 916  * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->**  AT+STDC=1,600,18
917 917  
... ... @@ -997,6 +997,7 @@
997 997  
998 998  [[image:image-20240109172423-7.png]](% style="display:none" %)
999 999  
1006 +[[image:image-20240817150702-1.png]]
1000 1000  
1001 1001  = 9. ​Packing Info =
1002 1002  
image-20240817150702-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +38.4 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0