Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/27 10:31
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -PS-LB -- 1 +PS-LB --LoRaWAN Air Water Pressure Sensor User Manual - Content
-
... ... @@ -77,7 +77,7 @@ 77 77 78 78 (% style="color:#037691" %)**LoRa Spec:** 79 79 80 -* Frequency Range, Band 1 (HF): 862 ~~ 1020 Mhz 80 +* Frequency Range, Band 1 (HF): 862 ~~ 1020 Mhz,Band 2 (LF): 410 ~~ 528 Mhz 81 81 * Max +22 dBm constant RF output vs. 82 82 * RX sensitivity: down to -139 dBm. 83 83 * Excellent blocking immunity ... ... @@ -385,10 +385,10 @@ 385 385 386 386 387 387 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 388 -|(% style="background-color:#d9e2f3; width:97px" %)((( 388 +|(% style="background-color:#d9e2f3; color:#0070c0; width:97px" %)((( 389 389 **Size(bytes)** 390 -)))|(% style="background-color:#d9e2f3; width:48px" %)**2**|(% style="background-color:#d9e2f3; width:71px" %)**2**|(% style="background-color:#d9e2f3; width:98px" %)**2**|(% style="background-color:#d9e2f3; width:73px" %)**2**|(% style="background-color:#d9e2f3; width:122px" %)**1** 391 -|(% style="width:97px" %) **Value**|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt flag>>||anchor="H2.3.7IN126IN226INTpin"]]390 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:48px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:71px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:98px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:73px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:122px" %)**1** 391 +|(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt flag>>||anchor="H2.3.7IN126IN226INTpin"]] 392 392 393 393 [[image:1675144608950-310.png]] 394 394 ... ... @@ -472,10 +472,10 @@ 472 472 473 473 474 474 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:508.222px" %) 475 -|(% style="background-color:#d9e2f3; width:94px" %)((( 475 +|(% style="background-color:#d9e2f3; color:#0070c0; width:94px" %)((( 476 476 **Size(bytes)** 477 -)))|(% style="background-color:#d9e2f3; width:43px" %)**2**|(% style="background-color:#d9e2f3; width:367px" %)**n** 478 -|(% style="width:94px" %) **Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:367px" %)(((477 +)))|(% style="background-color:#d9e2f3; color:#0070c0; width:43px" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0; width:367px" %)**n** 478 +|(% style="width:94px" %)Value|(% style="width:43px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:367px" %)((( 479 479 Voltage value, each 2 bytes is a set of voltage values. 480 480 ))) 481 481 ... ... @@ -746,17 +746,21 @@ 746 746 747 747 (% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %) 748 748 |(% style="background-color:#d9e2f3; color:#0070c0; width:154px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:269px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Response** 749 -|(% style="background-color:#f2f2f2; width:154px" %)AT 749 +|(% style="background-color:#f2f2f2; width:154px" %)AT+PROBE=?|(% style="background-color:#f2f2f2; width:269px" %)Get or Set the probe model.|(% style="background-color:#f2f2f2" %)0 750 750 OK 751 -|(% style="background-color:#f2f2f2; width:154px" %)AT 751 +|(% style="background-color:#f2f2f2; width:154px" %)AT+PROBE=0003|(% style="background-color:#f2f2f2; width:269px" %)Set water depth sensor mode, 3m type.|(% style="background-color:#f2f2f2" %)OK 752 752 |(% style="background-color:#f2f2f2; width:154px" %)((( 753 -AT 753 +AT+PROBE=000A 754 754 755 755 756 756 )))|(% style="background-color:#f2f2f2; width:269px" %)Set water depth sensor mode, 10m type.|(% style="background-color:#f2f2f2" %)OK 757 -|(% style="background-color:#f2f2f2; width:154px" %)AT +PROBE =0101|(% style="background-color:#f2f2f2; width:269px" %)Set pressure transmitters mode, first type(A).|(% style="background-color:#f2f2f2" %)OK 758 -|(% style="background-color:#f2f2f2; width:154px" %)AT +PROBE =0000|(% style="background-color:#f2f2f2; width:269px" %)Initial state, no settings.|(% style="background-color:#f2f2f2" %)OK 757 +|(% style="background-color:#f2f2f2; width:154px" %)AT+PROBE=0101|(% style="background-color:#f2f2f2; width:269px" %)Set pressure transmitters mode, first type(A).|(% style="background-color:#f2f2f2" %)OK 758 +|(% style="background-color:#f2f2f2; width:154px" %)AT+PROBE=0000|(% style="background-color:#f2f2f2; width:269px" %)Initial state, no settings.|(% style="background-color:#f2f2f2" %)OK 759 +|(% style="background-color:#f2f2f2; width:154px" %)AT+PROBE=0000|(% style="background-color:#f2f2f2; width:269px" %)Initial state, no settings.|(% style="background-color:#f2f2f2" %)OK 759 759 761 + 762 + 763 + 760 760 (% style="color:blue" %)**Downlink Command: 0x08** 761 761 762 762 Format: Command Code (0x08) followed by 2 bytes. ... ... @@ -849,11 +849,16 @@ 849 849 850 850 = 8. Troubleshooting = 851 851 852 -Unable to display water depth in payload 856 +== 8.1 Water Depth Always shows 0 in payload == 857 + 858 + 859 +If your device's IDC_intput_mA is normal, but your reading always shows 0, please refer to the following points: 860 + 853 853 ~1. Please set it to mod1 854 854 2. Please set the command [[AT+PROBE>>http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/PS-LB%20--%20LoRaWAN%20Pressure%20Sensor/#H3.3.4SettheProbeModel]] according to the model of your sensor 855 855 3. Check the connection status of the sensor 856 856 865 + 857 857 = 9. Packing Info = 858 858 859 859