Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/19 17:58
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -PS-LB --LoRaWAN Air Water Pressure Sensor User Manual 1 +PS-LB -- LoRaWAN Air Water Pressure Sensor User Manual - Content
-
... ... @@ -78,7 +78,7 @@ 78 78 79 79 (% style="color:#037691" %)**LoRa Spec:** 80 80 81 -* Frequency Range, Band 1 (HF): 862 ~~ 1020 Mhz ,Band 2 (LF): 410 ~~ 528 Mhz81 +* Frequency Range, Band 1 (HF): 862 ~~ 1020 Mhz 82 82 * Max +22 dBm constant RF output vs. 83 83 * RX sensitivity: down to -139 dBm. 84 84 * Excellent blocking immunity ... ... @@ -477,10 +477,10 @@ 477 477 478 478 479 479 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:508.222px" %) 480 -|(% style="background-color:#d9e2f3; width:94px ;color:#0070C0" %)(((480 +|(% style="background-color:#d9e2f3; width:94px" %)((( 481 481 **Size(bytes)** 482 -)))|(% style="background-color:#d9e2f3; width:43px ;color:#0070C0" %)**2**|(% style="background-color:#d9e2f3; width:367px;color:#0070C0" %)**n**483 -|(% style="width:94px" %)Value|(% style="width:43px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:367px" %)((( 482 +)))|(% style="background-color:#d9e2f3; width:43px" %)**2**|(% style="background-color:#d9e2f3; width:367px" %)**n** 483 +|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:367px" %)((( 484 484 Voltage value, each 2 bytes is a set of voltage values. 485 485 ))) 486 486 ... ... @@ -581,6 +581,8 @@ 581 581 * AT Command via UART Connection : See [[FAQ>>||anchor="H6.FAQ"]]. 582 582 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 583 583 584 + 585 + 584 584 == 3.2 General Commands == 585 585 586 586 ... ... @@ -628,6 +628,8 @@ 628 628 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 629 629 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 630 630 633 + 634 + 631 631 === 3.3.2 Set Interrupt Mode === 632 632 633 633 ... ... @@ -659,6 +659,8 @@ 659 659 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 660 660 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 661 661 666 + 667 + 662 662 === 3.3.3 Set the output time === 663 663 664 664 ... ... @@ -728,6 +728,8 @@ 728 728 * Example 5: Downlink Payload: 070301F4 **~-~-->** AT+12VT=500 729 729 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 730 730 737 + 738 + 731 731 === 3.3.4 Set the Probe Model === 732 732 733 733 ... ... @@ -765,6 +765,8 @@ 765 765 * Example 1: Downlink Payload: 080003 **~-~-->** AT+PROBE=0003 766 766 * Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 767 767 776 + 777 + 768 768 === 3.3.5 Multiple collections are one uplink(Since firmware V1.1) === 769 769 770 770 ... ... @@ -805,6 +805,8 @@ 805 805 806 806 * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 807 807 818 + 819 + 808 808 = 4. Battery & Power Consumption = 809 809 810 810 ... ... @@ -872,6 +872,8 @@ 872 872 * Package Size / pcs : cm 873 873 * Weight / pcs : g 874 874 887 + 888 + 875 875 = 10. Support = 876 876 877 877