... ... @@ -207,6 +207,7 @@
207 207  )))
208 208  |(% style="background-color:#f2f2f2; width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2; width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2; width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NA is in Deep Sleep Mode.
209 209  
210 +
210 210  == 1.9 Pin Mapping ==
211 211  
212 212  
... ... @@ -316,6 +316,7 @@
316 316  |(% style="background-color:#f2f2f2; width:103px" %)**Size (bytes)**|(% style="background-color:#f2f2f2; width:72px" %)**1**|(% style="background-color:#f2f2f2" %)**2**|(% style="background-color:#f2f2f2; width:91px" %)**1**|(% style="background-color:#f2f2f2; width:86px" %)**1**|(% style="background-color:#f2f2f2; width:44px" %)**2**
317 317  |(% style="background-color:#f2f2f2; width:103px" %)**Value**|(% style="background-color:#f2f2f2; width:72px" %)Sensor Model|(% style="background-color:#f2f2f2" %)Firmware Version|(% style="background-color:#f2f2f2; width:91px" %)Frequency Band|(% style="background-color:#f2f2f2; width:86px" %)Sub-band|(% style="background-color:#f2f2f2; width:44px" %)BAT
318 318  
320 +
319 319  Example parse in TTNv3
320 320  
321 321  [[image:1675144504430-490.png]]
... ... @@ -380,11 +380,11 @@
380 380  Uplink payload includes in total 9 bytes.
381 381  
382 382  
383 -(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
385 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
384 384  |(% style="width:97px" %)(((
385 385  **Size(bytes)**
386 386  )))|(% style="width:48px" %)**2**|(% style="width:71px" %)**2**|(% style="width:98px" %)**2**|(% style="width:73px" %)**2**|(% style="width:122px" %)**1**
387 -|(% style="width:97px" %)**Value**|(% style="width:48px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.5ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.607E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.707E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt  flag>>||anchor="H2.3.8IN126IN226INTpin"]]
389 +|(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.4BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.5ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.607E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.707E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)[[IN1 &IN2 Interrupt  flag>>||anchor="H2.3.8IN126IN226INTpin"]]
388 388  
389 389  [[image:1675144608950-310.png]]
390 390  
... ... @@ -405,13 +405,13 @@
405 405  PS-LB has different kind of probe, 4~~20mA represent the full scale of the measuring range. So a 12mA output means different meaning for different probe. 
406 406  
407 407  
408 -**For example.**
410 +For example.
409 409  
410 -(% border="1" cellspacing="4" style="width:510px" %)
411 -|(% style="background-color:#d9e2f3; color:#0070c0" %)**Part Number**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Probe Used**|(% style="background-color:#d9e2f3; color:#0070c0" %)**4~~20mA scale**|(% style="background-color:#d9e2f3; color:#0070c0" %)**Example: 12mA meaning**
412 -|(% style="background-color:#f2f2f2" %)PS-LB-I3|(% style="background-color:#f2f2f2" %)immersion type with 3 meters cable|(% style="background-color:#f2f2f2" %)0~~3 meters|(% style="background-color:#f2f2f2" %)1.5 meters pure water
413 -|(% style="background-color:#f2f2f2" %)PS-LB-I5|(% style="background-color:#f2f2f2" %)immersion type with 5 meters cable|(% style="background-color:#f2f2f2" %)0~~5 meters|(% style="background-color:#f2f2f2" %)2.5 meters pure water
414 -|(% style="background-color:#f2f2f2" %)PS-LB-T20-B|(% style="background-color:#f2f2f2" %)T20 threaded probe|(% style="background-color:#f2f2f2" %)0~~1MPa|(% style="background-color:#f2f2f2" %)0.5MPa air / gas or water pressure
412 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %)
413 +|**Part Number**|**Probe Used**|**4~~20mA scale**|**Example: 12mA meaning**
414 +|PS-LB-I3|immersion type with 3 meters cable|0~~3 meters|1.5 meters pure water
415 +|PS-LB-I5|immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water
416 +|PS-LB-T20-B|T20 threaded probe|0~~1MPa|0.5MPa air / gas or water pressure
415 415  
416 416  The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value.
417 417  
... ... @@ -467,7 +467,7 @@
467 467  === (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 ===
468 468  
469 469  
470 -(% border="1" cellspacing="4" style="background-color:#F2F2F2; width:508.222px" %)
472 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:508.222px" %)
471 471  |(% style="width:94px" %)(((
472 472  **Size(bytes)**
473 473  )))|(% style="width:43px" %)2|(% style="width:367px" %)n
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0