... ... @@ -146,20 +146,18 @@
146 146  * Operating temperature: 0℃~~50℃
147 147  * Material: 316 stainless steels
148 148  
149 -
150 150  === 1.4.3 Wireless Differential Air Pressure Sensor ===
151 151  
152 152  [[image:image-20240511174954-1.png]]
153 153  
154 -* Measuring Range: -100KPa~~0~~100KPa,Intermediate range is optional.
153 +* Measuring Range: -100KPa~~0~~100KPa(Optional measuring range).
155 155  * Accuracy: 0.5% F.S, resolution is 0.05%.
156 156  * Overload: 300% F.S
157 157  * Zero temperature drift: ±0.03%F.S/°C
158 -* Operating temperature: -40℃~~85℃
157 +* Operating temperature: -20℃~~60℃
158 +* Storage temperature:  -20℃~~60℃
159 159  * Compensation temperature: 0~~50°C
160 160  
161 -
162 -
163 163  == 1.5 Application and Installation ==
164 164  
165 165  === 1.5.1 Thread Installation Type ===
... ... @@ -190,7 +190,7 @@
190 190  [[image:1675071725288-579.png]]
191 191  
192 192  
193 -The Immersion Type pressure sensor is shipped with the probe and device separately. When user got the device, below is the wiring to for connect the probe to the device.
191 +Below is the wiring to for connect the probe to the device.
194 194  
195 195  The Immersion Type Sensor has different variant which defined by Ixx. For example, this means two points:
196 196  
... ... @@ -203,6 +203,31 @@
203 203  [[image:1675071776102-240.png]]
204 204  
205 205  
204 +
205 +=== 1.5.3 Wireless Differential Air Pressure Sensor ===
206 +
207 +
208 +(% style="color:blue" %)**Application:**
209 +
210 +Indoor Air Control & Filter clogging Detect.
211 +
212 +[[image:image-20240513100129-6.png]]
213 +
214 +[[image:image-20240513100135-7.png]]
215 +
216 +
217 +Below is the wiring to for connect the probe to the device.
218 +
219 +[[image:image-20240513093957-1.png]]
220 +
221 +
222 +Size of wind pressure transmitter:
223 +
224 +[[image:image-20240513094047-2.png]]
225 +
226 +Note: The above dimensions are measured by hand, and the numerical error of the shell is within ±0.2mm.
227 +
228 +
206 206  == 1.6 Sleep mode and working mode ==
207 207  
208 208  
... ... @@ -568,15 +568,88 @@
568 568  [[image:1675145081239-376.png]]
569 569  
570 570  
571 -== 2.6 Frequency Plans ==
594 +== 2.6 Datalog Feature (Since V1.1) ==
572 572  
596 +When a user wants to retrieve sensor value, he can send a poll command from the IoT platform to ask the sensor to send value in the required time slot.
573 573  
598 +
599 +
600 +=== 2.6.1 Unix TimeStamp ===
601 +
602 +CPL01 uses Unix TimeStamp format based on
603 +
604 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652861618065-927.png?width=705&height=109&rev=1.1||alt="1652861618065-927.png" height="109" width="705"]]
605 +
606 +Users can get this time from the link:  [[https:~~/~~/www.epochconverter.com/>>url:https://www.epochconverter.com/]] :
607 +
608 +Below is the converter example:
609 +
610 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652861637105-371.png?width=732&height=428&rev=1.1||alt="1652861637105-371.png"]]
611 +
612 +
613 +=== 2.6.2 Set Device Time ===
614 +
615 +There are two ways to set the device's time:
616 +
617 +
618 +(% style="color:blue" %)**1. Through LoRaWAN MAC Command (Default settings)**
619 +
620 +Users need to set SYNCMOD=1 to enable sync time via the MAC command.
621 +
622 +Once CPL01 Joined the LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to CPL01. If CPL01 fails to get the time from the server, CPL01 will use the internal time and wait for the next time request ~[[[via Device Status (FPORT=5)>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.1DeviceStatus2CFPORT3D5]]].
623 +
624 +
625 +(% style="color:red" %)**Note: LoRaWAN Server needs to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature.**
626 +
627 +
628 +(% style="color:blue" %)** 2. Manually Set Time**
629 +
630 +Users need to set SYNCMOD=0 to manual time, otherwise, the user set time will be overwritten by the time set by the server.
631 +
632 +
633 +=== 2.6.3 Poll sensor value ===
634 +
635 +Users can poll sensor values based on timestamps. Below is the downlink command.
636 +
637 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:470px" %)
638 +|=(% colspan="4" style="width: 154px;background-color:#4F81BD;color:white" %)**Downlink Command to poll Open/Close status (0x31)**
639 +|(% style="background-color:#f2f2f2; width:70px" %)**1byte**|(% style="background-color:#f2f2f2; width:140px" %)**4bytes**|(% style="background-color:#f2f2f2; width:140px" %)(((
640 +(((
641 +**4bytes**
642 +)))
643 +
644 +(((
645 +
646 +)))
647 +)))|(% style="background-color:#f2f2f2; width:150px" %)**1byte**
648 +|(% style="background-color:#f2f2f2; width:70px" %)31|(% style="background-color:#f2f2f2; width:140px" %)Timestamp start|(% style="background-color:#f2f2f2; width:140px" %)Timestamp end|(% style="background-color:#f2f2f2; width:150px" %)Uplink Interval
649 +
650 +Timestamp start and Timestamp end-use Unix TimeStamp format as mentioned above. Devices will reply with all data logs during this period, using the uplink interval.
651 +
652 +For example, downlink command[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/image-20220518162852-1.png?rev=1.1||alt="image-20220518162852-1.png"]]
653 +
654 +Is to check 2021/11/12 12:00:00 to 2021/11/12 15:00:00's data
655 +
656 +Uplink Internal =5s,means CPL01 will send one packet every 5s. range 5~~255s.
657 +
658 +
659 +=== 2.6.4 Decoder in TTN V3 ===
660 +
661 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652862574387-195.png?width=722&height=359&rev=1.1||alt="1652862574387-195.png" height="359" width="722"]]
662 +
663 +Please check the decoder from this link: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>url:https://github.com/dragino/dragino-end-node-decoder]]
664 +
665 +
666 +
667 +== 2.7 Frequency Plans ==
668 +
669 +
574 574  The PS-LB/LS uses OTAA mode and below frequency plans by default. Each frequency band use different firmware, user update the firmware to the corresponding band for their country.
575 575  
576 576  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
577 577  
578 578  
579 -== 2.7 ​Firmware Change Log ==
675 +== 2.8 ​Firmware Change Log ==
580 580  
581 581  
582 582  **Firmware download link:**
... ... @@ -781,7 +781,7 @@
781 781  === 3.3.5 Multiple collections are one uplink (Since firmware V1.1) ===
782 782  
783 783  
784 -Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time.
880 +Added AT+STDC command to collect the voltage of VDC_INPUT/IDC_INPUT multiple times and upload it at one time.
785 785  
786 786  (% style="color:blue" %)**AT Command: AT** **+STDC**
787 787  
... ... @@ -789,7 +789,8 @@
789 789  
790 790  (% style="color:#037691" %)**aa:**(%%)
791 791  **0:** means disable this function and use TDC to send packets.
792 -**1:** means enable this function, use the method of multiple acquisitions to send packets.
888 +**1:** means that the function is enabled to send packets by collecting VDC data for multiple times.
889 +**2:** means that the function is enabled to send packets by collecting IDC data for multiple times.
793 793  (% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535
794 794  (% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120
795 795  
... ... @@ -814,7 +814,7 @@
814 814  
815 815  (% style="color:blue" %)**Downlink Command: 0xAE**
816 816  
817 -Format: Command Code (0x08) followed by 5 bytes.
914 +Format: Command Code (0xAE) followed by 4 bytes.
818 818  
819 819  * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->**  AT+STDC=1,600,18