Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/19 17:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. ting1 +XWiki.Xiaoling - Content
-
... ... @@ -41,7 +41,7 @@ 41 41 ))) 42 42 43 43 ((( 44 -PS-LB/LS is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery **(%%)or (% style="color:blue" %)**solar powered + li-on battery **(%%), it is designed for long term use up to 5 years.44 +PS-LB/LS is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery **(%%)or (% style="color:blue" %)**solar powered + Li-ion battery **(%%), it is designed for long term use up to 5 years. 45 45 ))) 46 46 47 47 ((( ... ... @@ -67,7 +67,7 @@ 67 67 * Downlink to change configure 68 68 * Controllable 3.3v,5v and 12v output to power external sensor 69 69 * 8500mAh Li/SOCl2 Battery (PS-LB) 70 -* Solar panel + 3000mAh Li-on battery (PS-LS) 70 +* Solar panel + 3000mAh Li-ion battery (PS-LS) 71 71 72 72 == 1.3 Specification == 73 73 ... ... @@ -136,14 +136,14 @@ 136 136 === 1.4.2 Immersion Type === 137 137 138 138 139 -[[image:image-20240109160445-5.png||height="2 84" width="214"]]139 +[[image:image-20240109160445-5.png||height="221" width="166"]] 140 140 141 141 * Immersion Type, Probe IP Level: IP68 142 142 * Measuring Range: Measure range can be customized, up to 100m. 143 143 * Accuracy: 0.2% F.S 144 144 * Long-Term Stability: ±0.2% F.S / Year 145 -* Storage temperature: -30 ℃~~80℃146 -* Operating temperature: 0 ℃~~50℃145 +* Storage temperature: -30°C~~80°C 146 +* Operating temperature: 0°C~~50°C 147 147 * Material: 316 stainless steels 148 148 149 149 === 1.4.3 Wireless Differential Air Pressure Sensor === ... ... @@ -150,14 +150,14 @@ 150 150 151 151 [[image:image-20240511174954-1.png]] 152 152 153 -* Measuring Range: -100KPa~~0~~100KPa ,Intermediate rangeis optional.153 +* Measuring Range: -100KPa~~0~~100KPa(Optional measuring range). 154 154 * Accuracy: 0.5% F.S, resolution is 0.05%. 155 155 * Overload: 300% F.S 156 156 * Zero temperature drift: ±0.03%F.S/°C 157 -* Operating temperature: -40℃~~85℃ 157 +* Operating temperature: -20°C~~60°C 158 +* Storage temperature: -20°C~~60°C 158 158 * Compensation temperature: 0~~50°C 159 159 160 - 161 161 == 1.5 Application and Installation == 162 162 163 163 === 1.5.1 Thread Installation Type === ... ... @@ -188,7 +188,7 @@ 188 188 [[image:1675071725288-579.png]] 189 189 190 190 191 - TheImmersion Type pressure sensor is shipped with the probe and device separately. When user got the device, below is the wiring to for connect the probe to the device.191 +Below is the wiring to for connect the probe to the device. 192 192 193 193 The Immersion Type Sensor has different variant which defined by Ixx. For example, this means two points: 194 194 ... ... @@ -214,7 +214,7 @@ 214 214 [[image:image-20240513100135-7.png]] 215 215 216 216 217 - TheWireless Differential Air Pressure Sensor is shippedwiththe probe and deviceseparately.When user gotthedevice, belows the wiring to for connect the probe to the device.217 +Below is the wiring to for connect the probe to the device. 218 218 219 219 [[image:image-20240513093957-1.png]] 220 220 ... ... @@ -226,9 +226,6 @@ 226 226 Note: The above dimensions are measured by hand, and the numerical error of the shell is within ±0.2mm. 227 227 228 228 229 - 230 - 231 - 232 232 == 1.6 Sleep mode and working mode == 233 233 234 234 ... ... @@ -278,7 +278,7 @@ 278 278 279 279 == 1.10 Mechanical == 280 280 281 -=== 1.10.1 for LB version (%style="display:none" %) (%%)===278 +=== 1.10.1 for LB version === 282 282 283 283 284 284 [[image:image-20240109160800-6.png]] ... ... @@ -594,17 +594,219 @@ 594 594 [[image:1675145081239-376.png]] 595 595 596 596 597 -== 2.6 F requencyPlans==594 +== 2.6 Datalog Feature (Since V1.1) == 598 598 596 +When a user wants to retrieve sensor value, he can send a poll command from the IoT platform to ask the sensor to send value in the required time slot. 599 599 598 + 599 + 600 +=== 2.6.1 Unix TimeStamp === 601 + 602 +CPL01 uses Unix TimeStamp format based on 603 + 604 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652861618065-927.png?width=705&height=109&rev=1.1||alt="1652861618065-927.png" height="109" width="705"]] 605 + 606 +Users can get this time from the link: [[https:~~/~~/www.epochconverter.com/>>url:https://www.epochconverter.com/]] : 607 + 608 +Below is the converter example: 609 + 610 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652861637105-371.png?width=732&height=428&rev=1.1||alt="1652861637105-371.png"]] 611 + 612 + 613 +=== 2.6.2 Set Device Time === 614 + 615 +There are two ways to set the device's time: 616 + 617 + 618 +(% style="color:blue" %)**1. Through LoRaWAN MAC Command (Default settings)** 619 + 620 +Users need to set SYNCMOD=1 to enable sync time via the MAC command. 621 + 622 +Once CPL01 Joined the LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to CPL01. If CPL01 fails to get the time from the server, CPL01 will use the internal time and wait for the next time request ~[[[via Device Status (FPORT=5)>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.1DeviceStatus2CFPORT3D5]]]. 623 + 624 + 625 +(% style="color:red" %)**Note: LoRaWAN Server needs to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature.** 626 + 627 + 628 +(% style="color:blue" %)** 2. Manually Set Time** 629 + 630 +Users need to set SYNCMOD=0 to manual time, otherwise, the user set time will be overwritten by the time set by the server. 631 + 632 + 633 +=== 2.6.3 Poll sensor value === 634 + 635 +Users can poll sensor values based on timestamps. Below is the downlink command. 636 + 637 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:470px" %) 638 +|=(% colspan="4" style="width: 154px;background-color:#4F81BD;color:white" %)**Downlink Command to poll Open/Close status (0x31)** 639 +|(% style="background-color:#f2f2f2; width:70px" %)**1byte**|(% style="background-color:#f2f2f2; width:140px" %)**4bytes**|(% style="background-color:#f2f2f2; width:140px" %)((( 640 +((( 641 +**4bytes** 642 +))) 643 + 644 + 645 +)))|(% style="background-color:#f2f2f2; width:150px" %)**1byte** 646 +|(% style="background-color:#f2f2f2; width:70px" %)31|(% style="background-color:#f2f2f2; width:140px" %)Timestamp start|(% style="background-color:#f2f2f2; width:140px" %)Timestamp end|(% style="background-color:#f2f2f2; width:150px" %)Uplink Interval 647 + 648 +Timestamp start and Timestamp end-use Unix TimeStamp format as mentioned above. Devices will reply with all data logs during this period, using the uplink interval. 649 + 650 +For example, downlink command[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/image-20220518162852-1.png?rev=1.1||alt="image-20220518162852-1.png"]] 651 + 652 +Is to check 2021/11/12 12:00:00 to 2021/11/12 15:00:00's data 653 + 654 +Uplink Internal =5s,means CPL01 will send one packet every 5s. range 5~~255s. 655 + 656 + 657 +=== 2.6.4 Decoder in TTN V3 === 658 + 659 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652862574387-195.png?width=722&height=359&rev=1.1||alt="1652862574387-195.png" height="359" width="722"]] 660 + 661 +Please check the decoder from this link: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>url:https://github.com/dragino/dragino-end-node-decoder]] 662 + 663 + 664 + 665 +== 2.7 Frequency Plans == 666 + 667 + 600 600 The PS-LB/LS uses OTAA mode and below frequency plans by default. Each frequency band use different firmware, user update the firmware to the corresponding band for their country. 601 601 602 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 670 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/a>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 603 603 604 604 605 -== 2. 7Firmware ChangeLog==673 +== 2.8 Report on Change Feature (Since firmware V1.1.2) == 606 606 607 607 676 +=== 2.8.1 Uplink payload(Enable ROC) === 677 + 678 + 679 +Used to Monitor the IDC and VDC increments, and send ROC uplink when the IDC or VDC changes exceed. 680 + 681 +With ROC enabled, the payload is as follows: 682 + 683 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 684 +|(% style="background-color:#4f81bd; color:white; width:97px" %)((( 685 +**Size(bytes)** 686 +)))|(% style="background-color:#4f81bd; color:white; width:48px" %)**2**|(% style="background-color:#4f81bd; color:white; width:71px" %)**2**|(% style="background-color:#4f81bd; color:white; width:98px" %)**2**|(% style="background-color:#4f81bd; color:white; width:73px" %)**2**|(% style="background-color:#4f81bd; color:white; width:122px" %)**1** 687 +|(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)((( 688 +[[IN1 &IN2 Interrupt flag>>||anchor="H2.3.7IN126IN226INTpin"]] 689 + 690 +& **ROC_flag** 691 +))) 692 + 693 +(% style="color:blue" %)**IN1 &IN2 , Interrupt flag , ROC_flag:** 694 + 695 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 696 +|(% style="background-color:#4f81bd; color:white; width:55px" %)**Size(bit)**|(% style="background-color:#4f81bd; color:white; width:65px" %)**bit7**|(% style="background-color:#4f81bd; color:white; width:46.5834px" %)**bit6**|(% style="background-color:#4f81bd; color:white; width:1px" %)**bit5**|(% style="background-color:#4f81bd; color:white; width:65px" %)**bit4**|(% style="background-color:#4f81bd; color:white; width:65px" %)**bit3**|(% style="background-color:#4f81bd; color:white; width:105px" %)**bit2**|(% style="background-color:#4f81bd; color:white; width:105px" %)**bit1**|(% style="background-color:#4f81bd; color:white; width:105px" %)**bit0** 697 +|(% style="width:75px" %)Value|(% style="width:89px" %)IDC_Roc_flagL|(% style="width:46.5834px" %)IDC_Roc_flagH|(% style="width:1px" %)VDC_Roc_flagL|(% style="width:89px" %)VDC_Roc_flagH|(% style="width:89px" %)IN1_pin_level|(% style="width:103px" %)IN2_pin_level|(% style="width:103px" %)Exti_pin_level|(% style="width:103px" %)Exti_status 698 + 699 +* (% style="color:#037691" %)**IDC_Roc_flagL** 700 + 701 +80 (H): (0x80&0x80)=80(H)=**1**000 0000(B) bit7=1, "TRUE", This uplink is triggered when the decrease in the IDC compared to the last ROC refresh exceeds the set threshold. 702 + 703 +60 (H): (0x60&0x80)=0 bit7=0, "FALSE", This uplink is not triggered when the decrease in the IDC compared to the last ROC refresh exceeds the set threshold. 704 + 705 + 706 +* (% style="color:#037691" %)**IDC_Roc_flagH** 707 + 708 +60 (H): (0x60&0x40)=60(H)=0**1**000 0000(B) bit6=1, "TRUE", This uplink is triggered when the increase in the value of the IDC compared to the last ROC refresh exceeds the set threshold. 709 + 710 +80 (H): (0x80&0x40)=0 bit6=0, "FALSE", This uplink is not triggered when the increase in the value of the IDC compared to the last ROC refresh exceeds the set threshold. 711 + 712 + 713 +* (% style="color:#037691" %)**VDC_Roc_flagL** 714 + 715 +20 (H): (0x20&0x20)=20(H)=00**1**0 0000(B) bit5=1, "TRUE", This uplink is triggered when the decrease in the VDC compared to the last ROC refresh exceeds the set threshold. 716 + 717 +90 (H): (0x90&0x20)=0 bit5=0, "FALSE", This uplink is not triggered when the decrease in the VDC compared to the last ROC refresh exceeds the set threshold. 718 + 719 + 720 +* (% style="color:#037691" %)**VDC_Roc_flagH** 721 + 722 +90 (H): (0x90&0x10)=10(H)=000**1** 0000(B) bit4=1, "TRUE", This uplink is triggered when the increase in the value of the VDC compared to the last ROC refresh exceeds the set threshold. 723 + 724 +20 (H): (0x20&0x10)=0 bit4=0, "FALSE", This uplink is not triggered when the increase in the value of the VDC compared to the last ROC refresh exceeds the set threshold. 725 + 726 + 727 +* (% style="color:#037691" %)**IN1_pin_level & IN2_pin_level** 728 + 729 +IN1 and IN2 are used as digital input pins. 730 + 731 +80 (H): (0x80&0x08)=0 IN1 pin is low level. 732 + 733 +80 (H): (0x09&0x04)=0 IN2 pin is low level. 734 + 735 + 736 +* (% style="color:#037691" %)**Exti_pin_level &Exti_status** 737 + 738 +This data field shows whether the packet is generated by an interrupt pin. 739 + 740 +Note: The Internet pin of the old motherboard is a separate pin in the screw terminal, and the interrupt pin of the new motherboard(SIB V1.3) is the **GPIO_EXTI** pin. 741 + 742 +**Exti_pin_level:** 80 (H): (0x80&0x02)=0 "low", The level of the interrupt pin. 743 + 744 +**Exti_status: **80 (H): (0x80&0x01)=0 "False", Normal uplink packet. 745 + 746 + 747 +=== 2.8.2 Set the Report on Change === 748 + 749 + 750 +Feature: Set the detection interval and threshold to monitor whether the IDC/VDC variable exceeds the threshold. If the threshold is exceeded, an ROC uplink is sent. 751 +(% style="color:blue" %)**AT Command: AT+ROC** 752 + 753 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 754 +|=(% style="width: 143px; background-color: rgb(79, 129, 189); color: white;" %)**Command Example**|=(% style="width: 197px; background-color: rgb(79, 129, 189); color: white;" %)**Parameters**|=(% style="width: 168px; background-color: rgb(79, 129, 189); color: white;" %)**Response/Explanation** 755 +|(% style="width:143px" %)AT+ROC=?|(% style="width:197px" %)Show current ROC setting|(% style="width:168px" %)((( 756 +0,0,0,0(default) 757 + 758 +OK 759 +))) 760 +|(% colspan="1" rowspan="4" style="width:143px" %)((( 761 + 762 + 763 + 764 + 765 +AT+ROC=a,b,c,d 766 +)))|(% style="width:197px" %)**a**: Enable or disable the ROC|(% style="width:168px" %)((( 767 +0: off 768 + 769 +1: on 770 +))) 771 +|(% style="width:197px" %)**b**: Set the detection interval|(% style="width:168px" %)Unit: second 772 +|(% style="width:197px" %)**c**: Setting the IDC change threshold|(% style="width:168px" %)Unit: uA 773 +|(% style="width:197px" %)**d**: Setting the VDC change threshold|(% style="width:168px" %)Unit: mV 774 + 775 +**Example:** 776 + 777 +* AT+ROC=1,60,3000, 500 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA) or VDC (>500mV), sends an ROC uplink. 778 +* AT+ROC=1,60,3000,0 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink. 0 Means doesn't monitor Voltage. 779 + 780 +(% style="color:blue" %)**Downlink Command: 0x09 aa bb cc dd** 781 + 782 +Format: Function code (0x09) followed by 4 bytes. 783 + 784 +(% style="color:blue" %)**aa: **(%%)Enable/Disable the ROC. 785 + 786 +(% style="color:blue" %)**bb: **(%%)Set the detection interval. (second) 787 + 788 +(% style="color:blue" %)**cc: **(%%)Setting the IDC change threshold. (uA) 789 + 790 +(% style="color:blue" %)**dd: **(%%)Setting the VDC change threshold. (mV) 791 + 792 +**Example:** 793 + 794 +* Downlink Payload: **09 01 00 3C 0B B8 01 F4 ** ~/~/Equal to AT+ROC=1,60,3000, 500 795 +* Downlink Payload: **09 01 00 3C 0B B8 00 00 ** ~/~/AT+ROC=1,60,3000,0 796 + 797 +(% style="color:blue" %)**Screenshot of parsing example in TTN:** 798 + 799 +* AT+ROC=1,60,3000, 500. 800 + 801 +[[image:image-20241019170902-1.png||height="450" width="1454"]] 802 + 803 + 804 +== 2.9 Firmware Change Log == 805 + 806 + 608 608 **Firmware download link:** 609 609 610 610 [[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]] ... ... @@ -785,6 +785,12 @@ 785 785 786 786 (A->01,B->02,C->03,D->04,E->05,F->06,G->07,H->08,I->09,J->0A,K->0B,L->0C) 787 787 987 +When aa=02, it is the Differential Pressure Sensor , which converts the current into a pressure value; 988 + 989 +bb represents which type of pressure sensor it is. 990 + 991 +(0~~100Pa->01,0~~200Pa->02,0~~300Pa->03,0~~1KPa->04,0~~2KPa->05,0~~3KPa->06,0~~4KPa->07,0~~5KPa->08,0~~10KPa->09,-100~~ 100Pa->0A,-200~~ 200Pa->0B,-1~~ 1KPa->0C) 992 + 788 788 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 789 789 |(% style="background-color:#4f81bd; color:white; width:154px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:269px" %)**Function**|(% style="background-color:#4f81bd; color:white" %)**Response** 790 790 |(% style="background-color:#f2f2f2; width:154px" %)AT+PROBE=?|(% style="background-color:#f2f2f2; width:269px" %)Get or Set the probe model.|(% style="background-color:#f2f2f2" %)0 ... ... @@ -807,7 +807,7 @@ 807 807 === 3.3.5 Multiple collections are one uplink (Since firmware V1.1) === 808 808 809 809 810 -Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time. 1015 +Added AT+STDC command to collect the voltage of VDC_INPUT/IDC_INPUT multiple times and upload it at one time. 811 811 812 812 (% style="color:blue" %)**AT Command: AT** **+STDC** 813 813 ... ... @@ -815,7 +815,8 @@ 815 815 816 816 (% style="color:#037691" %)**aa:**(%%) 817 817 **0:** means disable this function and use TDC to send packets. 818 -**1:** means enable this function, use the method of multiple acquisitions to send packets. 1023 +**1:** means that the function is enabled to send packets by collecting VDC data for multiple times. 1024 +**2:** means that the function is enabled to send packets by collecting IDC data for multiple times. 819 819 (% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535 820 820 (% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120 821 821 ... ... @@ -840,7 +840,7 @@ 840 840 841 841 (% style="color:blue" %)**Downlink Command: 0xAE** 842 842 843 -Format: Command Code (0x 08) followed by5bytes.1049 +Format: Command Code (0xAE) followed by 4 bytes. 844 844 845 845 * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 846 846 ... ... @@ -926,6 +926,7 @@ 926 926 927 927 [[image:image-20240109172423-7.png]](% style="display:none" %) 928 928 1135 +[[image:image-20240817150702-1.png]] 929 929 930 930 = 9. Packing Info = 931 931 ... ... @@ -948,4 +948,3 @@ 948 948 949 949 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]]. 950 950 951 -
- image-20240817150702-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.4 KB - Content