Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/19 17:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -58,7 +58,6 @@ 58 58 * Uplink on periodically 59 59 * Downlink to change configure 60 60 * 8500mAh Battery for long term use 61 -* Controllable 3.3v,5v and 12v output to power external sensor 62 62 63 63 == 1.3 Specification == 64 64 ... ... @@ -133,8 +133,11 @@ 133 133 * Measuring Range: Measure range can be customized, up to 100m. 134 134 * Accuracy: 0.2% F.S 135 135 * Long-Term Stability: ±0.2% F.S / Year 135 +* Overload 200% F.S 136 +* Zero Temperature Drift: ±2% F.S) 137 +* FS Temperature Drift: ±2% F.S 136 136 * Storage temperature: -30℃~~80℃ 137 -* Operating temperature: 0℃~~5 0℃139 +* Operating temperature: -40℃~~85℃ 138 138 * Material: 316 stainless steels 139 139 140 140 == 1.5 Probe Dimension == ... ... @@ -194,18 +194,18 @@ 194 194 [[image:1675071855856-879.png]] 195 195 196 196 197 -(% border="1" cellspacing="4" style="width:510px" %) 198 -|=(% style="width: 167px; background-color:#D9E2F3;color:#0070C0" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 225px;background-color:#D9E2F3;color:#0070C0" %)**Action**199 -|(% style=" background-color:#f2f2f2;width:167px" %)Pressing ACT between 1s < time < 3s|(% style="background-color:#f2f2f2;width:117px" %)Send an uplink|(% style="background-color:#f2f2f2;width:225px" %)(((199 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 200 +|=(% style="width: 167px;" %)**Behavior on ACT**|=(% style="width: 117px;" %)**Function**|=(% style="width: 225px;" %)**Action** 201 +|(% style="width:167px" %)Pressing ACT between 1s < time < 3s|(% style="width:117px" %)Send an uplink|(% style="width:225px" %)((( 200 200 If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, (% style="color:blue" %)**blue led** (%%)will blink once. 201 201 Meanwhile, BLE module will be active and user can connect via BLE to configure device. 202 202 ))) 203 -|(% style=" background-color:#f2f2f2;width:167px" %)Pressing ACT for more than 3s|(% style="background-color:#f2f2f2;width:117px" %)Active Device|(% style="background-color:#f2f2f2;width:225px" %)(((204 -(% style=" background-color:#f2f2f2; color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:#037691" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network.205 -(% style=" background-color:#f2f2f2; color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network.205 +|(% style="width:167px" %)Pressing ACT for more than 3s|(% style="width:117px" %)Active Device|(% style="width:225px" %)((( 206 +(% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:#037691" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. 207 +(% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 206 206 Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network. 207 207 ))) 208 -|(% style=" background-color:#f2f2f2;width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2;width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2;width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NAis in Deep Sleep Mode.210 +|(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode. 209 209 210 210 == 1.9 Pin Mapping == 211 211 ... ... @@ -301,8 +301,18 @@ 301 301 After join success, it will start to upload messages to TTN and you can see the messages in the panel. 302 302 303 303 306 + 304 304 == 2.3 Uplink Payload == 305 305 309 + 310 +Uplink payloads have two types: 311 + 312 +* Distance Value: Use FPORT=2 313 +* Other control commands: Use other FPORT fields. 314 + 315 +The application server should parse the correct value based on FPORT settings. 316 + 317 + 306 306 === 2.3.1 Device Status, FPORT~=5 === 307 307 308 308 ... ... @@ -311,10 +311,10 @@ 311 311 Users can also use the downlink command(0x26 01) to ask PS-LB to resend this uplink. 312 312 313 313 314 -(% border="1" cellspacing="4" style="width:510px" %) 315 -|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0"%)**Device Status (FPORT=5)**316 -|(% style=" background-color:#f2f2f2;width:103px" %)**Size (bytes)**|(% style="background-color:#f2f2f2;width:72px" %)**1**|(% style="background-color:#f2f2f2" %)**2**|(% style="background-color:#f2f2f2;width:91px" %)**1**|(% style="background-color:#f2f2f2;width:86px" %)**1**|(% style="background-color:#f2f2f2;width:44px" %)**2**317 -|(% style=" background-color:#f2f2f2;width:103px" %)**Value**|(% style="background-color:#f2f2f2;width:72px" %)Sensor Model|(% style="background-color:#f2f2f2" %)Firmware Version|(% style="background-color:#f2f2f2;width:91px" %)Frequency Band|(% style="background-color:#f2f2f2;width:86px" %)Sub-band|(% style="background-color:#f2f2f2;width:44px" %)BAT326 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 327 +|(% colspan="6" %)**Device Status (FPORT=5)** 328 +|(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2** 329 +|(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT 318 318 319 319 Example parse in TTNv3 320 320 ... ... @@ -380,18 +380,32 @@ 380 380 Uplink payload includes in total 9 bytes. 381 381 382 382 383 -(% border="1" cellspacing="4" style="background-color:#f 2f2f2; width:510px" %)395 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 384 384 |(% style="width:97px" %)((( 385 385 **Size(bytes)** 386 386 )))|(% style="width:48px" %)**2**|(% style="width:71px" %)**2**|(% style="width:98px" %)**2**|(% style="width:73px" %)**2**|(% style="width:122px" %)**1** 387 -|(% style="width:97px" %) **Value**|(% style="width:48px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.5ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.607E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.707E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt flag>>||anchor="H2.3.8IN126IN226INTpin"]]399 +|(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt flag>>||anchor="H2.3.7IN126IN226INTpin"]] 388 388 389 389 [[image:1675144608950-310.png]] 390 390 391 391 392 -=== 2.3.3 BatteryInfo===404 +=== 2.3.3 Sensor value, FPORT~=7 === 393 393 394 394 407 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %) 408 +|(% style="width:94px" %)((( 409 +**Size(bytes)** 410 +)))|(% style="width:43px" %)2|(% style="width:367px" %)n 411 +|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:367px" %)((( 412 +Voltage value, each 2 bytes is a set of voltage values. 413 +))) 414 + 415 +[[image:image-20230220171300-1.png||height="207" width="863"]] 416 + 417 + 418 +=== 2.3.4 Battery Info === 419 + 420 + 395 395 Check the battery voltage for PS-LB. 396 396 397 397 Ex1: 0x0B45 = 2885mV ... ... @@ -399,27 +399,26 @@ 399 399 Ex2: 0x0B49 = 2889mV 400 400 401 401 402 -=== 2.3. 4Probe Model ===428 +=== 2.3.5 Probe Model === 403 403 404 404 405 -PS-LB has different kind of probe, 4~~20mA represent the full scale of the measuring range. So a 12mA output means different meaning for different probe.431 +PS-LB has different kind of probe, 0~~20mA represent the full scale of the measuring range. So a 15mA output means different meaning for different probe. 406 406 407 407 408 - **For example.**434 +For example. 409 409 410 -(% border="1" cellspacing="4" style="width:510px" %) 411 -|(% style="background-color:#d9e2f3; color:#0070c0" %)**Part Number**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Probe Used**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4~~20mA scale**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Example: 12mA meaning** 412 -|(% style="background-color:#f2f2f2" %)PS-LB-I3|(% style="background-color:#f2f2f2" %)immersion type with 3 meters cable|(% style="background-color:#f2f2f2" %)0~~3 meters|(% style="background-color:#f2f2f2" %)1.5 meters pure water 413 -|(% style="background-color:#f2f2f2" %)PS-LB-I5|(% style="background-color:#f2f2f2" %)immersion type with 5 meters cable|(% style="background-color:#f2f2f2" %)0~~5 meters|(% style="background-color:#f2f2f2" %)2.5 meters pure water 414 -|(% style="background-color:#f2f2f2" %)PS-LB-T20-B|(% style="background-color:#f2f2f2" %)T20 threaded probe|(% style="background-color:#f2f2f2" %)0~~1MPa|(% style="background-color:#f2f2f2" %)0.5MPa air / gas or water pressure 436 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 437 +|(% style="width:111px" %)**Part Number**|(% style="width:158px" %)**Probe Used**|**0~~20mA scale**|**Example: 10mA meaning** 438 +|(% style="width:111px" %)PS-LB-I3|(% style="width:158px" %)immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water 439 +|(% style="width:111px" %)PS-LB-I5|(% style="width:158px" %)immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water 415 415 416 -The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value.441 +The probe model field provides the convenient for server to identical how it should parse the 0~~20mA sensor value and get the correct value. 417 417 418 418 419 -=== 2.3. 50~~20mA value (IDC_IN) ===444 +=== 2.3.6 0~~20mA value (IDC_IN) === 420 420 421 421 422 -The output value from **Pressure Probe**, use together with Probe Model to get the pressure value or water level.447 +The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level. 423 423 424 424 (% style="color:#037691" %)**Example**: 425 425 ... ... @@ -426,14 +426,9 @@ 426 426 27AE(H) = 10158 (D)/1000 = 10.158mA. 427 427 428 428 429 - Insteadofpressure probe, User can also connect a general 4~~20mAin this port to support differenttypesof 4~~20mA sensors. belowis the connectionexample:454 +=== 2.3.7 0~~30V value ( pin VDC_IN) === 430 430 431 -[[image:image-20230225154759-1.png||height="408" width="741"]] 432 432 433 - 434 -=== 2.3.6 0~~30V value ( pin VDC_IN) === 435 - 436 - 437 437 Measure the voltage value. The range is 0 to 30V. 438 438 439 439 (% style="color:#037691" %)**Example**: ... ... @@ -441,7 +441,7 @@ 441 441 138E(H) = 5006(D)/1000= 5.006V 442 442 443 443 444 -=== 2.3. 7IN1&IN2&INT pin ===464 +=== 2.3.8 IN1&IN2&INT pin === 445 445 446 446 447 447 IN1 and IN2 are used as digital input pins. ... ... @@ -464,24 +464,6 @@ 464 464 0x01: Interrupt Uplink Packet. 465 465 466 466 467 -=== (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 === 468 - 469 - 470 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:508.222px" %) 471 -|(% style="width:94px" %)((( 472 -**Size(bytes)** 473 -)))|(% style="width:43px" %)2|(% style="width:367px" %)n 474 -|(% style="width:94px" %)**Value**|(% style="width:43px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:367px" %)((( 475 -Voltage value, each 2 bytes is a set of voltage values. 476 -))) 477 - 478 -[[image:image-20230220171300-1.png||height="207" width="863"]] 479 - 480 -Multiple sets of data collected are displayed in this form: 481 - 482 -[voltage value1], [voltage value2], [voltage value3],…[voltage value n/2] 483 - 484 - 485 485 === 2.3.9 Decode payload in The Things Network === 486 486 487 487 ... ... @@ -562,19 +562,18 @@ 562 562 [[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]] 563 563 564 564 565 -= 3. Configure PS-LB = 566 566 567 -= =3.1ConfigureMethods==568 += 3. Configure PS-LB via AT Command or LoRaWAN Downlink = 568 568 569 569 570 - PS-LB-NAsupports belowconfiguremethod:571 +Use can configure PS-LB via AT Command or LoRaWAN Downlink. 571 571 572 -* AT Command via Bluetooth Connection (**Recommand Way**): [[BLE Configure Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 573 -* AT Command via UART Connection : See [[FAQ>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/#H7.FAQ]]. 574 -* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 573 +* AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]]. 574 +* LoRaWAN Downlink instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 575 575 576 - == 3.2 GeneralCommands==576 +There are two kinds of commands to configure PS-LB, they are: 577 577 578 +* (% style="color:#037691" %)**General Commands** 578 578 579 579 These commands are to configure: 580 580 ... ... @@ -581,18 +581,17 @@ 581 581 * General system settings like: uplink interval. 582 582 * LoRaWAN protocol & radio related command. 583 583 584 -They are same for all Dragino Device swhich support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:585 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 585 585 586 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>> url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]587 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 587 587 588 588 590 +* (% style="color:#037691" %)**Commands special design for PS-LB** 589 589 590 -== 3.3 Commands special design for PS-LB == 591 - 592 592 These commands only valid for PS-LB, as below: 593 593 594 594 595 -== =3.3.1 Set Transmit Interval Time ===595 +== 3.1 Set Transmit Interval Time == 596 596 597 597 598 598 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -599,19 +599,18 @@ 599 599 600 600 (% style="color:blue" %)**AT Command: AT+TDC** 601 601 602 -(% border="1" cellspacing="4" style="width:510px" %) 603 -|=(% style="width: 16 0px;background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Command Example**|=(% style="width: 160px;background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Function**|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)**Response**604 -|(% style=" background-color:#f2f2f2;width:157px" %)AT+TDC=?|(% style="background-color:#f2f2f2;width:166px" %)Show current transmit Interval|(% style="background-color:#f2f2f2" %)(((602 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 603 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response** 604 +|(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|((( 605 605 30000 606 606 OK 607 607 the interval is 30000ms = 30s 608 608 ))) 609 -|(% style=" background-color:#f2f2f2;width:157px" %)AT+TDC=60000|(% style="background-color:#f2f2f2;width:166px" %)Set Transmit Interval|(% style="background-color:#f2f2f2" %)(((609 +|(% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|((( 610 610 OK 611 611 Set transmit interval to 60000ms = 60 seconds 612 612 ))) 613 613 614 - 615 615 (% style="color:blue" %)**Downlink Command: 0x01** 616 616 617 617 Format: Command Code (0x01) followed by 3 bytes time value. ... ... @@ -621,7 +621,7 @@ 621 621 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 622 622 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 623 623 624 -== =3.3.2 Set Interrupt Mode ===623 +== 3.2 Set Interrupt Mode == 625 625 626 626 627 627 Feature, Set Interrupt mode for GPIO_EXIT. ... ... @@ -628,22 +628,21 @@ 628 628 629 629 (% style="color:blue" %)**AT Command: AT+INTMOD** 630 630 631 -(% border="1" cellspacing="4" style="width:510px" %) 632 -|=(% style="width: 154px; background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Response**633 -|(% style=" background-color:#f2f2f2;width:154px" %)AT+INTMOD=?|(% style="background-color:#f2f2f2;width:196px" %)Show current interrupt mode|(% style="background-color:#f2f2f2;width:157px" %)(((630 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 631 +|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 196px;" %)**Function**|=(% style="width: 157px;" %)**Response** 632 +|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)((( 634 634 0 635 635 OK 636 -the mode is 0 = DisableInterrupt635 +the mode is 0 = No interruption 637 637 ))) 638 -|(% style=" background-color:#f2f2f2;width:154px" %)AT+INTMOD=2|(% style="background-color:#f2f2f2;width:196px" %)(((637 +|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)((( 639 639 Set Transmit Interval 640 - 0. (Disable Interrupt),641 - ~1. (Trigger by rising and falling edge)642 - 2. (Trigger by falling edge)643 - 3. (Trigger by rising edge)644 -)))|(% style=" background-color:#f2f2f2;width:157px" %)OK639 +~1. (Disable Interrupt), 640 +2. (Trigger by rising and falling edge) 641 +3. (Trigger by falling edge) 642 +4. (Trigger by rising edge) 643 +)))|(% style="width:157px" %)OK 645 645 646 - 647 647 (% style="color:blue" %)**Downlink Command: 0x06** 648 648 649 649 Format: Command Code (0x06) followed by 3 bytes. ... ... @@ -653,7 +653,7 @@ 653 653 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 654 654 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 655 655 656 -== =3.3.3Set the output time ===654 +== 3.3 Set the output time == 657 657 658 658 659 659 Feature, Control the output 3V3 , 5V or 12V. ... ... @@ -722,111 +722,163 @@ 722 722 * Example 5: Downlink Payload: 070301F4 **~-~-->** AT+12VT=500 723 723 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 724 724 725 -== =3.3.4 Set the Probe Model ===723 +== 3.4 Set the Probe Model == 726 726 727 727 728 - Usersneed to configure thisparameter according to the type of externalprobe. In this way, the servercan decode according to this value, and convert the current valueoutputby the sensor into waterdepthorpressure value.726 +(% style="color:blue" %)**AT Command: AT** **+PROBE** 729 729 730 -**AT Command: AT** **+PROBE** 728 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:448px" %) 729 +|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 204px;" %)**Function**|=(% style="width: 85px;" %)**Response** 730 +|(% style="width:154px" %)AT +PROBE =?|(% style="width:204px" %)Get or Set the probe model.|(% style="width:85px" %)((( 731 +0 732 +OK 733 +))) 734 +|(% style="width:154px" %)AT +PROBE =0003|(% style="width:204px" %)Set water depth sensor mode, 3m type.|(% style="width:85px" %)OK 735 +|(% style="width:154px" %)AT +PROBE =0101|(% style="width:204px" %)Set pressure transmitters mode, first type.|(% style="width:85px" %)((( 736 +OK 737 +))) 738 +|(% style="width:154px" %)AT +PROBE =0000|(% style="width:204px" %)Initial state, no settings.|(% style="width:85px" %)((( 739 +OK 740 +))) 731 731 732 - AT+PROBE=aabb742 +(% style="color:blue" %)**Downlink Command: 0x08** 733 733 734 - Whenaa=00, itis the waterdepthmode,andthe current is converted intothewaterdepthvalue;bbisthe probe ata depth ofseveral meters.744 +Format: Command Code (0x08) followed by 2 bytes. 735 735 736 -When aa=01, it is the pressure mode, which converts the current into a pressure value; 746 +* Example 1: Downlink Payload: 080003 **~-~-->** AT+PROBE=0003 747 +* Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 737 737 738 - bbrepresents which type of pressuresensoritis.749 +== 3.5 Multiple collections are one uplink(Since firmware V1.1) == 739 739 740 -(A->01,B->02,C->03,D->04,E->05,F->06,G->07,H->08,I->09,J->0A,K->0B,L->0C) 741 741 752 +Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time. 753 + 754 +(% style="color:blue" %)**AT Command: AT** **+STDC** 755 + 742 742 (% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 743 -|**Command Example**|**Function**|**Response** 744 -|AT +PROBE =?|Get or Set the probe model.|0 757 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response** 758 +|(% style="width:156px" %)AT+STDC=?|(% style="width:137px" %)((( 759 +Get the mode of multiple acquisitions and one uplink 760 +)))|((( 761 +1,10,18 745 745 OK 746 -|AT +PROBE =0003|Set water depth sensor mode, 3m type.|OK 747 -|((( 748 -AT +PROBE =000A 763 +))) 764 +|(% style="width:156px" %)AT+STDC=1,10,18|(% style="width:137px" %)Set the mode of multiple acquisitions and one uplink|((( 765 +OK 766 +**(% style="color:#037691" %)aa:**(%%) 767 +**0** means disable this function and use TDC to send packets. 768 +**1** means enable this function, use the method of multiple acquisitions to send packets. 769 +**(% style="color:#037691" %)bb:**(%%) Each collection interval (s), the value is 1~~65535 770 +**(% style="color:#037691" %)cc:**(%%)the number of collection times, the value is 1~~120 771 +))) 749 749 750 - 751 -)))|Set water depth sensor mode, 10m type.|OK 752 -|AT +PROBE =0101|Set pressure transmitters mode, first type(A).|OK 753 -|AT +PROBE =0000|Initial state, no settings.|OK 773 +(% style="color:blue" %)**Downlink Command: 0xAE** 754 754 755 - **DownlinkCommand:0x08**775 +Format: Command Code (0x08) followed by 5 bytes. 756 756 757 - Format:CommandCode(0x08)followed by2bytes.777 +* Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 758 758 759 -* Example 1: Downlink Payload: 080003 **~-~-->** AT+PROBE=0003 760 -* Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 779 += 4. Battery & how to replace = 761 761 762 -== =3.3.5Multiple collections areone uplink(Sincefirmware V1.1)===781 +== 4.1 Battery Type == 763 763 764 764 765 - Added AT+STDC command tocollect thevoltageofVDC_INPUTmultiple timesandupload itat onetime.784 +PS-LB is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>https://www.dropbox.com/sh/w9l2oa3ytpculph/AAAPtt-apH4lYfCj-2Y6lHvQa?dl=0]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 766 766 767 - (%style="color:blue"%)**ATCommand: AT** **+STDC**786 +The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 768 768 769 - AT+STDC=aa,bb,bb788 +[[image:1675146710956-626.png]] 770 770 771 -(% style="color:#037691" %)**aa:**(%%) 772 -**0:** means disable this function and use TDC to send packets. 773 -**1:** means enable this function, use the method of multiple acquisitions to send packets. 774 -(% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535 775 -(% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120 776 776 777 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 778 -|**Command Example**|**Function**|**Response** 779 -|AT+STDC=?|Get the mode of multiple acquisitions and one uplink.|1,10,18 780 -OK 781 -|AT+STDC=1,10,18|Set the mode of multiple acquisitions and one uplink, collect once every 10 seconds, and report after 18 times.|((( 782 -Attention:Take effect after ATZ 791 +Minimum Working Voltage for the PS-LB: 783 783 784 -OK 785 -))) 786 -|AT+STDC=0, 0,0|((( 787 -Use the TDC interval to send packets.(default) 793 +PS-LB: 2.45v ~~ 3.6v 788 788 789 - 790 -)))|((( 791 -Attention:Take effect after ATZ 792 792 793 -OK 794 -))) 796 +== 4.2 Replace Battery == 795 795 796 -(% style="color:blue" %)**Downlink Command: 0xAE** 797 797 798 - Format:CommandCode(0x08)followedby5bytes.799 +Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 799 799 800 - *Example1:DownlinkPayload: AE010258 12** ~-~-->** AT+STDC=1,600,18801 +And make sure the positive and negative pins match. 801 801 802 -= 4. Battery & Power Consumption = 803 803 804 - PS-LB-NAuses ER26500 + SPC1520 battery pack.See belowlink fordetail informationabout the battery infoand how to replace.804 +== 4.3 Power Consumption Analyze == 805 805 806 - [[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 807 807 807 +Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 808 808 809 - =5.OTA firmwareupdate=809 +Instruction to use as below: 810 810 811 +(% style="color:blue" %)**Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0>>https://www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0]] 811 811 813 +(% style="color:blue" %)**Step 2:**(%%) Open it and choose 814 + 815 +* Product Model 816 +* Uplink Interval 817 +* Working Mode 818 + 819 +And the Life expectation in difference case will be shown on the right. 820 + 821 +[[image:1675146895108-304.png]] 822 + 823 + 824 +The battery related documents as below: 825 + 826 +* [[Battery Dimension>>https://www.dropbox.com/s/ox5g9njwjle7aw3/LSN50-Battery-Dimension.pdf?dl=0]], 827 +* [[Lithium-Thionyl Chloride Battery datasheet, Tech Spec>>https://www.dropbox.com/sh/d4oyfnp8o94180o/AABQewCNSh5GPeQH86UxRgQQa?dl=0]] 828 +* [[Lithium-ion Battery-Capacitor datasheet>>https://www.dropbox.com/s/791gjes2lcbfi1p/SPC_1520_datasheet.jpg?dl=0]], [[Tech Spec>>https://www.dropbox.com/s/4pkepr9qqqvtzf2/SPC1520%20Technical%20Specification20171123.pdf?dl=0]] 829 + 830 +[[image:image-20230131145708-3.png]] 831 + 832 + 833 +=== 4.3.1 Battery Note === 834 + 835 + 836 +The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 837 + 838 + 839 +=== 4.3.2 Replace the battery === 840 + 841 + 842 +You can change the battery in the PS-LB.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 843 + 844 +The default battery pack of PS-LB includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 845 + 846 + 847 += 5. Remote Configure device = 848 + 849 +== 5.1 Connect via BLE == 850 + 851 + 852 +Please see this instruction for how to configure via BLE: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]] 853 + 854 + 855 +== 5.2 AT Command Set == 856 + 857 + 858 + 859 += 6. OTA firmware update = 860 + 861 + 812 812 Please see this link for how to do OTA firmware update: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 813 813 814 814 815 -= 6. FAQ =865 += 7. FAQ = 816 816 817 -== 6.1 How to use AT Commandvia UARTto access device? ==867 +== 7.1 How to use AT Command to access device? == 818 818 819 819 820 820 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 821 821 822 822 823 -== 6.2 How to update firmware via UART port? ==873 +== 7.2 How to update firmware via UART port? == 824 824 825 825 826 826 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 827 827 828 828 829 -== 6.3 How to change the LoRa Frequency Bands/Region? ==879 +== 7.3 How to change the LoRa Frequency Bands/Region? == 830 830 831 831 832 832 You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]. ... ... @@ -833,13 +833,13 @@ 833 833 When downloading the images, choose the required image file for download. 834 834 835 835 836 -= 7. Order Info =886 += 8. Order Info = 837 837 838 838 839 839 [[image:image-20230131153105-4.png]] 840 840 841 841 842 -= 8. Packing Info =892 += 9. Packing Info = 843 843 844 844 845 845 (% style="color:#037691" %)**Package Includes**: ... ... @@ -853,7 +853,7 @@ 853 853 * Package Size / pcs : cm 854 854 * Weight / pcs : g 855 855 856 -= 9. Support =906 += 10. Support = 857 857 858 858 859 859 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
- image-20230222174559-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -19.4 KB - Content
- image-20230225154759-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -468.9 KB - Content