Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/19 17:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -207,6 +207,7 @@ 207 207 ))) 208 208 |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode. 209 209 210 + 210 210 == 1.9 Pin Mapping == 211 211 212 212 ... ... @@ -311,10 +311,10 @@ 311 311 Users can also use the downlink command(0x26 01) to ask PS-LB to resend this uplink. 312 312 313 313 314 -(% border="1" cellspacing="4" style="width:510px" %) 315 -|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0"%)**Device Status (FPORT=5)**316 -|(% style=" background-color:#f2f2f2;width:103px" %)**Size (bytes)**|(% style="background-color:#f2f2f2;width:72px" %)**1**|(% style="background-color:#f2f2f2" %)**2**|(% style="background-color:#f2f2f2;width:91px" %)**1**|(% style="background-color:#f2f2f2;width:86px" %)**1**|(% style="background-color:#f2f2f2;width:44px" %)**2**317 -|(% style=" background-color:#f2f2f2;width:103px" %)**Value**|(% style="background-color:#f2f2f2;width:72px" %)Sensor Model|(% style="background-color:#f2f2f2" %)Firmware Version|(% style="background-color:#f2f2f2;width:91px" %)Frequency Band|(% style="background-color:#f2f2f2;width:86px" %)Sub-band|(% style="background-color:#f2f2f2;width:44px" %)BAT315 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 316 +|(% colspan="6" %)**Device Status (FPORT=5)** 317 +|(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2** 318 +|(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT 318 318 319 319 Example parse in TTNv3 320 320 ... ... @@ -380,11 +380,11 @@ 380 380 Uplink payload includes in total 9 bytes. 381 381 382 382 383 -(% border="1" cellspacing="4" style="background-color:#f 2f2f2; width:510px" %)384 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 384 384 |(% style="width:97px" %)((( 385 385 **Size(bytes)** 386 386 )))|(% style="width:48px" %)**2**|(% style="width:71px" %)**2**|(% style="width:98px" %)**2**|(% style="width:73px" %)**2**|(% style="width:122px" %)**1** 387 -|(% style="width:97px" %) **Value**|(% style="width:48px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.5ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.607E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.707E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt flag>>||anchor="H2.3.8IN126IN226INTpin"]]388 +|(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.5ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.607E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.707E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt flag>>||anchor="H2.3.8IN126IN226INTpin"]] 388 388 389 389 [[image:1675144608950-310.png]] 390 390 ... ... @@ -405,13 +405,13 @@ 405 405 PS-LB has different kind of probe, 4~~20mA represent the full scale of the measuring range. So a 12mA output means different meaning for different probe. 406 406 407 407 408 - **For example.**409 +For example. 409 409 410 -(% border="1" cellspacing="4" style="width:510px" %) 411 -| (% style="background-color:#d9e2f3; color:#0070c0" %)**Part Number**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Probe Used**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4~~20mA scale**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Example: 12mA meaning**412 -| (% style="background-color:#f2f2f2" %)PS-LB-I3|(% style="background-color:#f2f2f2" %)immersion type with 3 meters cable|(% style="background-color:#f2f2f2" %)0~~3 meters|(% style="background-color:#f2f2f2" %)1.5 meters pure water413 -| (% style="background-color:#f2f2f2" %)PS-LB-I5|(% style="background-color:#f2f2f2" %)immersion type with 5 meters cable|(% style="background-color:#f2f2f2" %)0~~5 meters|(% style="background-color:#f2f2f2" %)2.5 meters pure water414 -| (% style="background-color:#f2f2f2" %)PS-LB-T20-B|(% style="background-color:#f2f2f2" %)T20 threaded probe|(% style="background-color:#f2f2f2" %)0~~1MPa|(% style="background-color:#f2f2f2" %)0.5MPa air / gas or water pressure411 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 412 +|**Part Number**|**Probe Used**|**4~~20mA scale**|**Example: 12mA meaning** 413 +|PS-LB-I3|immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water 414 +|PS-LB-I5|immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water 415 +|PS-LB-T20-B|T20 threaded probe|0~~1MPa|0.5MPa air / gas or water pressure 415 415 416 416 The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value. 417 417 ... ... @@ -467,7 +467,7 @@ 467 467 === (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 === 468 468 469 469 470 -(% border="1" cellspacing="4" style="background-color:#f 2f2f2; width:508.222px" %)471 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %) 471 471 |(% style="width:94px" %)((( 472 472 **Size(bytes)** 473 473 )))|(% style="width:43px" %)2|(% style="width:367px" %)n ... ... @@ -566,7 +566,6 @@ 566 566 567 567 == 3.1 Configure Methods == 568 568 569 - 570 570 PS-LB-NA supports below configure method: 571 571 572 572 * AT Command via Bluetooth Connection (**Recommand Way**): [[BLE Configure Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. ... ... @@ -575,7 +575,6 @@ 575 575 576 576 == 3.2 General Commands == 577 577 578 - 579 579 These commands are to configure: 580 580 581 581 * General system settings like: uplink interval. ... ... @@ -599,19 +599,18 @@ 599 599 600 600 (% style="color:blue" %)**AT Command: AT+TDC** 601 601 602 -(% border="1" cellspacing="4" style="width:510px" %) 603 -|=(% style="width: 16 0px;background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Command Example**|=(% style="width: 160px;background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Function**|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)**Response**604 -|(% style=" background-color:#f2f2f2;width:157px" %)AT+TDC=?|(% style="background-color:#f2f2f2;width:166px" %)Show current transmit Interval|(% style="background-color:#f2f2f2" %)(((601 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 602 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response** 603 +|(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|((( 605 605 30000 606 606 OK 607 607 the interval is 30000ms = 30s 608 608 ))) 609 -|(% style=" background-color:#f2f2f2;width:157px" %)AT+TDC=60000|(% style="background-color:#f2f2f2;width:166px" %)Set Transmit Interval|(% style="background-color:#f2f2f2" %)(((608 +|(% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|((( 610 610 OK 611 611 Set transmit interval to 60000ms = 60 seconds 612 612 ))) 613 613 614 - 615 615 (% style="color:blue" %)**Downlink Command: 0x01** 616 616 617 617 Format: Command Code (0x01) followed by 3 bytes time value. ... ... @@ -628,22 +628,21 @@ 628 628 629 629 (% style="color:blue" %)**AT Command: AT+INTMOD** 630 630 631 -(% border="1" cellspacing="4" style="width:510px" %) 632 -|=(% style="width: 154px; background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Response**633 -|(% style=" background-color:#f2f2f2;width:154px" %)AT+INTMOD=?|(% style="background-color:#f2f2f2;width:196px" %)Show current interrupt mode|(% style="background-color:#f2f2f2;width:157px" %)(((629 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 630 +|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 196px;" %)**Function**|=(% style="width: 157px;" %)**Response** 631 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 634 634 0 635 635 OK 636 636 the mode is 0 =Disable Interrupt 637 637 ))) 638 -|(% style=" background-color:#f2f2f2;width:154px" %)AT+INTMOD=2|(% style="background-color:#f2f2f2;width:196px" %)(((636 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 639 639 Set Transmit Interval 640 640 0. (Disable Interrupt), 641 641 ~1. (Trigger by rising and falling edge) 642 642 2. (Trigger by falling edge) 643 643 3. (Trigger by rising edge) 644 -)))|(% style=" background-color:#f2f2f2;width:157px" %)OK642 +)))|(% style="width:157px" %)OK 645 645 646 - 647 647 (% style="color:blue" %)**Downlink Command: 0x06** 648 648 649 649 Format: Command Code (0x06) followed by 3 bytes.