... ... @@ -611,7 +611,6 @@
611 611  Set transmit interval to 60000ms = 60 seconds
612 612  )))
613 613  
614 -
615 615  (% style="color:blue" %)**Downlink Command: 0x01**
616 616  
617 617  Format: Command Code (0x01) followed by 3 bytes time value.
... ... @@ -628,20 +628,20 @@
628 628  
629 629  (% style="color:blue" %)**AT Command: AT+INTMOD**
630 630  
631 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
632 -|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 196px;" %)**Function**|=(% style="width: 157px;" %)**Response**
633 -|(% style="width:154px" %)AT+INTMOD=?|(% style="width:196px" %)Show current interrupt mode|(% style="width:157px" %)(((
630 +(% border="1" cellspacing="4" style="width:510px" %)
631 +|=(% style="width: 154px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 157px;background-color:#D9E2F3;color:#0070C0" %)**Response**
632 +|(% style="background-color:#f2f2f2; width:154px" %)AT+INTMOD=?|(% style="background-color:#f2f2f2; width:196px" %)Show current interrupt mode|(% style="background-color:#f2f2f2; width:157px" %)(((
634 634  0
635 635  OK
636 636  the mode is 0 =Disable Interrupt
637 637  )))
638 -|(% style="width:154px" %)AT+INTMOD=2|(% style="width:196px" %)(((
637 +|(% style="background-color:#f2f2f2; width:154px" %)AT+INTMOD=2|(% style="background-color:#f2f2f2; width:196px" %)(((
639 639  Set Transmit Interval
640 640  0. (Disable Interrupt),
641 641  ~1. (Trigger by rising and falling edge)
642 642  2. (Trigger by falling edge)
643 643  3. (Trigger by rising edge)
644 -)))|(% style="width:157px" %)OK
643 +)))|(% style="background-color:#f2f2f2; width:157px" %)OK
645 645  
646 646  (% style="color:blue" %)**Downlink Command: 0x06**
647 647  
... ... @@ -659,52 +659,52 @@
659 659  
660 660  (% style="color:blue" %)**AT Command: AT+3V3T**
661 661  
662 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:474px" %)
663 -|=(% style="width: 154px;" %)**Command Example**|=(% style="width: 201px;" %)**Function**|=(% style="width: 116px;" %)**Response**
664 -|(% style="width:154px" %)AT+3V3T=?|(% style="width:201px" %)Show 3V3 open time.|(% style="width:116px" %)(((
661 +(% border="1" cellspacing="4" style="width:474px" %)
662 +|=(% style="width: 154px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 201px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 116px;background-color:#D9E2F3;color:#0070C0" %)**Response**
663 +|(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=?|(% style="background-color:#f2f2f2; width:201px" %)Show 3V3 open time.|(% style="background-color:#f2f2f2; width:116px" %)(((
665 665  0
666 666  OK
667 667  )))
668 -|(% style="width:154px" %)AT+3V3T=0|(% style="width:201px" %)Normally open 3V3 power supply.|(% style="width:116px" %)(((
667 +|(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=0|(% style="background-color:#f2f2f2; width:201px" %)Normally open 3V3 power supply.|(% style="background-color:#f2f2f2; width:116px" %)(((
669 669  OK
670 670  default setting
671 671  )))
672 -|(% style="width:154px" %)AT+3V3T=1000|(% style="width:201px" %)Close after a delay of 1000 milliseconds.|(% style="width:116px" %)(((
671 +|(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=1000|(% style="background-color:#f2f2f2; width:201px" %)Close after a delay of 1000 milliseconds.|(% style="background-color:#f2f2f2; width:116px" %)(((
673 673  OK
674 674  )))
675 -|(% style="width:154px" %)AT+3V3T=65535|(% style="width:201px" %)Normally closed 3V3 power supply.|(% style="width:116px" %)(((
674 +|(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=65535|(% style="background-color:#f2f2f2; width:201px" %)Normally closed 3V3 power supply.|(% style="background-color:#f2f2f2; width:116px" %)(((
676 676  OK
677 677  )))
678 678  
679 679  (% style="color:blue" %)**AT Command: AT+5VT**
680 680  
681 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:470px" %)
682 -|=(% style="width: 155px;" %)**Command Example**|=(% style="width: 196px;" %)**Function**|=(% style="width: 114px;" %)**Response**
683 -|(% style="width:155px" %)AT+5VT=?|(% style="width:196px" %)Show 5V open time.|(% style="width:114px" %)(((
680 +(% border="1" cellspacing="4" style="width:470px" %)
681 +|=(% style="width: 155px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 196px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 114px;background-color:#D9E2F3;color:#0070C0" %)**Response**
682 +|(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=?|(% style="background-color:#f2f2f2; width:196px" %)Show 5V open time.|(% style="background-color:#f2f2f2; width:114px" %)(((
684 684  0
685 685  OK
686 686  )))
687 -|(% style="width:155px" %)AT+5VT=0|(% style="width:196px" %)Normally closed 5V power supply.|(% style="width:114px" %)(((
686 +|(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=0|(% style="background-color:#f2f2f2; width:196px" %)Normally closed 5V power supply.|(% style="background-color:#f2f2f2; width:114px" %)(((
688 688  OK
689 689  default setting
690 690  )))
691 -|(% style="width:155px" %)AT+5VT=1000|(% style="width:196px" %)Close after a delay of 1000 milliseconds.|(% style="width:114px" %)(((
690 +|(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=1000|(% style="background-color:#f2f2f2; width:196px" %)Close after a delay of 1000 milliseconds.|(% style="background-color:#f2f2f2; width:114px" %)(((
692 692  OK
693 693  )))
694 -|(% style="width:155px" %)AT+5VT=65535|(% style="width:196px" %)Normally open 5V power supply.|(% style="width:114px" %)(((
693 +|(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=65535|(% style="background-color:#f2f2f2; width:196px" %)Normally open 5V power supply.|(% style="background-color:#f2f2f2; width:114px" %)(((
695 695  OK
696 696  )))
697 697  
698 698  (% style="color:blue" %)**AT Command: AT+12VT**
699 699  
700 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:443px" %)
701 -|=(% style="width: 156px;" %)**Command Example**|=(% style="width: 199px;" %)**Function**|=(% style="width: 83px;" %)**Response**
702 -|(% style="width:156px" %)AT+12VT=?|(% style="width:199px" %)Show 12V open time.|(% style="width:83px" %)(((
699 +(% border="1" cellspacing="4" style="width:443px" %)
700 +|=(% style="width: 156px;background-color:#D9E2F3;color:#0070C0" %)**Command Example**|=(% style="width: 199px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 83px;background-color:#D9E2F3;color:#0070C0" %)**Response**
701 +|(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=?|(% style="background-color:#f2f2f2; width:199px" %)Show 12V open time.|(% style="background-color:#f2f2f2; width:83px" %)(((
703 703  0
704 704  OK
705 705  )))
706 -|(% style="width:156px" %)AT+12VT=0|(% style="width:199px" %)Normally closed 12V power supply.|(% style="width:83px" %)OK
707 -|(% style="width:156px" %)AT+12VT=500|(% style="width:199px" %)Close after a delay of 500 milliseconds.|(% style="width:83px" %)(((
705 +|(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=0|(% style="background-color:#f2f2f2; width:199px" %)Normally closed 12V power supply.|(% style="background-color:#f2f2f2; width:83px" %)OK
706 +|(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=500|(% style="background-color:#f2f2f2; width:199px" %)Close after a delay of 500 milliseconds.|(% style="background-color:#f2f2f2; width:83px" %)(((
708 708  OK
709 709  )))
710 710  
... ... @@ -738,18 +738,18 @@
738 738  
739 739  (A->01,B->02,C->03,D->04,E->05,F->06,G->07,H->08,I->09,J->0A,K->0B,L->0C)
740 740  
741 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
742 -|**Command Example**|**Function**|**Response**
743 -|AT +PROBE =?|Get or Set the probe model.|0
740 +(% border="1" cellspacing="4" style="width:510px" %)
741 +|(% style="background-color:#d9e2f3; color:#0070c0; width:154px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:269px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Response**
742 +|(% style="background-color:#f2f2f2; width:154px" %)AT +PROBE =?|(% style="background-color:#f2f2f2; width:269px" %)Get or Set the probe model.|(% style="background-color:#f2f2f2" %)0
744 744  OK
745 -|AT +PROBE =0003|Set water depth sensor mode, 3m type.|OK
746 -|(((
744 +|(% style="background-color:#f2f2f2; width:154px" %)AT +PROBE =0003|(% style="background-color:#f2f2f2; width:269px" %)Set water depth sensor mode, 3m type.|(% style="background-color:#f2f2f2" %)OK
745 +|(% style="background-color:#f2f2f2; width:154px" %)(((
747 747  AT +PROBE =000A
748 748  
749 749  
750 -)))|Set water depth sensor mode, 10m type.|OK
751 -|AT +PROBE =0101|Set pressure transmitters mode, first type(A).|OK
752 -|AT +PROBE =0000|Initial state, no settings.|OK
749 +)))|(% style="background-color:#f2f2f2; width:269px" %)Set water depth sensor mode, 10m type.|(% style="background-color:#f2f2f2" %)OK
750 +|(% style="background-color:#f2f2f2; width:154px" %)AT +PROBE =0101|(% style="background-color:#f2f2f2; width:269px" %)Set pressure transmitters mode, first type(A).|(% style="background-color:#f2f2f2" %)OK
751 +|(% style="background-color:#f2f2f2; width:154px" %)AT +PROBE =0000|(% style="background-color:#f2f2f2; width:269px" %)Initial state, no settings.|(% style="background-color:#f2f2f2" %)OK
753 753  
754 754  **Downlink Command: 0x08**
755 755  
... ... @@ -773,20 +773,20 @@
773 773  (% style="color:#037691" %)**bb:**(%%) Each collection interval (s), the value is 1~~65535
774 774  (% style="color:#037691" %)**cc:**(%%)** **the number of collection times, the value is 1~~120
775 775  
776 -(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
777 -|**Command Example**|**Function**|**Response**
778 -|AT+STDC=?|Get the mode of multiple acquisitions and one uplink.|1,10,18
775 +(% border="1" cellspacing="4" style="width:510px" %)
776 +|(% style="background-color:#d9e2f3; color:#0070c0; width:160px" %)**Command Example**|(% style="background-color:#d9e2f3; color:#0070c0; width:215px" %)**Function**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Response**
777 +|(% style="background-color:#f2f2f2; width:160px" %)AT+STDC=?|(% style="background-color:#f2f2f2; width:215px" %)Get the mode of multiple acquisitions and one uplink.|(% style="background-color:#f2f2f2" %)1,10,18
779 779  OK
780 -|AT+STDC=1,10,18|Set the mode of multiple acquisitions and one uplink, collect once every 10 seconds, and report after 18 times.|(((
779 +|(% style="background-color:#f2f2f2; width:160px" %)AT+STDC=1,10,18|(% style="background-color:#f2f2f2; width:215px" %)Set the mode of multiple acquisitions and one uplink, collect once every 10 seconds, and report after 18 times.|(% style="background-color:#f2f2f2" %)(((
781 781  Attention:Take effect after ATZ
782 782  
783 783  OK
784 784  )))
785 -|AT+STDC=0, 0,0|(((
784 +|(% style="background-color:#f2f2f2; width:160px" %)AT+STDC=0, 0,0|(% style="background-color:#f2f2f2; width:215px" %)(((
786 786  Use the TDC interval to send packets.(default)
787 787  
788 788  
789 -)))|(((
788 +)))|(% style="background-color:#f2f2f2" %)(((
790 790  Attention:Take effect after ATZ
791 791  
792 792  OK
... ... @@ -800,9 +800,10 @@
800 800  
801 801  = 4. Battery & Power Consumption =
802 802  
802 +
803 803  PS-LB-NA uses ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace.
804 804  
805 - [[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
805 +[[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] .
806 806  
807 807  
808 808  = 5. OTA firmware update =
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0