Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/19 17:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -133,8 +133,11 @@ 133 133 * Measuring Range: Measure range can be customized, up to 100m. 134 134 * Accuracy: 0.2% F.S 135 135 * Long-Term Stability: ±0.2% F.S / Year 136 +* Overload 200% F.S 137 +* Zero Temperature Drift: ±2% F.S) 138 +* FS Temperature Drift: ±2% F.S 136 136 * Storage temperature: -30℃~~80℃ 137 -* Operating temperature: 0℃~~5 0℃140 +* Operating temperature: -40℃~~85℃ 138 138 * Material: 316 stainless steels 139 139 140 140 == 1.5 Probe Dimension == ... ... @@ -194,20 +194,19 @@ 194 194 [[image:1675071855856-879.png]] 195 195 196 196 197 -(% border="1" cellspacing="4" style="width:510px" %) 198 -|=(% style="width: 167px; background-color:#D9E2F3;color:#0070C0" %)**Behavior on ACT**|=(% style="width: 117px;background-color:#D9E2F3;color:#0070C0" %)**Function**|=(% style="width: 225px;background-color:#D9E2F3;color:#0070C0" %)**Action**199 -|(% style=" background-color:#f2f2f2;width:167px" %)Pressing ACT between 1s < time < 3s|(% style="background-color:#f2f2f2;width:117px" %)Send an uplink|(% style="background-color:#f2f2f2;width:225px" %)(((200 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 201 +|=(% style="width: 167px;" %)**Behavior on ACT**|=(% style="width: 117px;" %)**Function**|=(% style="width: 225px;" %)**Action** 202 +|(% style="width:167px" %)Pressing ACT between 1s < time < 3s|(% style="width:117px" %)Send an uplink|(% style="width:225px" %)((( 200 200 If sensor is already Joined to LoRaWAN network, sensor will send an uplink packet, (% style="color:blue" %)**blue led** (%%)will blink once. 201 201 Meanwhile, BLE module will be active and user can connect via BLE to configure device. 202 202 ))) 203 -|(% style=" background-color:#f2f2f2;width:167px" %)Pressing ACT for more than 3s|(% style="background-color:#f2f2f2;width:117px" %)Active Device|(% style="background-color:#f2f2f2;width:225px" %)(((204 -(% style=" background-color:#f2f2f2; color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:#037691" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network.205 -(% style=" background-color:#f2f2f2; color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network.206 +|(% style="width:167px" %)Pressing ACT for more than 3s|(% style="width:117px" %)Active Device|(% style="width:225px" %)((( 207 +(% style="color:green" %)**Green led**(%%) will fast blink 5 times, device will enter (% style="color:#037691" %)**OTA mode**(%%) for 3 seconds. And then start to JOIN LoRaWAN network. 208 +(% style="color:green" %)**Green led**(%%) will solidly turn on for 5 seconds after joined in network. 206 206 Once sensor is active, BLE module will be active and user can connect via BLE to configure device, no matter if device join or not join LoRaWAN network. 207 207 ))) 208 -|(% style=" background-color:#f2f2f2;width:167px" %)Fast press ACT 5 times.|(% style="background-color:#f2f2f2;width:117px" %)Deactivate Device|(% style="background-color:#f2f2f2;width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB-NAis in Deep Sleep Mode.211 +|(% style="width:167px" %)Fast press ACT 5 times.|(% style="width:117px" %)Deactivate Device|(% style="width:225px" %)(% style="color:red" %)**Red led**(%%) will solid on for 5 seconds. Means PS-LB is in Deep Sleep Mode. 209 209 210 - 211 211 == 1.9 Pin Mapping == 212 212 213 213 ... ... @@ -312,12 +312,11 @@ 312 312 Users can also use the downlink command(0x26 01) to ask PS-LB to resend this uplink. 313 313 314 314 315 -(% border="1" cellspacing="4" style="width:510px" %) 316 -|(% colspan="6" style="background-color:#d9e2f3; color:#0070c0"%)**Device Status (FPORT=5)**317 -|(% style=" background-color:#f2f2f2;width:103px" %)**Size (bytes)**|(% style="background-color:#f2f2f2;width:72px" %)**1**|(% style="background-color:#f2f2f2" %)**2**|(% style="background-color:#f2f2f2;width:91px" %)**1**|(% style="background-color:#f2f2f2;width:86px" %)**1**|(% style="background-color:#f2f2f2;width:44px" %)**2**318 -|(% style=" background-color:#f2f2f2;width:103px" %)**Value**|(% style="background-color:#f2f2f2;width:72px" %)Sensor Model|(% style="background-color:#f2f2f2" %)Firmware Version|(% style="background-color:#f2f2f2;width:91px" %)Frequency Band|(% style="background-color:#f2f2f2;width:86px" %)Sub-band|(% style="background-color:#f2f2f2;width:44px" %)BAT317 +(% border="1" cellspacing="4" style="background-color:#f7faff; color:black; width:510px" %) 318 +|(% colspan="6" %)**Device Status (FPORT=5)** 319 +|(% style="width:103px" %)**Size (bytes)**|(% style="width:72px" %)**1**|**2**|(% style="width:91px" %)**1**|(% style="width:86px" %)**1**|(% style="width:44px" %)**2** 320 +|(% style="width:103px" %)**Value**|(% style="width:72px" %)Sensor Model|Firmware Version|(% style="width:91px" %)Frequency Band|(% style="width:86px" %)Sub-band|(% style="width:44px" %)BAT 319 319 320 - 321 321 Example parse in TTNv3 322 322 323 323 [[image:1675144504430-490.png]] ... ... @@ -391,6 +391,9 @@ 391 391 [[image:1675144608950-310.png]] 392 392 393 393 395 +=== === 396 + 397 + 394 394 === 2.3.3 Battery Info === 395 395 396 396 ... ... @@ -415,6 +415,7 @@ 415 415 |PS-LB-I5|immersion type with 5 meters cable|0~~5 meters|2.5 meters pure water 416 416 |PS-LB-T20-B|T20 threaded probe|0~~1MPa|0.5MPa air / gas or water pressure 417 417 422 + 418 418 The probe model field provides the convenient for server to identical how it should parse the 4~~20mA sensor value and get the correct value. 419 419 420 420 ... ... @@ -421,7 +421,7 @@ 421 421 === 2.3.5 0~~20mA value (IDC_IN) === 422 422 423 423 424 -The output value from **Pressure Probe**, use together with Probe Model to get the pressure value or water level.429 +The output value from Pressure Probe, use together with Probe Model to get the pressure value or water level. 425 425 426 426 (% style="color:#037691" %)**Example**: 427 427 ... ... @@ -428,11 +428,6 @@ 428 428 27AE(H) = 10158 (D)/1000 = 10.158mA. 429 429 430 430 431 -Instead of pressure probe, User can also connect a general 4~~20mA in this port to support different types of 4~~20mA sensors. below is the connection example: 432 - 433 -[[image:image-20230225154759-1.png||height="408" width="741"]] 434 - 435 - 436 436 === 2.3.6 0~~30V value ( pin VDC_IN) === 437 437 438 438 ... ... @@ -465,7 +465,6 @@ 465 465 466 466 0x01: Interrupt Uplink Packet. 467 467 468 - 469 469 === (% id="cke_bm_109176S" style="display:none" %) (%%)2.3.8 Sensor value, FPORT~=7 === 470 470 471 471 ... ... @@ -564,35 +564,34 @@ 564 564 [[https:~~/~~/www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0>>url:https://www.dropbox.com/sh/gf1glloczbzz19h/AABbuYI4WY6VdAmpXo6o1V2Ka?dl=0]] 565 565 566 566 567 -= 3. Configure PS-LB = 566 += 3. Configure PS-LB via AT Command or LoRaWAN Downlink = 568 568 569 -== 3.1 Configure Methods == 570 570 571 - PS-LB-NAsupports belowconfiguremethod:569 +Use can configure PS-LB via AT Command or LoRaWAN Downlink. 572 572 573 -* AT Command via Bluetooth Connection (**Recommand Way**): [[BLE Configure Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]]. 574 -* AT Command via UART Connection : See [[FAQ>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/D20-LBD22-LBD23-LB_LoRaWAN_Temperature_Sensor_User_Manual/#H7.FAQ]]. 575 -* LoRaWAN Downlink. Instruction for different platforms: See [[IoT LoRaWAN Server>>url:http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 571 +* AT Command Connection: See [[FAQ>>||anchor="H7.FAQ"]]. 572 +* LoRaWAN Downlink instruction for different platforms: See [[IoT LoRaWAN Server>>http://wiki.dragino.com/xwiki/bin/view/Main/]] section. 576 576 577 - == 3.2 GeneralCommands==574 +There are two kinds of commands to configure PS-LB, they are: 578 578 576 +* (% style="color:#037691" %)**General Commands** 577 + 579 579 These commands are to configure: 580 580 581 581 * General system settings like: uplink interval. 582 582 * LoRaWAN protocol & radio related command. 583 583 584 -They are same for all Dragino Device swhich support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:583 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 585 585 586 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>> url:http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]585 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 587 587 588 588 588 +* (% style="color:#037691" %)**Commands special design for PS-LB** 589 589 590 -== 3.3 Commands special design for PS-LB == 591 - 592 592 These commands only valid for PS-LB, as below: 593 593 594 594 595 -== =3.3.1 Set Transmit Interval Time ===593 +== 3.1 Set Transmit Interval Time == 596 596 597 597 598 598 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -620,7 +620,7 @@ 620 620 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 621 621 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 622 622 623 -== =3.3.2 Set Interrupt Mode ===621 +== 3.2 Set Interrupt Mode == 624 624 625 625 626 626 Feature, Set Interrupt mode for GPIO_EXIT. ... ... @@ -651,7 +651,7 @@ 651 651 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 652 652 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 653 653 654 -== =3.3.3Set the output time ===652 +== 3.3 Set the output time == 655 655 656 656 657 657 Feature, Control the output 3V3 , 5V or 12V. ... ... @@ -720,7 +720,7 @@ 720 720 * Example 5: Downlink Payload: 070301F4 **~-~-->** AT+12VT=500 721 721 * Example 6: Downlink Payload: 07030000 **~-~-->** AT+12VT=0 722 722 723 -== =3.3.4 Set the Probe Model ===721 +== 3.4 Set the Probe Model == 724 724 725 725 726 726 Users need to configure this parameter according to the type of external probe. In this way, the server can decode according to this value, and convert the current value output by the sensor into water depth or pressure value. ... ... @@ -750,6 +750,7 @@ 750 750 |AT +PROBE =0101|Set pressure transmitters mode, first type(A).|OK 751 751 |AT +PROBE =0000|Initial state, no settings.|OK 752 752 751 + 753 753 **Downlink Command: 0x08** 754 754 755 755 Format: Command Code (0x08) followed by 2 bytes. ... ... @@ -757,7 +757,7 @@ 757 757 * Example 1: Downlink Payload: 080003 **~-~-->** AT+PROBE=0003 758 758 * Example 2: Downlink Payload: 080101 **~-~-->** AT+PROBE=0101 759 759 760 -== =3.3.5=759 +== 3.5 Multiple collections are one uplink(Since firmware V1.1) == 761 761 762 762 763 763 Added AT+STDC command to collect the voltage of VDC_INPUT multiple times and upload it at one time. ... ... @@ -791,6 +791,7 @@ 791 791 OK 792 792 ))) 793 793 793 + 794 794 (% style="color:blue" %)**Downlink Command: 0xAE** 795 795 796 796 Format: Command Code (0x08) followed by 5 bytes. ... ... @@ -797,34 +797,107 @@ 797 797 798 798 * Example 1: Downlink Payload: AE 01 02 58 12** ~-~-->** AT+STDC=1,600,18 799 799 800 -= 4. Battery & PowerConsumption=800 += 4. Battery & how to replace = 801 801 802 - PS-LB-NAuses ER26500 + SPC1520batterypack. See below link for detail information about the batteryinfo and how to replace.802 +== 4.1 Battery Type == 803 803 804 - [[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 805 805 805 +PS-LB is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>https://www.dropbox.com/sh/w9l2oa3ytpculph/AAAPtt-apH4lYfCj-2Y6lHvQa?dl=0]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 806 806 807 - =5.OTAfirmwareupdate=807 +The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 808 808 809 +[[image:1675146710956-626.png]] 809 809 811 + 812 +Minimum Working Voltage for the PS-LB: 813 + 814 +PS-LB: 2.45v ~~ 3.6v 815 + 816 + 817 +== 4.2 Replace Battery == 818 + 819 + 820 +Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 821 + 822 +And make sure the positive and negative pins match. 823 + 824 + 825 +== 4.3 Power Consumption Analyze == 826 + 827 + 828 +Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 829 + 830 +Instruction to use as below: 831 + 832 +(% style="color:blue" %)**Step 1:**(%%) Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0>>https://www.dropbox.com/sh/zwex6i331j5oeq2/AACIMf9f_v2qsJ39CuMQ5Py_a?dl=0]] 833 + 834 +(% style="color:blue" %)**Step 2:**(%%) Open it and choose 835 + 836 +* Product Model 837 +* Uplink Interval 838 +* Working Mode 839 + 840 +And the Life expectation in difference case will be shown on the right. 841 + 842 +[[image:1675146895108-304.png]] 843 + 844 + 845 +The battery related documents as below: 846 + 847 +* [[Battery Dimension>>https://www.dropbox.com/s/ox5g9njwjle7aw3/LSN50-Battery-Dimension.pdf?dl=0]], 848 +* [[Lithium-Thionyl Chloride Battery datasheet, Tech Spec>>https://www.dropbox.com/sh/d4oyfnp8o94180o/AABQewCNSh5GPeQH86UxRgQQa?dl=0]] 849 +* [[Lithium-ion Battery-Capacitor datasheet>>https://www.dropbox.com/s/791gjes2lcbfi1p/SPC_1520_datasheet.jpg?dl=0]], [[Tech Spec>>https://www.dropbox.com/s/4pkepr9qqqvtzf2/SPC1520%20Technical%20Specification20171123.pdf?dl=0]] 850 + 851 +[[image:image-20230131145708-3.png]] 852 + 853 + 854 +=== 4.3.1 Battery Note === 855 + 856 + 857 +The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 858 + 859 + 860 +=== 4.3.2 Replace the battery === 861 + 862 + 863 +You can change the battery in the PS-LB.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 864 + 865 +The default battery pack of PS-LB includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 866 + 867 + 868 += 5. Remote Configure device = 869 + 870 +== 5.1 Connect via BLE == 871 + 872 + 873 +Please see this instruction for how to configure via BLE: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/]] 874 + 875 + 876 +== 5.2 AT Command Set == 877 + 878 + 879 + 880 += 6. OTA firmware update = 881 + 882 + 810 810 Please see this link for how to do OTA firmware update: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]] 811 811 812 812 813 -= 6. FAQ =886 += 7. FAQ = 814 814 815 -== 6.1 How to use AT Commandvia UARTto access device? ==888 +== 7.1 How to use AT Command to access device? == 816 816 817 817 818 818 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 819 819 820 820 821 -== 6.2 How to update firmware via UART port? ==894 +== 7.2 How to update firmware via UART port? == 822 822 823 823 824 824 See: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H1.LoRaSTv4baseHardware]] 825 825 826 826 827 -== 6.3 How to change the LoRa Frequency Bands/Region? ==900 +== 7.3 How to change the LoRa Frequency Bands/Region? == 828 828 829 829 830 830 You can follow the instructions for [[how to upgrade image>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]. ... ... @@ -831,13 +831,13 @@ 831 831 When downloading the images, choose the required image file for download. 832 832 833 833 834 -= 7. Order Info =907 += 8. Order Info = 835 835 836 836 837 837 [[image:image-20230131153105-4.png]] 838 838 839 839 840 -= 8. Packing Info =913 += 9. Packing Info = 841 841 842 842 843 843 (% style="color:#037691" %)**Package Includes**: ... ... @@ -851,7 +851,7 @@ 851 851 * Package Size / pcs : cm 852 852 * Weight / pcs : g 853 853 854 -= 9. Support =927 += 10. Support = 855 855 856 856 857 857 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
- image-20230225154759-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -468.9 KB - Content