Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/19 17:58
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -PS-LB --LoRaWAN Air Water Pressure Sensor User Manual 1 +PS-LB -- LoRaWAN Air Water Pressure Sensor User Manual - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -60,7 +60,6 @@ 60 60 * 8500mAh Battery for long term use 61 61 * Controllable 3.3v,5v and 12v output to power external sensor 62 62 63 -(% style="display:none" %) (%%) 64 64 65 65 == 1.3 Specification == 66 66 ... ... @@ -78,7 +78,7 @@ 78 78 79 79 (% style="color:#037691" %)**LoRa Spec:** 80 80 81 -* Frequency Range, Band 1 (HF): 862 ~~ 1020 Mhz ,Band 2 (LF): 410 ~~ 528 Mhz80 +* Frequency Range, Band 1 (HF): 862 ~~ 1020 Mhz 82 82 * Max +22 dBm constant RF output vs. 83 83 * RX sensitivity: down to -139 dBm. 84 84 * Excellent blocking immunity ... ... @@ -108,6 +108,7 @@ 108 108 * Sleep Mode: 5uA @ 3.3v 109 109 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 110 110 110 + 111 111 == 1.4 Probe Types == 112 112 113 113 === 1.4.1 Thread Installation Type === ... ... @@ -126,6 +126,7 @@ 126 126 * Operating temperature: -20℃~~60℃ 127 127 * Connector Type: Various Types, see order info 128 128 129 + 129 129 === 1.4.2 Immersion Type === 130 130 131 131 ... ... @@ -139,6 +139,7 @@ 139 139 * Operating temperature: 0℃~~50℃ 140 140 * Material: 316 stainless steels 141 141 143 + 142 142 == 1.5 Probe Dimension == 143 143 144 144 ... ... @@ -209,6 +209,7 @@ 209 209 ))) 210 210 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode. 211 211 214 + 212 212 == 1.9 Pin Mapping == 213 213 214 214 ... ... @@ -573,6 +573,7 @@ 573 573 * AT Command via UART Connection : See [[FAQ>>||anchor="H6.FAQ"]]. 574 574 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 575 575 579 + 576 576 == 3.2 General Commands == 577 577 578 578 ... ... @@ -620,6 +620,7 @@ 620 620 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 621 621 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 622 622 627 + 623 623 === 3.3.2 Set Interrupt Mode === 624 624 625 625 ... ... @@ -651,6 +651,7 @@ 651 651 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 652 652 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 653 653 659 + 654 654 === 3.3.3 Set the output time === 655 655 656 656 ... ... @@ -720,6 +720,7 @@ 720 720 * Example 5: Downlink Payload: 070301F4 **~-~-->** AT+12VT=500 721 721 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 722 722 729 + 723 723 === 3.3.4 Set the Probe Model === 724 724 725 725 ... ... @@ -757,6 +757,7 @@ 757 757 * Example 1: Downlink Payload: 080003 **~-~-->** AT+PROBE=0003 758 758 * Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 759 759 767 + 760 760 === 3.3.5 Multiple collections are one uplink(Since firmware V1.1) === 761 761 762 762 ... ... @@ -797,6 +797,7 @@ 797 797 798 798 * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 799 799 808 + 800 800 = 4. Battery & Power Consumption = 801 801 802 802 ... ... @@ -840,16 +840,11 @@ 840 840 841 841 = 8. Troubleshooting = 842 842 843 -== 8.1 Water Depth Always shows 0 in payload == 844 - 845 - 846 -If your device's IDC_intput_mA is normal, but your reading always shows 0, please refer to the following points: 847 - 852 +Unable to display water depth in payload 848 848 ~1. Please set it to mod1 849 849 2. Please set the command [[AT+PROBE>>http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/PS-LB%20--%20LoRaWAN%20Pressure%20Sensor/#H3.3.4SettheProbeModel]] according to the model of your sensor 850 850 3. Check the connection status of the sensor 851 851 852 - 853 853 = 9. Packing Info = 854 854 855 855 ... ... @@ -864,6 +864,7 @@ 864 864 * Package Size / pcs : cm 865 865 * Weight / pcs : g 866 866 871 + 867 867 = 10. Support = 868 868 869 869