... ... @@ -146,8 +146,6 @@
146 146  * Operating temperature: 0℃~~50℃
147 147  * Material: 316 stainless steels
148 148  
149 -
150 -
151 151  == 1.5 Application and Installation ==
152 152  
153 153  === 1.5.1 Thread Installation Type ===
... ... @@ -180,7 +180,11 @@
180 180  
181 181  The Immersion Type pressure sensor is shipped with the probe and device separately. When user got the device, below is the wiring to for connect the probe to the device.
182 182  
181 +The Immersion Type Sensor has different variant which defined by Ixx. For example, this means two points:
183 183  
183 +* Cable Length: 10 Meters
184 +* Water Detect Range: 0 ~~ 10 Meters.
185 +
184 184  [[image:1675071736646-450.png]]
185 185  
186 186  
... ... @@ -556,7 +556,7 @@
556 556  == 2.6 Frequency Plans ==
557 557  
558 558  
559 -The PS-LB/LS uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
561 +The PS-LB/LS uses OTAA mode and below frequency plans by default. Each frequency band use different firmware, user update the firmware to the corresponding band for their country.
560 560  
561 561  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
562 562  
... ... @@ -763,7 +763,7 @@
763 763  * Example 1: Downlink Payload: 080003  **~-~-->**  AT+PROBE=0003
764 764  * Example 2: Downlink Payload: 080101  **~-~-->**  AT+PROBE=0101
765 765  
766 -=== 3.3.5 Multiple collections are one uplinkSince firmware V1.1 ===
768 +=== 3.3.5 Multiple collections are one uplink (Since firmware V1.1) ===
767 767  
768 768  
769 769  Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time.
... ... @@ -838,6 +838,13 @@
838 838  When downloading the images, choose the required image file for download. ​
839 839  
840 840  
843 +== 6.4 How to measure the depth of other liquids other than water? ==
844 +
845 +
846 +Test the current values at the depth of different liquids and convert them to a linear scale.
847 +Replace its ratio with the ratio of water to current in the decoder.
848 +
849 +
841 841  = 7. Troubleshooting =
842 842  
843 843  == 7.1 Water Depth Always shows 0 in payload ==