... ... @@ -155,6 +155,7 @@
155 155  * Overload: 300% F.S
156 156  * Zero temperature drift: ±0.03%F.S/°C
157 157  * Operating temperature: -20℃~~60℃
158 +* Storage temperature:  -20℃~~60℃
158 158  * Compensation temperature: 0~~50°C
159 159  
160 160  == 1.5 Application and Installation ==
... ... @@ -590,15 +590,88 @@
590 590  [[image:1675145081239-376.png]]
591 591  
592 592  
593 -== 2.6 Frequency Plans ==
594 +== 2.6 Datalog Feature (Since V1.1) ==
594 594  
596 +When a user wants to retrieve sensor value, he can send a poll command from the IoT platform to ask the sensor to send value in the required time slot.
595 595  
598 +
599 +
600 +=== 2.6.1 Unix TimeStamp ===
601 +
602 +CPL01 uses Unix TimeStamp format based on
603 +
604 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652861618065-927.png?width=705&height=109&rev=1.1||alt="1652861618065-927.png" height="109" width="705"]]
605 +
606 +Users can get this time from the link:  [[https:~~/~~/www.epochconverter.com/>>url:https://www.epochconverter.com/]] :
607 +
608 +Below is the converter example:
609 +
610 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652861637105-371.png?width=732&height=428&rev=1.1||alt="1652861637105-371.png"]]
611 +
612 +
613 +=== 2.6.2 Set Device Time ===
614 +
615 +There are two ways to set the device's time:
616 +
617 +
618 +(% style="color:blue" %)**1. Through LoRaWAN MAC Command (Default settings)**
619 +
620 +Users need to set SYNCMOD=1 to enable sync time via the MAC command.
621 +
622 +Once CPL01 Joined the LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to CPL01. If CPL01 fails to get the time from the server, CPL01 will use the internal time and wait for the next time request ~[[[via Device Status (FPORT=5)>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.1DeviceStatus2CFPORT3D5]]].
623 +
624 +
625 +(% style="color:red" %)**Note: LoRaWAN Server needs to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature.**
626 +
627 +
628 +(% style="color:blue" %)** 2. Manually Set Time**
629 +
630 +Users need to set SYNCMOD=0 to manual time, otherwise, the user set time will be overwritten by the time set by the server.
631 +
632 +
633 +=== 2.6.3 Poll sensor value ===
634 +
635 +Users can poll sensor values based on timestamps. Below is the downlink command.
636 +
637 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:470px" %)
638 +|=(% colspan="4" style="width: 154px;background-color:#4F81BD;color:white" %)**Downlink Command to poll Open/Close status (0x31)**
639 +|(% style="background-color:#f2f2f2; width:70px" %)**1byte**|(% style="background-color:#f2f2f2; width:140px" %)**4bytes**|(% style="background-color:#f2f2f2; width:140px" %)(((
640 +(((
641 +**4bytes**
642 +)))
643 +
644 +(((
645 +
646 +)))
647 +)))|(% style="background-color:#f2f2f2; width:150px" %)**1byte**
648 +|(% style="background-color:#f2f2f2; width:70px" %)31|(% style="background-color:#f2f2f2; width:140px" %)Timestamp start|(% style="background-color:#f2f2f2; width:140px" %)Timestamp end|(% style="background-color:#f2f2f2; width:150px" %)Uplink Interval
649 +
650 +Timestamp start and Timestamp end-use Unix TimeStamp format as mentioned above. Devices will reply with all data logs during this period, using the uplink interval.
651 +
652 +For example, downlink command[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/image-20220518162852-1.png?rev=1.1||alt="image-20220518162852-1.png"]]
653 +
654 +Is to check 2021/11/12 12:00:00 to 2021/11/12 15:00:00's data
655 +
656 +Uplink Internal =5s,means CPL01 will send one packet every 5s. range 5~~255s.
657 +
658 +
659 +=== 2.6.4 Decoder in TTN V3 ===
660 +
661 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652862574387-195.png?width=722&height=359&rev=1.1||alt="1652862574387-195.png" height="359" width="722"]]
662 +
663 +Please check the decoder from this link: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>url:https://github.com/dragino/dragino-end-node-decoder]]
664 +
665 +
666 +
667 +== 2.7 Frequency Plans ==
668 +
669 +
596 596  The PS-LB/LS uses OTAA mode and below frequency plans by default. Each frequency band use different firmware, user update the firmware to the corresponding band for their country.
597 597  
598 598  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
599 599  
600 600  
601 -== 2.7 ​Firmware Change Log ==
675 +== 2.8 ​Firmware Change Log ==
602 602  
603 603  
604 604  **Firmware download link:**
... ... @@ -803,7 +803,7 @@
803 803  === 3.3.5 Multiple collections are one uplink (Since firmware V1.1) ===
804 804  
805 805  
806 -Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time.
880 +Added AT+STDC command to collect the voltage of VDC_INPUT/IDC_INPUT multiple times and upload it at one time.
807 807  
808 808  (% style="color:blue" %)**AT Command: AT** **+STDC**
809 809  
... ... @@ -811,7 +811,8 @@
811 811  
812 812  (% style="color:#037691" %)**aa:**(%%)
813 813  **0:** means disable this function and use TDC to send packets.
814 -**1:** means enable this function, use the method of multiple acquisitions to send packets.
888 +**1:** means that the function is enabled to send packets by collecting VDC data for multiple times.
889 +**2:** means that the function is enabled to send packets by collecting IDC data for multiple times.
815 815  (% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535
816 816  (% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120
817 817  
... ... @@ -836,7 +836,7 @@
836 836  
837 837  (% style="color:blue" %)**Downlink Command: 0xAE**
838 838  
839 -Format: Command Code (0x08) followed by 5 bytes.
914 +Format: Command Code (0xAE) followed by 4 bytes.
840 840  