Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/19 17:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. ting1 +XWiki.Xiaoling - Content
-
... ... @@ -41,7 +41,7 @@ 41 41 ))) 42 42 43 43 ((( 44 -PS-LB/LS is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery **(%%)or (% style="color:blue" %)**solar powered + li-on battery **(%%), it is designed for long term use up to 5 years.44 +PS-LB/LS is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery **(%%)or (% style="color:blue" %)**solar powered + Li-ion battery **(%%), it is designed for long term use up to 5 years. 45 45 ))) 46 46 47 47 ((( ... ... @@ -67,7 +67,7 @@ 67 67 * Downlink to change configure 68 68 * Controllable 3.3v,5v and 12v output to power external sensor 69 69 * 8500mAh Li/SOCl2 Battery (PS-LB) 70 -* Solar panel + 3000mAh Li-on battery (PS-LS) 70 +* Solar panel + 3000mAh Li-ion battery (PS-LS) 71 71 72 72 == 1.3 Specification == 73 73 ... ... @@ -136,30 +136,28 @@ 136 136 === 1.4.2 Immersion Type === 137 137 138 138 139 -[[image:image-20240109160445-5.png||height="2 84" width="214"]]139 +[[image:image-20240109160445-5.png||height="221" width="166"]] 140 140 141 141 * Immersion Type, Probe IP Level: IP68 142 142 * Measuring Range: Measure range can be customized, up to 100m. 143 143 * Accuracy: 0.2% F.S 144 144 * Long-Term Stability: ±0.2% F.S / Year 145 -* Storage temperature: -30 ℃~~80℃146 -* Operating temperature: 0 ℃~~50℃145 +* Storage temperature: -30°C~~80°C 146 +* Operating temperature: 0°C~~50°C 147 147 * Material: 316 stainless steels 148 148 149 - 150 150 === 1.4.3 Wireless Differential Air Pressure Sensor === 151 151 152 152 [[image:image-20240511174954-1.png]] 153 153 154 -* Measuring Range: -100KPa~~0~~100KPa ,Intermediate rangeis optional.153 +* Measuring Range: -100KPa~~0~~100KPa(Optional measuring range). 155 155 * Accuracy: 0.5% F.S, resolution is 0.05%. 156 156 * Overload: 300% F.S 157 157 * Zero temperature drift: ±0.03%F.S/°C 158 -* Operating temperature: -40℃~~85℃ 157 +* Operating temperature: -20°C~~60°C 158 +* Storage temperature: -20°C~~60°C 159 159 * Compensation temperature: 0~~50°C 160 160 161 - 162 - 163 163 == 1.5 Application and Installation == 164 164 165 165 === 1.5.1 Thread Installation Type === ... ... @@ -190,7 +190,7 @@ 190 190 [[image:1675071725288-579.png]] 191 191 192 192 193 - TheImmersion Type pressure sensor is shipped with the probe and device separately. When user got the device, below is the wiring to for connect the probe to the device.191 +Below is the wiring to for connect the probe to the device. 194 194 195 195 The Immersion Type Sensor has different variant which defined by Ixx. For example, this means two points: 196 196 ... ... @@ -203,6 +203,31 @@ 203 203 [[image:1675071776102-240.png]] 204 204 205 205 204 + 205 +=== 1.5.3 Wireless Differential Air Pressure Sensor === 206 + 207 + 208 +(% style="color:blue" %)**Application:** 209 + 210 +Indoor Air Control & Filter clogging Detect. 211 + 212 +[[image:image-20240513100129-6.png]] 213 + 214 +[[image:image-20240513100135-7.png]] 215 + 216 + 217 +Below is the wiring to for connect the probe to the device. 218 + 219 +[[image:image-20240513093957-1.png]] 220 + 221 + 222 +Size of wind pressure transmitter: 223 + 224 +[[image:image-20240513094047-2.png]] 225 + 226 +Note: The above dimensions are measured by hand, and the numerical error of the shell is within ±0.2mm. 227 + 228 + 206 206 == 1.6 Sleep mode and working mode == 207 207 208 208 ... ... @@ -252,7 +252,7 @@ 252 252 253 253 == 1.10 Mechanical == 254 254 255 -=== 1.10.1 for LB version (%style="display:none" %) (%%)===278 +=== 1.10.1 for LB version === 256 256 257 257 258 258 [[image:image-20240109160800-6.png]] ... ... @@ -277,7 +277,6 @@ 277 277 278 278 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LPS8v2>>url:https://www.dragino.com/products/lora-lorawan-gateway/item/228-lps8v2.html]] as a LoRaWAN gateway in this example. 279 279 280 - 281 281 [[image:1675144005218-297.png]] 282 282 283 283 ... ... @@ -333,7 +333,6 @@ 333 333 334 334 Users can also use the downlink command(0x26 01) to ask PS-LB/LS to resend this uplink. 335 335 336 - 337 337 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 338 338 |(% colspan="6" style="background-color:#4f81bd; color:white" %)**Device Status (FPORT=5)** 339 339 |(% style="background-color:#f2f2f2; width:103px" %)**Size (bytes)**|(% style="background-color:#f2f2f2; width:72px" %)**1**|(% style="background-color:#f2f2f2" %)**2**|(% style="background-color:#f2f2f2; width:91px" %)**1**|(% style="background-color:#f2f2f2; width:86px" %)**1**|(% style="background-color:#f2f2f2; width:44px" %)**2** ... ... @@ -454,7 +454,7 @@ 454 454 [[image:image-20230225154759-1.png||height="408" width="741"]] 455 455 456 456 457 -=== 2.3.6 0~~30V value ( 478 +=== 2.3.6 0~~30V value (pin VDC_IN) === 458 458 459 459 460 460 Measure the voltage value. The range is 0 to 30V. ... ... @@ -510,7 +510,6 @@ 510 510 511 511 While using TTN network, you can add the payload format to decode the payload. 512 512 513 - 514 514 [[image:1675144839454-913.png]] 515 515 516 516 ... ... @@ -528,12 +528,10 @@ 528 528 529 529 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps: 530 530 531 - 532 532 (% style="color:blue" %)**Step 1: **(%%)Be sure that your device is programmed and properly connected to the network at this time. 533 533 534 534 (% style="color:blue" %)**Step 2:**(%%) To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps: 535 535 536 - 537 537 [[image:1675144951092-237.png]] 538 538 539 539 ... ... @@ -550,7 +550,6 @@ 550 550 [[image:1675145018212-853.png]] 551 551 552 552 553 - 554 554 [[image:1675145029119-717.png]] 555 555 556 556 ... ... @@ -564,21 +564,221 @@ 564 564 565 565 After added, the sensor data arrive TTN, it will also arrive and show in Datacake. 566 566 567 - 568 568 [[image:1675145081239-376.png]] 569 569 570 570 571 -== 2.6 F requencyPlans==587 +== 2.6 Datalog Feature (Since V1.1) == 572 572 573 573 590 +When a user wants to retrieve sensor value, he can send a poll command from the IoT platform to ask the sensor to send value in the required time slot. 591 + 592 + 593 +=== 2.6.1 Unix TimeStamp === 594 + 595 + 596 +CPL01 uses Unix TimeStamp format based on 597 + 598 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652861618065-927.png?width=705&height=109&rev=1.1||alt="1652861618065-927.png" height="109" width="705"]] 599 + 600 +Users can get this time from the link: [[https:~~/~~/www.epochconverter.com/>>url:https://www.epochconverter.com/]] : 601 + 602 +Below is the converter example: 603 + 604 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652861637105-371.png?width=732&height=428&rev=1.1||alt="1652861637105-371.png"]] 605 + 606 + 607 +=== 2.6.2 Set Device Time === 608 + 609 + 610 +There are two ways to set the device's time: 611 + 612 + 613 +(% style="color:blue" %)**1. Through LoRaWAN MAC Command (Default settings)** 614 + 615 +Users need to set SYNCMOD=1 to enable sync time via the MAC command. 616 + 617 +Once CPL01 Joined the LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to CPL01. If CPL01 fails to get the time from the server, CPL01 will use the internal time and wait for the next time request ~[[[via Device Status (FPORT=5)>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.1DeviceStatus2CFPORT3D5]]]. 618 + 619 +(% style="color:red" %)**Note: LoRaWAN Server needs to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature.** 620 + 621 + 622 +(% style="color:blue" %)** 2. Manually Set Time** 623 + 624 +Users need to set SYNCMOD=0 to manual time, otherwise, the user set time will be overwritten by the time set by the server. 625 + 626 + 627 +=== 2.6.3 Poll sensor value === 628 + 629 + 630 +Users can poll sensor values based on timestamps. Below is the downlink command. 631 + 632 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:470px" %) 633 +|=(% colspan="4" style="width: 154px;background-color:#4F81BD;color:white" %)**Downlink Command to poll Open/Close status (0x31)** 634 +|(% style="background-color:#f2f2f2; width:70px" %)**1byte**|(% style="background-color:#f2f2f2; width:140px" %)**4bytes**|(% style="background-color:#f2f2f2; width:140px" %)((( 635 +((( 636 +**4bytes** 637 +))) 638 + 639 + 640 + 641 +)))|(% style="background-color:#f2f2f2; width:150px" %)**1byte** 642 +|(% style="background-color:#f2f2f2; width:70px" %)31|(% style="background-color:#f2f2f2; width:140px" %)Timestamp start|(% style="background-color:#f2f2f2; width:140px" %)Timestamp end|(% style="background-color:#f2f2f2; width:150px" %)Uplink Interval 643 + 644 +Timestamp start and Timestamp end-use Unix TimeStamp format as mentioned above. Devices will reply with all data logs during this period, using the uplink interval. 645 + 646 +For example, downlink command[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/image-20220518162852-1.png?rev=1.1||alt="image-20220518162852-1.png"]] 647 + 648 +Is to check 2021/11/12 12:00:00 to 2021/11/12 15:00:00's data 649 + 650 +Uplink Internal =5s,means CPL01 will send one packet every 5s. range 5~~255s. 651 + 652 + 653 +=== 2.6.4 Decoder in TTN V3 === 654 + 655 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652862574387-195.png?width=722&height=359&rev=1.1||alt="1652862574387-195.png" height="359" width="722"]] 656 + 657 +Please check the decoder from this link: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>url:https://github.com/dragino/dragino-end-node-decoder]] 658 + 659 + 660 +== 2.7 Frequency Plans == 661 + 662 + 574 574 The PS-LB/LS uses OTAA mode and below frequency plans by default. Each frequency band use different firmware, user update the firmware to the corresponding band for their country. 575 575 576 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 665 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/a>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]] 577 577 578 578 579 -== 2. 7Firmware ChangeLog==668 +== 2.8 Report on Change Feature (Since firmware V1.1.2) == 580 580 670 +=== 2.8.1 Uplink payload(Enable ROC) === 581 581 672 + 673 +Used to Monitor the IDC and VDC increments, and send ROC uplink when the IDC or VDC changes exceed. 674 + 675 +With ROC enabled, the payload is as follows: 676 + 677 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 678 +|(% style="background-color:#4f81bd; color:white; width:97px" %)((( 679 +**Size(bytes)** 680 +)))|(% style="background-color:#4f81bd; color:white; width:48px" %)**2**|(% style="background-color:#4f81bd; color:white; width:71px" %)**2**|(% style="background-color:#4f81bd; color:white; width:98px" %)**2**|(% style="background-color:#4f81bd; color:white; width:73px" %)**2**|(% style="background-color:#4f81bd; color:white; width:122px" %)**1** 681 +|(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)((( 682 +[[IN1 &IN2 Interrupt flag>>||anchor="H2.3.7IN126IN226INTpin"]] & ROC_flag 683 +))) 684 + 685 +(% style="color:blue" %)**IN1 &IN2 , Interrupt flag , ROC_flag:** 686 + 687 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:515px" %) 688 +|(% style="background-color:#4f81bd; color:white; width:50px" %)**Size(bit)**|(% style="background-color:#4f81bd; color:white; width:60px" %)**bit7**|(% style="background-color:#4f81bd; color:white; width:62px" %)**bit6**|(% style="background-color:#4f81bd; color:white; width:62px" %)**bit5**|(% style="background-color:#4f81bd; color:white; width:65px" %)**bit4**|(% style="background-color:#4f81bd; color:white; width:56px" %)**bit3**|(% style="background-color:#4f81bd; color:white; width:55px" %)**bit2**|(% style="background-color:#4f81bd; color:white; width:55px" %)**bit1**|(% style="background-color:#4f81bd; color:white; width:50px" %)**bit0** 689 +|(% style="width:75px" %)Value|(% style="width:89px" %)IDC_Roc_flagL|(% style="width:46.5834px" %)IDC_Roc_flagH|(% style="width:1px" %)VDC_Roc_flagL|(% style="width:89px" %)VDC_Roc_flagH|(% style="width:89px" %)IN1_pin_level|(% style="width:103px" %)IN2_pin_level|(% style="width:103px" %)Exti_pin_level|(% style="width:103px" %)Exti_status 690 + 691 +* (% style="color:#037691" %)**IDC_Roc_flagL** 692 + 693 +80 (H): (0x80&0x80)=80(H)=**1**000 0000(B) bit7=1, "TRUE", This uplink is triggered when the decrease in the IDC compared to the last ROC refresh exceeds the set threshold. 694 + 695 +60 (H): (0x60&0x80)=0 bit7=0, "FALSE", This uplink is not triggered when the decrease in the IDC compared to the last ROC refresh exceeds the set threshold. 696 + 697 + 698 +* (% style="color:#037691" %)**IDC_Roc_flagH** 699 + 700 +60 (H): (0x60&0x40)=60(H)=0**1**000 0000(B) bit6=1, "TRUE", This uplink is triggered when the increase in the value of the IDC compared to the last ROC refresh exceeds the set threshold. 701 + 702 +80 (H): (0x80&0x40)=0 bit6=0, "FALSE", This uplink is not triggered when the increase in the value of the IDC compared to the last ROC refresh exceeds the set threshold. 703 + 704 + 705 +* (% style="color:#037691" %)**VDC_Roc_flagL** 706 + 707 +20 (H): (0x20&0x20)=20(H)=00**1**0 0000(B) bit5=1, "TRUE", This uplink is triggered when the decrease in the VDC compared to the last ROC refresh exceeds the set threshold. 708 + 709 +90 (H): (0x90&0x20)=0 bit5=0, "FALSE", This uplink is not triggered when the decrease in the VDC compared to the last ROC refresh exceeds the set threshold. 710 + 711 + 712 +* (% style="color:#037691" %)**VDC_Roc_flagH** 713 + 714 +90 (H): (0x90&0x10)=10(H)=000**1** 0000(B) bit4=1, "TRUE", This uplink is triggered when the increase in the value of the VDC compared to the last ROC refresh exceeds the set threshold. 715 + 716 +20 (H): (0x20&0x10)=0 bit4=0, "FALSE", This uplink is not triggered when the increase in the value of the VDC compared to the last ROC refresh exceeds the set threshold. 717 + 718 + 719 +* (% style="color:#037691" %)**IN1_pin_level & IN2_pin_level** 720 + 721 +IN1 and IN2 are used as digital input pins. 722 + 723 +80 (H): (0x80&0x08)=0 IN1 pin is low level. 724 + 725 +80 (H): (0x09&0x04)=0 IN2 pin is low level. 726 + 727 + 728 +* (% style="color:#037691" %)**Exti_pin_level &Exti_status** 729 + 730 +This data field shows whether the packet is generated by an interrupt pin. 731 + 732 +Note: The Internet pin of the old motherboard is a separate pin in the screw terminal, and the interrupt pin of the new motherboard(SIB V1.3) is the **GPIO_EXTI** pin. 733 + 734 +**Exti_pin_level:** 80 (H): (0x80&0x02)=0 "low", The level of the interrupt pin. 735 + 736 +**Exti_status: **80 (H): (0x80&0x01)=0 "False", Normal uplink packet. 737 + 738 + 739 +=== 2.8.2 Set the Report on Change === 740 + 741 + 742 +Feature: Set the detection interval and threshold to monitor whether the IDC/VDC variable exceeds the threshold. If the threshold is exceeded, an ROC uplink is sent. 743 +(% style="color:blue" %)**AT Command: AT+ROC** 744 + 745 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 746 +|=(% style="width: 143px; background-color: rgb(79, 129, 189); color: white;" %)**Command Example**|=(% style="width: 197px; background-color: rgb(79, 129, 189); color: white;" %)**Parameters**|=(% style="width: 170px; background-color: rgb(79, 129, 189); color: white;" %)**Response/Explanation** 747 +|(% style="width:143px" %)AT+ROC=?|(% style="width:197px" %)Show current ROC setting|(% style="width:168px" %)((( 748 +0,0,0,0(default) 749 + 750 +OK 751 +))) 752 +|(% colspan="1" rowspan="4" style="width:143px" %)((( 753 + 754 + 755 + 756 + 757 +AT+ROC=a,b,c,d 758 +)))|(% style="width:197px" %)**a**: Enable or disable the ROC|(% style="width:168px" %)((( 759 +0: off 760 + 761 +1: on 762 +))) 763 +|(% style="width:197px" %)**b**: Set the detection interval|(% style="width:168px" %)Unit: second 764 +|(% style="width:197px" %)**c**: Setting the IDC change threshold|(% style="width:168px" %)Unit: uA 765 +|(% style="width:197px" %)**d**: Setting the VDC change threshold|(% style="width:168px" %)Unit: mV 766 + 767 +**Example:** 768 + 769 +* AT+ROC=1,60,3000, 500 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA) or VDC (>500mV), sends an ROC uplink. 770 +* AT+ROC=1,60,3000,0 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink. 0 Means doesn't monitor Voltage. 771 + 772 +(% style="color:blue" %)**Downlink Command: 0x09 aa bb cc dd** 773 + 774 +Format: Function code (0x09) followed by 4 bytes. 775 + 776 +(% style="color:blue" %)**aa: **(%%)Enable/Disable the ROC. 777 + 778 +(% style="color:blue" %)**bb: **(%%)Set the detection interval. (second) 779 + 780 +(% style="color:blue" %)**cc: **(%%)Setting the IDC change threshold. (uA) 781 + 782 +(% style="color:blue" %)**dd: **(%%)Setting the VDC change threshold. (mV) 783 + 784 +**Example:** 785 + 786 +* Downlink Payload: **09 01 00 3C 0B B8 01 F4 ** ~/~/ Equal to AT+ROC=1,60,3000, 500 787 +* Downlink Payload: **09 01 00 3C 0B B8 00 00 ** ~/~/ AT+ROC=1,60,3000,0 788 + 789 +(% style="color:blue" %)**Screenshot of parsing example in TTN:** 790 + 791 +* AT+ROC=1,60,3000, 500. 792 + 793 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/PS-LB-NA--LoRaWAN_Analog_Sensor_User_Manual/WebHome/image-20241019170902-1.png?width=1454&height=450&rev=1.1||alt="image-20241019170902-1.png"]] 794 + 795 + 796 +== 2.9 Firmware Change Log == 797 + 798 + 582 582 **Firmware download link:** 583 583 584 584 [[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]] ... ... @@ -759,6 +759,12 @@ 759 759 760 760 (A->01,B->02,C->03,D->04,E->05,F->06,G->07,H->08,I->09,J->0A,K->0B,L->0C) 761 761 979 +When aa=02, it is the Differential Pressure Sensor , which converts the current into a pressure value; 980 + 981 +bb represents which type of pressure sensor it is. 982 + 983 +(0~~100Pa->01,0~~200Pa->02,0~~300Pa->03,0~~1KPa->04,0~~2KPa->05,0~~3KPa->06,0~~4KPa->07,0~~5KPa->08,0~~10KPa->09,-100~~ 100Pa->0A,-200~~ 200Pa->0B,-1~~ 1KPa->0C) 984 + 762 762 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 763 763 |(% style="background-color:#4f81bd; color:white; width:154px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:269px" %)**Function**|(% style="background-color:#4f81bd; color:white" %)**Response** 764 764 |(% style="background-color:#f2f2f2; width:154px" %)AT+PROBE=?|(% style="background-color:#f2f2f2; width:269px" %)Get or Set the probe model.|(% style="background-color:#f2f2f2" %)0 ... ... @@ -781,7 +781,7 @@ 781 781 === 3.3.5 Multiple collections are one uplink (Since firmware V1.1) === 782 782 783 783 784 -Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time. 1007 +Added AT+STDC command to collect the voltage of VDC_INPUT/IDC_INPUT multiple times and upload it at one time. 785 785 786 786 (% style="color:blue" %)**AT Command: AT** **+STDC** 787 787 ... ... @@ -789,7 +789,8 @@ 789 789 790 790 (% style="color:#037691" %)**aa:**(%%) 791 791 **0:** means disable this function and use TDC to send packets. 792 -**1:** means enable this function, use the method of multiple acquisitions to send packets. 1015 +**1:** means that the function is enabled to send packets by collecting VDC data for multiple times. 1016 +**2:** means that the function is enabled to send packets by collecting IDC data for multiple times. 793 793 (% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535 794 794 (% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120 795 795 ... ... @@ -814,7 +814,7 @@ 814 814 815 815 (% style="color:blue" %)**Downlink Command: 0xAE** 816 816 817 -Format: Command Code (0x 08) followed by5bytes.1041 +Format: Command Code (0xAE) followed by 4 bytes. 818 818 819 819 * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 820 820 ... ... @@ -898,8 +898,9 @@ 898 898 = 8. Order Info = 899 899 900 900 901 - [[image:image-20240109172423-7.png]](% style="display:none" %)1125 +(% style="display:none" %) 902 902 1127 +[[image:image-20241021093209-1.png]] 903 903 904 904 = 9. Packing Info = 905 905 ... ... @@ -921,5 +921,3 @@ 921 921 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 922 922 923 923 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]]. 924 - 925 -
- image-20240817150702-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +38.4 KB - Content
- image-20241021093209-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.1 KB - Content