405 405  PS-LB has different kind of probe, 4~~20mA represent the full scale of the measuring range. So a 12mA output means different meaning for different probe. 
406 406  
407 407  
408 -**For example.**
408 +For example.
409 409  
410 -(% border="1" cellspacing="4" style="width:510px" %)
411 -|(% style="background-color:#d9e2f3; color:#0070c0" %)**Part Number**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Probe Used**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4~~20mA scale**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Example: 12mA meaning**
412 -|(% style="background-color:#f2f2f2" %)PS-LB-I3|(% style="background-color:#f2f2f2" %)immersion type with 3 meters cable|(% style="background-color:#f2f2f2" %)0~~3 meters|(% style="background-color:#f2f2f2" %)1.5 meters pure water
413 -|(% style="background-color:#f2f2f2" %)PS-LB-I5|(% style="background-color:#f2f2f2" %)immersion type with 5 meters cable|(% style="background-color:#f2f2f2" %)0~~5 meters|(% style="background-color:#f2f2f2" %)2.5 meters pure water
414 -|(% style="background-color:#f2f2f2" %)PS-LB-T20-B|(% style="background-color:#f2f2f2" %)T20 threaded probe|(% style="background-color:#f2f2f2" %)0~~1MPa|(% style="background-color:#f2f2f2" %)0.5MPa air / gas or water pressure
410 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
411 +|**Part Number**|**Probe Used**|**4~~20mA scale**|**Example: 12mA meaning**
412 +|PS-LB-I3|immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water
413 +|PS-LB-I5|immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water
414 +|PS-LB-T20-B|T20 threaded probe|0~~1MPa|0.5MPa air / gas or water pressure
415 415  
416 416  The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value.
417 417  
... ... @@ -467,7 +467,7 @@
467 467  === (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 ===
468 468  
469 469  
470 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:508.222px" %)
470 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %)
471 471  |(% style="width:94px" %)(((
472 472  **Size(bytes)**
473 473  )))|(% style="width:43px" %)2|(% style="width:367px" %)n
... ... @@ -566,7 +566,6 @@
566 566  
567 567  == 3.1 Configure Methods ==
568 568  
569 -
570 570  PS-LB-NA supports below configure method:
571 571  
572 572  * AT Command via Bluetooth Connection (**Recommand Way**): [[BLE Configure Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]].
... ... @@ -575,7 +575,6 @@
575 575  
576 576  == 3.2 General Commands ==
577 577  
578 -
579 579  These commands are to configure:
580 580  
581 581  * General system settings like: uplink interval.
... ... @@ -599,19 +599,18 @@
599 599  
600 600  (% style="color:blue" %)**AT Command: AT+TDC**
601 601  
602 -(% border="1" cellspacing="4" style="width:510px" %)
603 -|=(% style="width: 160px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Command Example**|=(% style="width: 160px; background-color: rgb(217, 226, 243); color: rgb(0, 112, 192);" %)**Function**|=(% style="width: 190px;background-color:#D9E2F3;color:#0070C0" %)**Response**
604 -|(% style="background-color:#f2f2f2; width:157px" %)AT+TDC=?|(% style="background-color:#f2f2f2; width:166px" %)Show current transmit Interval|(% style="background-color:#f2f2f2" %)(((
600 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
601 +|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 137px;" %)**Function**|=**Response**
602 +|(% style="width:156px" %)AT+TDC=?|(% style="width:137px" %)Show current transmit Interval|(((
605 605  30000
606 606  OK
607 607  the interval is 30000ms = 30s
608 608  )))
609 -|(% style="background-color:#f2f2f2; width:157px" %)AT+TDC=60000|(% style="background-color:#f2f2f2; width:166px" %)Set Transmit Interval|(% style="background-color:#f2f2f2" %)(((
607 +|(% style="width:156px" %)AT+TDC=60000|(% style="width:137px" %)Set Transmit Interval|(((
610 610  OK
611 611  Set transmit interval to 60000ms = 60 seconds
612 612  )))
613 613  
614 -
615 615  (% style="color:blue" %)**Downlink Command: 0x01**
616 616  
617 617  Format: Command Code (0x01) followed by 3 bytes time value.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved