... ... @@ -1,1 +1,1 @@
1 -XWiki.ting
1 +XWiki.Xiaoling
Content
... ... @@ -41,7 +41,7 @@
41 41  )))
42 42  
43 43  (((
44 -PS-LB/LS is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery **(%%)or (% style="color:blue" %)**solar powered + li-on battery **(%%), it is designed for long term use up to 5 years.
44 +PS-LB/LS is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery **(%%)or (% style="color:blue" %)**solar powered + Li-ion battery **(%%), it is designed for long term use up to 5 years.
45 45  )))
46 46  
47 47  (((
... ... @@ -67,7 +67,7 @@
67 67  * Downlink to change configure
68 68  * Controllable 3.3v,5v and 12v output to power external sensor
69 69  * 8500mAh Li/SOCl2 Battery (PS-LB)
70 -* Solar panel + 3000mAh Li-on battery (PS-LS)
70 +* Solar panel + 3000mAh Li-ion battery (PS-LS)
71 71  
72 72  == 1.3 Specification ==
73 73  
... ... @@ -136,16 +136,28 @@
136 136  === 1.4.2 Immersion Type ===
137 137  
138 138  
139 -[[image:image-20240109160445-5.png||height="284" width="214"]]
139 +[[image:image-20240109160445-5.png||height="221" width="166"]]
140 140  
141 141  * Immersion Type, Probe IP Level: IP68
142 142  * Measuring Range: Measure range can be customized, up to 100m.
143 143  * Accuracy: 0.2% F.S
144 144  * Long-Term Stability: ±0.2% F.S / Year
145 -* Storage temperature: -30~~80
146 -* Operating temperature: 0~~50
145 +* Storage temperature: -30°C~~80°C
146 +* Operating temperature: 0°C~~50°C
147 147  * Material: 316 stainless steels
148 148  
149 +=== 1.4.3 Wireless Differential Air Pressure Sensor ===
150 +
151 +[[image:image-20240511174954-1.png]]
152 +
153 +* Measuring Range: -100KPa~~0~~100KPa(Optional measuring range).
154 +* Accuracy: 0.5% F.S, resolution is 0.05%.
155 +* Overload: 300% F.S
156 +* Zero temperature drift: ±0.03%F.S/°C
157 +* Operating temperature: -20°C~~60°C
158 +* Storage temperature:  -20°C~~60°C
159 +* Compensation temperature: 0~~50°C
160 +
149 149  == 1.5 Application and Installation ==
150 150  
151 151  === 1.5.1 Thread Installation Type ===
... ... @@ -176,7 +176,7 @@
176 176  [[image:1675071725288-579.png]]
177 177  
178 178  
179 -The Immersion Type pressure sensor is shipped with the probe and device separately. When user got the device, below is the wiring to for connect the probe to the device.
191 +Below is the wiring to for connect the probe to the device.
180 180  
181 181  The Immersion Type Sensor has different variant which defined by Ixx. For example, this means two points:
182 182  
... ... @@ -189,6 +189,31 @@
189 189  [[image:1675071776102-240.png]]
190 190  
191 191  
204 +
205 +=== 1.5.3 Wireless Differential Air Pressure Sensor ===
206 +
207 +
208 +(% style="color:blue" %)**Application:**
209 +
210 +Indoor Air Control & Filter clogging Detect.
211 +
212 +[[image:image-20240513100129-6.png]]
213 +
214 +[[image:image-20240513100135-7.png]]
215 +
216 +
217 +Below is the wiring to for connect the probe to the device.
218 +
219 +[[image:image-20240513093957-1.png]]
220 +
221 +
222 +Size of wind pressure transmitter:
223 +
224 +[[image:image-20240513094047-2.png]]
225 +
226 +Note: The above dimensions are measured by hand, and the numerical error of the shell is within ±0.2mm.
227 +
228 +
192 192  == 1.6 Sleep mode and working mode ==
193 193  
194 194  
... ... @@ -238,7 +238,7 @@
238 238  
239 239  == 1.10 Mechanical ==
240 240  
241 -=== 1.10.1 for LB version(% style="display:none" %) (%%) ===
278 +=== 1.10.1 for LB version ===
242 242  
243 243  
244 244  [[image:image-20240109160800-6.png]]
... ... @@ -554,17 +554,219 @@
554 554  [[image:1675145081239-376.png]]
555 555  
556 556  
557 -== 2.6 Frequency Plans ==
594 +== 2.6 Datalog Feature (Since V1.1) ==
558 558  
596 +When a user wants to retrieve sensor value, he can send a poll command from the IoT platform to ask the sensor to send value in the required time slot.
559 559  
598 +
599 +
600 +=== 2.6.1 Unix TimeStamp ===
601 +
602 +CPL01 uses Unix TimeStamp format based on
603 +
604 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652861618065-927.png?width=705&height=109&rev=1.1||alt="1652861618065-927.png" height="109" width="705"]]
605 +
606 +Users can get this time from the link:  [[https:~~/~~/www.epochconverter.com/>>url:https://www.epochconverter.com/]] :
607 +
608 +Below is the converter example:
609 +
610 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652861637105-371.png?width=732&height=428&rev=1.1||alt="1652861637105-371.png"]]
611 +
612 +
613 +=== 2.6.2 Set Device Time ===
614 +
615 +There are two ways to set the device's time:
616 +
617 +
618 +(% style="color:blue" %)**1. Through LoRaWAN MAC Command (Default settings)**
619 +
620 +Users need to set SYNCMOD=1 to enable sync time via the MAC command.
621 +
622 +Once CPL01 Joined the LoRaWAN network, it will send the MAC command (DeviceTimeReq) and the server will reply with (DeviceTimeAns) to send the current time to CPL01. If CPL01 fails to get the time from the server, CPL01 will use the internal time and wait for the next time request ~[[[via Device Status (FPORT=5)>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.1DeviceStatus2CFPORT3D5]]].
623 +
624 +
625 +(% style="color:red" %)**Note: LoRaWAN Server needs to support LoRaWAN v1.0.3(MAC v1.0.3) or higher to support this MAC command feature.**
626 +
627 +
628 +(% style="color:blue" %)** 2. Manually Set Time**
629 +
630 +Users need to set SYNCMOD=0 to manual time, otherwise, the user set time will be overwritten by the time set by the server.
631 +
632 +
633 +=== 2.6.3 Poll sensor value ===
634 +
635 +Users can poll sensor values based on timestamps. Below is the downlink command.
636 +
637 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:470px" %)
638 +|=(% colspan="4" style="width: 154px;background-color:#4F81BD;color:white" %)**Downlink Command to poll Open/Close status (0x31)**
639 +|(% style="background-color:#f2f2f2; width:70px" %)**1byte**|(% style="background-color:#f2f2f2; width:140px" %)**4bytes**|(% style="background-color:#f2f2f2; width:140px" %)(((
640 +(((
641 +**4bytes**
642 +)))
643 +
644 +
645 +)))|(% style="background-color:#f2f2f2; width:150px" %)**1byte**
646 +|(% style="background-color:#f2f2f2; width:70px" %)31|(% style="background-color:#f2f2f2; width:140px" %)Timestamp start|(% style="background-color:#f2f2f2; width:140px" %)Timestamp end|(% style="background-color:#f2f2f2; width:150px" %)Uplink Interval
647 +
648 +Timestamp start and Timestamp end-use Unix TimeStamp format as mentioned above. Devices will reply with all data logs during this period, using the uplink interval.
649 +
650 +For example, downlink command[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/image-20220518162852-1.png?rev=1.1||alt="image-20220518162852-1.png"]]
651 +
652 +Is to check 2021/11/12 12:00:00 to 2021/11/12 15:00:00's data
653 +
654 +Uplink Internal =5s,means CPL01 will send one packet every 5s. range 5~~255s.
655 +
656 +
657 +=== 2.6.4 Decoder in TTN V3 ===
658 +
659 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652862574387-195.png?width=722&height=359&rev=1.1||alt="1652862574387-195.png" height="359" width="722"]]
660 +
661 +Please check the decoder from this link: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>url:https://github.com/dragino/dragino-end-node-decoder]]
662 +
663 +
664 +
665 +== 2.7 Frequency Plans ==
666 +
667 +
560 560  The PS-LB/LS uses OTAA mode and below frequency plans by default. Each frequency band use different firmware, user update the firmware to the corresponding band for their country.
561 561  
562 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
670 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/a>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
563 563  
564 564  
565 -== 2.7 ​Firmware Change Log ==
673 +== 2.8 Report on Change Feature (Since firmware V1.1.2) ==
566 566  
567 567  
676 +=== 2.8.1 Uplink payload(Enable ROC) ===
677 +
678 +
679 +Used to Monitor the IDC and VDC increments, and send ROC uplink when the IDC or VDC changes exceed.
680 +
681 +With ROC enabled, the payload is as follows:
682 +
683 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
684 +|(% style="background-color:#4f81bd; color:white; width:97px" %)(((
685 +**Size(bytes)**
686 +)))|(% style="background-color:#4f81bd; color:white; width:48px" %)**2**|(% style="background-color:#4f81bd; color:white; width:71px" %)**2**|(% style="background-color:#4f81bd; color:white; width:98px" %)**2**|(% style="background-color:#4f81bd; color:white; width:73px" %)**2**|(% style="background-color:#4f81bd; color:white; width:122px" %)**1**
687 +|(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)(((
688 +[[IN1 &IN2 Interrupt  flag>>||anchor="H2.3.7IN126IN226INTpin"]]
689 +
690 +& **ROC_flag**
691 +)))
692 +
693 +(% style="color:blue" %)**IN1 &IN2 , Interrupt  flag , ROC_flag:**
694 +
695 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
696 +|(% style="background-color:#4f81bd; color:white; width:55px" %)**Size(bit)**|(% style="background-color:#4f81bd; color:white; width:65px" %)**bit7**|(% style="background-color:#4f81bd; color:white; width:46.5834px" %)**bit6**|(% style="background-color:#4f81bd; color:white; width:1px" %)**bit5**|(% style="background-color:#4f81bd; color:white; width:65px" %)**bit4**|(% style="background-color:#4f81bd; color:white; width:65px" %)**bit3**|(% style="background-color:#4f81bd; color:white; width:105px" %)**bit2**|(% style="background-color:#4f81bd; color:white; width:105px" %)**bit1**|(% style="background-color:#4f81bd; color:white; width:105px" %)**bit0**
697 +|(% style="width:75px" %)Value|(% style="width:89px" %)IDC_Roc_flagL|(% style="width:46.5834px" %)IDC_Roc_flagH|(% style="width:1px" %)VDC_Roc_flagL|(% style="width:89px" %)VDC_Roc_flagH|(% style="width:89px" %)IN1_pin_level|(% style="width:103px" %)IN2_pin_level|(% style="width:103px" %)Exti_pin_level|(% style="width:103px" %)Exti_status
698 +
699 +* (% style="color:#037691" %)**IDC_Roc_flagL**
700 +
701 +80 (H): (0x80&0x80)=80(H)=**1**000 0000(B)  bit7=1, "TRUE", This uplink is triggered when the decrease in the IDC compared to the last ROC refresh exceeds the set threshold.
702 +
703 +60 (H): (0x60&0x80)=0  bit7=0, "FALSE", This uplink is not triggered when the decrease in the IDC compared to the last ROC refresh exceeds the set threshold.
704 +
705 +
706 +* (% style="color:#037691" %)**IDC_Roc_flagH**
707 +
708 +60 (H): (0x60&0x40)=60(H)=0**1**000 0000(B)  bit6=1, "TRUE", This uplink is triggered when the increase in the value of the IDC compared to the last ROC refresh exceeds the set threshold.
709 +
710 +80 (H): (0x80&0x40)=0  bit6=0, "FALSE", This uplink is not triggered when the increase in the value of the IDC compared to the last ROC refresh exceeds the set threshold.
711 +
712 +
713 +* (% style="color:#037691" %)**VDC_Roc_flagL**
714 +
715 +20 (H): (0x20&0x20)=20(H)=00**1**0 0000(B)  bit5=1, "TRUE", This uplink is triggered when the decrease in the VDC compared to the last ROC refresh exceeds the set threshold.
716 +
717 +90 (H): (0x90&0x20)=0  bit5=0, "FALSE", This uplink is not triggered when the decrease in the VDC compared to the last ROC refresh exceeds the set threshold.
718 +
719 +
720 +* (% style="color:#037691" %)**VDC_Roc_flagH**
721 +
722 +90 (H): (0x90&0x10)=10(H)=000**1** 0000(B)  bit4=1, "TRUE", This uplink is triggered when the increase in the value of the VDC compared to the last ROC refresh exceeds the set threshold.
723 +
724 +20 (H): (0x20&0x10)=0  bit4=0, "FALSE", This uplink is not triggered when the increase in the value of the VDC compared to the last ROC refresh exceeds the set threshold.
725 +
726 +
727 +* (% style="color:#037691" %)**IN1_pin_level & IN2_pin_level**
728 +
729 +IN1 and IN2 are used as digital input pins.
730 +
731 +80 (H): (0x80&0x08)=0  IN1 pin is low level.
732 +
733 +80 (H): (0x09&0x04)=0    IN2 pin is low level.
734 +
735 +
736 +* (% style="color:#037691" %)**Exti_pin_level &Exti_status**
737 +
738 +This data field shows whether the packet is generated by an interrupt pin.
739 +
740 +Note: The Internet pin of the old motherboard is a separate pin in the screw terminal, and the interrupt pin of the new motherboard(SIB V1.3) is the **GPIO_EXTI** pin.
741 +
742 +**Exti_pin_level:**  80 (H): (0x80&0x02)=0  "low", The level of the interrupt pin.
743 +
744 +**Exti_status: **80 (H): (0x80&0x01)=0  "False", Normal uplink packet.
745 +
746 +
747 +=== 2.8.2 Set the Report on Change ===
748 +
749 +
750 +Feature: Set the detection interval and threshold to monitor whether the IDC/VDC variable exceeds the threshold. If the threshold is exceeded, an ROC uplink is sent.
751 +(% style="color:blue" %)**AT Command: AT+ROC**
752 +
753 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
754 +|=(% style="width: 143px; background-color: rgb(79, 129, 189); color: white;" %)**Command Example**|=(% style="width: 197px; background-color: rgb(79, 129, 189); color: white;" %)**Parameters**|=(% style="width: 168px; background-color: rgb(79, 129, 189); color: white;" %)**Response/Explanation**
755 +|(% style="width:143px" %)AT+ROC=?|(% style="width:197px" %)Show current ROC setting|(% style="width:168px" %)(((
756 +0,0,0,0(default)
757 +
758 +OK
759 +)))
760 +|(% colspan="1" rowspan="4" style="width:143px" %)(((
761 +
762 +
763 +
764 +
765 +AT+ROC=a,b,c,d
766 +)))|(% style="width:197px" %)**a**: Enable or disable the ROC|(% style="width:168px" %)(((
767 +0: off
768 +
769 +1: on
770 +)))
771 +|(% style="width:197px" %)**b**: Set the detection interval|(% style="width:168px" %)Unit: second
772 +|(% style="width:197px" %)**c**: Setting the IDC change threshold|(% style="width:168px" %)Unit: uA
773 +|(% style="width:197px" %)**d**: Setting the VDC change threshold|(% style="width:168px" %)Unit: mV
774 +
775 +**Example:**
776 +
777 +* AT+ROC=1,60,3000, 500  ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA) or VDC (>500mV), sends an ROC uplink.
778 +* AT+ROC=1,60,3000,0  ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink. 0 Means doesn't monitor Voltage.
779 +
780 +(% style="color:blue" %)**Downlink Command: 0x09 aa bb cc dd**
781 +
782 +Format: Function code (0x09) followed by 4 bytes.
783 +
784 +(% style="color:blue" %)**aa: **(%%)Enable/Disable the ROC.
785 +
786 +(% style="color:blue" %)**bb: **(%%)Set the detection interval. (second)
787 +
788 +(% style="color:blue" %)**cc: **(%%)Setting the IDC change threshold. (uA)
789 +
790 +(% style="color:blue" %)**dd: **(%%)Setting the VDC change threshold. (mV)
791 +
792 +**Example:**
793 +
794 +* Downlink Payload: **09 01 00 3C 0B B8 01 F4 ** ~/~/Equal to AT+ROC=1,60,3000, 500
795 +* Downlink Payload: **09 01 00 3C 0B B8 00 00 ** ~/~/AT+ROC=1,60,3000,0
796 +
797 +(% style="color:blue" %)**Screenshot of parsing example in TTN:**
798 +
799 +* AT+ROC=1,60,3000, 500.
800 +
801 +[[image:image-20241019170902-1.png||height="450" width="1454"]]
802 +
803 +
804 +== 2.9 ​Firmware Change Log ==
805 +
806 +
568 568  **Firmware download link:**
569 569  
570 570  [[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]]
... ... @@ -745,6 +745,12 @@
745 745  
746 746  (A->01,B->02,C->03,D->04,E->05,F->06,G->07,H->08,I->09,J->0A,K->0B,L->0C)
747 747  
987 +When aa=02, it is the Differential Pressure Sensor , which converts the current into a pressure value;
988 +
989 +bb represents which type of pressure sensor it is.
990 +
991 +(0~~100Pa->01,0~~200Pa->02,0~~300Pa->03,0~~1KPa->04,0~~2KPa->05,0~~3KPa->06,0~~4KPa->07,0~~5KPa->08,0~~10KPa->09,-100~~ 100Pa->0A,-200~~ 200Pa->0B,-1~~ 1KPa->0C)
992 +
748 748  (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
749 749  |(% style="background-color:#4f81bd; color:white; width:154px" %)**Command Example**|(% style="background-color:#4f81bd; color:white; width:269px" %)**Function**|(% style="background-color:#4f81bd; color:white" %)**Response**
750 750  |(% style="background-color:#f2f2f2; width:154px" %)AT+PROBE=?|(% style="background-color:#f2f2f2; width:269px" %)Get or Set the probe model.|(% style="background-color:#f2f2f2" %)0
... ... @@ -767,7 +767,7 @@
767 767  === 3.3.5 Multiple collections are one uplink (Since firmware V1.1) ===
768 768  
769 769  
770 -Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time.
1015 +Added AT+STDC command to collect the voltage of VDC_INPUT/IDC_INPUT multiple times and upload it at one time.
771 771  
772 772  (% style="color:blue" %)**AT Command: AT** **+STDC**
773 773  
... ... @@ -775,7 +775,8 @@
775 775  
776 776  (% style="color:#037691" %)**aa:**(%%)
777 777  **0:** means disable this function and use TDC to send packets.
778 -**1:** means enable this function, use the method of multiple acquisitions to send packets.
1023 +**1:** means that the function is enabled to send packets by collecting VDC data for multiple times.
1024 +**2:** means that the function is enabled to send packets by collecting IDC data for multiple times.
779 779  (% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535
780 780  (% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120
781 781  
... ... @@ -800,7 +800,7 @@
800 800  
801 801  (% style="color:blue" %)**Downlink Command: 0xAE**
802 802  
803 -Format: Command Code (0x08) followed by 5 bytes.
1049 +Format: Command Code (0xAE) followed by 4 bytes.
804 804  
805 805  * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->**  AT+STDC=1,600,18
806 806  
... ... @@ -886,6 +886,7 @@
886 886  
887 887  [[image:image-20240109172423-7.png]](% style="display:none" %)
888 888  
1135 +[[image:image-20240817150702-1.png]]
889 889  
890 890  = 9. ​Packing Info =
891 891  
... ... @@ -908,4 +908,3 @@
908 908  
909 909  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]].
910 910  
911 -
image-20240513093957-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +320.4 KB
Content
image-20240513094047-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +62.7 KB
Content
image-20240513094054-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +201.1 KB
Content
image-20240513095921-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +130.4 KB
Content
image-20240513095927-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +98.0 KB
Content
image-20240513100129-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +130.4 KB
Content
image-20240513100135-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +98.0 KB
Content
image-20240817150702-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +38.4 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved