Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/27 10:31
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -LoRaWAN A nalogSensor User Manual1 +PS-LB -- LoRaWAN Air Water Pressure Sensor User Manual - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Lu1 +XWiki.Xiaoling - Content
-
... ... @@ -60,6 +60,8 @@ 60 60 * 8500mAh Battery for long term use 61 61 * Controllable 3.3v,5v and 12v output to power external sensor 62 62 63 + 64 + 63 63 == 1.3 Specification == 64 64 65 65 ... ... @@ -76,7 +76,7 @@ 76 76 77 77 (% style="color:#037691" %)**LoRa Spec:** 78 78 79 -* Frequency Range, Band 1 (HF): 862 ~~ 1020 Mhz ,Band 2 (LF): 410 ~~ 528 Mhz81 +* Frequency Range, Band 1 (HF): 862 ~~ 1020 Mhz 80 80 * Max +22 dBm constant RF output vs. 81 81 * RX sensitivity: down to -139 dBm. 82 82 * Excellent blocking immunity ... ... @@ -106,6 +106,8 @@ 106 106 * Sleep Mode: 5uA @ 3.3v 107 107 * LoRa Transmit Mode: 125mA @ 20dBm, 82mA @ 14dBm 108 108 111 + 112 + 109 109 == 1.4 Probe Types == 110 110 111 111 === 1.4.1 Thread Installation Type === ... ... @@ -124,6 +124,8 @@ 124 124 * Operating temperature: -20℃~~60℃ 125 125 * Connector Type: Various Types, see order info 126 126 131 + 132 + 127 127 === 1.4.2 Immersion Type === 128 128 129 129 ... ... @@ -137,6 +137,8 @@ 137 137 * Operating temperature: 0℃~~50℃ 138 138 * Material: 316 stainless steels 139 139 146 + 147 + 140 140 == 1.5 Probe Dimension == 141 141 142 142 ... ... @@ -207,6 +207,8 @@ 207 207 ))) 208 208 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode. 209 209 218 + 219 + 210 210 == 1.9 Pin Mapping == 211 211 212 212 ... ... @@ -571,6 +571,8 @@ 571 571 * AT Command via UART Connection : See [[FAQ>>||anchor="H6.FAQ"]]. 572 572 * LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 573 573 584 + 585 + 574 574 == 3.2 General Commands == 575 575 576 576 ... ... @@ -618,6 +618,8 @@ 618 618 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 619 619 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 620 620 633 + 634 + 621 621 === 3.3.2 Set Interrupt Mode === 622 622 623 623 ... ... @@ -649,6 +649,8 @@ 649 649 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 650 650 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 651 651 666 + 667 + 652 652 === 3.3.3 Set the output time === 653 653 654 654 ... ... @@ -718,6 +718,8 @@ 718 718 * Example 5: Downlink Payload: 070301F4 **~-~-->** AT+12VT=500 719 719 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 720 720 737 + 738 + 721 721 === 3.3.4 Set the Probe Model === 722 722 723 723 ... ... @@ -755,6 +755,8 @@ 755 755 * Example 1: Downlink Payload: 080003 **~-~-->** AT+PROBE=0003 756 756 * Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 757 757 776 + 777 + 758 758 === 3.3.5 Multiple collections are one uplink(Since firmware V1.1) === 759 759 760 760 ... ... @@ -795,6 +795,8 @@ 795 795 796 796 * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 797 797 818 + 819 + 798 798 = 4. Battery & Power Consumption = 799 799 800 800 ... ... @@ -836,21 +836,9 @@ 836 836 [[image:image-20230131153105-4.png]] 837 837 838 838 839 -= 8. Troubleshooting =861 += 8. Packing Info = 840 840 841 -== 8.1 Water Depth Always shows 0 in payload == 842 842 843 - 844 -If your device's IDC_intput_mA is normal, but your reading always shows 0, please refer to the following points: 845 - 846 -~1. Please set it to mod1 847 -2. Please set the command [[AT+PROBE>>http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/PS-LB%20--%20LoRaWAN%20Pressure%20Sensor/#H3.3.4SettheProbeModel]] according to the model of your sensor 848 -3. Check the connection status of the sensor 849 - 850 - 851 -= 9. Packing Info = 852 - 853 - 854 854 (% style="color:#037691" %)**Package Includes**: 855 855 856 856 * PS-LB LoRaWAN Pressure Sensor ... ... @@ -862,9 +862,11 @@ 862 862 * Package Size / pcs : cm 863 863 * Weight / pcs : g 864 864 865 -= 10. Support = 866 866 867 867 877 += 9. Support = 878 + 879 + 868 868 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 869 869 870 870 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[Support@dragino.cc>>mailto:Support@dragino.cc]].